Comparison of Different Locking Mechanisms in Total Hip Arthroplasty: Relative Motion between Cup and Inlay

The resulting inflammatory reaction to polyethylene (PE) wear debris, which may result in osteolysis, is still considered to be a main reason for aseptic loosening. In addition to the primary wear in hip joint replacements caused by head-insert articulation, relative motions between the PE liner and the metal cup may cause additional wear. In order to limit this motion, various locking mechanisms were used. We investigated three different locking mechanisms (Aesculap, DePuy, and Zimmer Biomet) to address the resulting relative motion between the acetabular cup and PE liner and the maximum disassembly force. A standardized setting with increasing load levels was used in combination with optically based three-dimensional measurements. In addition the maximum disassembly forces were evaluated according to the ASTM F1820-13 standard. Our data showed significant differences between the groups, with a maximum relative motion at the maximum load level (3.5 kN) of 86.5 ± 32.7 µm. The maximum axial disassembly force was 473.8 ± 94.6 N. The in vitro study showed that various locking mechanisms may influence cup-inlay stability.

[1]  T. Bormann,et al.  Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene. , 2019, Acta biomaterialia.

[2]  R. Sonntag,et al.  Backside wear in acetabular hip joint replacement. , 2019, Acta biomaterialia.

[3]  C. Peters,et al.  Ten‐year survivorship of primary total hip arthroplasty in patients 30 years of age or younger , 2018, The bone & joint journal.

[4]  R. Bitsch,et al.  Comparison of the stability of three fixation techniques between porous metal acetabular components and augments , 2018, Bone & joint research.

[5]  Kevin K. Chen,et al.  Early aseptic loosening of the Tritanium primary acetabular component with screw fixation , 2018, Arthroplasty today.

[6]  K. Delank,et al.  Backside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro , 2016, BioMed research international.

[7]  M. Teeter,et al.  Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners , 2016, Clinical orthopaedics and related research.

[8]  D. Beverland,et al.  Acetabular Liner Dissociation following Total Hip Arthroplasty: A Rare but Serious Complication That May Be Easily Misinterpreted in the Emergency Department , 2015, Case reports in emergency medicine.

[9]  P. Prokopovich Interactions between mammalian cells and nano- or micro-sized wear particles: physico-chemical views against biological approaches. , 2014, Advances in colloid and interface science.

[10]  S. Mears,et al.  Hip arthroplasty , 2012, The Lancet.

[11]  R. Bader,et al.  [Principles of tribological analysis of endoprostheses]. , 2012, Der Orthopade.

[12]  L. Whiteside,et al.  Minimal backside surface changes observed in retrieved acetabular liners. , 2011, The Journal of arthroplasty.

[13]  J. Jacobs,et al.  Biologic effects of implant debris. , 2009, Bulletin of the NYU hospital for joint diseases.

[14]  Harry A McKellop,et al.  The lexicon of polyethylene wear in artificial joints. , 2007, Biomaterials.

[15]  T. Wright,et al.  Impingement contributes to backside wear and screw-metallic shell fretting in modular acetabular cups. , 2007, The Journal of arthroplasty.

[16]  C. Bourgeault,et al.  Factors influencing the initial micromotion between polyethylene acetabular cups and titanium alloy shells. , 2006, The Journal of arthroplasty.

[17]  H. Rubash,et al.  The acetabular insert-metal backing interface: an additional source of polyethylene wear debris. , 2005, The Journal of arthroplasty.

[18]  A. Edidin,et al.  A literature review of the association between wear rate and osteolysis in total hip arthroplasty. , 2002, The Journal of arthroplasty.

[19]  W H Harris,et al.  Wear and periprosthetic osteolysis: the problem. , 2001, Clinical orthopaedics and related research.

[20]  C. V. White,et al.  Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement. , 1998, Journal of biomechanics.

[21]  D. Murray,et al.  Total hip replacement: indications for surgery and risk factors for failure , 1997, Annals of the rheumatic diseases.

[22]  R. Barrack,et al.  Pelvic Lysis and Polyethylene Wear at 5–8 Years in an Uncemented Total Hip , 1997, Clinical orthopaedics and related research.

[23]  L. Whiteside,et al.  Fixation of ultrahigh-molecular-weight polyethylene liners to metal-backed acetabular cups. , 1997, The Journal of arthroplasty.

[24]  J. Kabo,et al.  Wear of the polyethylene liner-metallic shell interface in modular acetabular components. An in vitro analysis. , 1996, The Journal of arthroplasty.

[25]  A. Greenwald,et al.  A comparison of the disassociation strength of modular acetabular components. , 1993, Clinical orthopaedics and related research.