Accurate estimation of the time-of-arrival of partial discharge pulses in cable systems in service

Accurate location of the origins of partial discharges in power cable systems, based on arrival times, is imperative for the identification and assessment of defects. This paper evaluates different time-of-arrival algorithms in order to determine which method yields most accurate location under different circumstances. These methods are based on trigger level, Akaike Information Criterion, energy criterion, Gabor's signal centroid and phase in frequency domain. Several criteria are defined by which the algorithms are evaluated. These criteria include the sensitivity to noise, pulse shape and effect of load impedance. The sensitivity of the methods upon varying these quantities is evaluated analytically and by means of simulations. Further, the methods are tested on a medium-voltage cable system by injecting PD pulses in a cable with one joint. Each algorithm is applied to the measured pulses and the resulting location is compared with the known joint location. From the results the energy criterion method and the phase method show the best performance.

[1]  Teri A. Crosby,et al.  How to Detect and Handle Outliers , 1993 .

[2]  Reinoud Sleeman,et al.  Robust automatic P-phase picking: an on-line implementation in the analysis of broadband seismogram recordings , 1999 .

[3]  Clifford H. Thurber,et al.  Automatic P-Wave Arrival Detection and Picking with Multiscale Wavelet Analysis for Single-Component Recordings , 2003 .

[4]  Dennis Gabor,et al.  Theory of communication , 1946 .

[5]  Yafei Zhou,et al.  Cost-effective on-line partial discharge of measurements for cables , 2006, IEEE Electrical Insulation Magazine.

[6]  Paaf Peter Wouters Online calibration of high-frequency partial discharge signals in three-phase belted power cables , 2005 .

[7]  van der,et al.  On-line detection and location of partial discharges in medium-voltage power cables , 2005 .

[8]  Jochen H Kurz,et al.  Strategies for reliable automatic onset time picking of acoustic emissions and of ultrasound signals in concrete. , 2005, Ultrasonics.

[9]  T. Leibfried,et al.  Algorithms for Automated Arrival Time Estimation of Partial Discharge Signals in Power Cables , 2007 .

[10]  Genshiro Kitagawa,et al.  A procedure for the modeling of non-stationary time series , 1978 .

[11]  M. S. Mashikian Partial discharge location as a diagnostic tool for power cables , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[12]  F. Kreuger,et al.  Partial discharge. XVIII. Errors in the location of partial discharges in high voltage solid dielectric cables , 1993, IEEE Electrical Insulation Magazine.

[13]  Hao Zhang,et al.  A novel wavelet transform technique for on-line partial discharge measurements. 1. WT de-noising algorithm , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.