Diode laser based photoacoustic humidity sensors

Abstract Various diode laser based photoacoustic (PA) systems applied in water vapour detection are presented. The dependence of the systems’ performance on the physical and chemical properties of the measured gas is discussed. It was found that the pressure dependence of the measured PA signal is different for amplitude and wavelength modulated lasers. This difference is explained. Linearity in a concentration range of more than four orders of magnitude in combination with typical accuracy of a few percentages was proved.

[1]  Photoacoustic multicomponent gas analysis using a Levenberg–Marquardt fitting algorithm , 1998 .

[2]  András Miklós,et al.  Detection of ammonia by photoacoustic spectroscopy with semiconductor lasers. , 2002, Applied optics.

[3]  Reinhard F. Bruch,et al.  Photoacoustic spectrometer for measuring light absorption by aerosol: instrument description , 1999 .

[4]  R. Niessner,et al.  Development of a photoacoustic gas sensor for in situ and on-line measurement of gaseous water and toluene† , 1998 .

[5]  M. Wolff,et al.  Photoacoustic spectrometer based on a DFB-diode laser , 2000 .

[6]  A. Miklós,et al.  Application of acoustic resonators in photoacoustic trace gas analysis and metrology , 2001 .

[7]  F. Durst,et al.  Fast trace humidity generation in the 0.1 ppm to 1000 ppm range with a two-stage dilution and mixing generator , 2000 .

[8]  Z. Bozóki,et al.  Evaluation of a photoacoustic detector for water vapor measurements under simulated tropospheric/lower stratospheric conditions. , 2001, Environmental Science and Technology.

[9]  A. Miklós,et al.  On the Possibility of Combining External Cavity Diode Laser with Photoacoustic Detector for High Sensitivity Gas Monitoring , 1997 .

[10]  András Miklós,et al.  Design and characterization of a windowless resonant photoacoustic chamber equipped with resonance locking circuitry , 1991 .

[11]  Zsolt Bor,et al.  Photoacoustic gas detection based on external cavity diode laser light sources , 1997 .

[12]  W. T. Donaldson A research program for identifying and measuring water pollutants. , 1973, International journal of environmental analytical chemistry.

[13]  P Hess,et al.  Effects of adsorption-desorption processes on the response time and accuracy of photoacoustic detection of ammonia. , 2001, Applied optics.

[14]  Zsolt Bor,et al.  A high-sensitivity, near-infrared tunable-diode-laser-based photoacoustic water-vapour-detection system for automated operation , 1999 .

[15]  Zsolt Bor,et al.  Near-Infrared Diode Laser Based Spectroscopic Detection of Ammonia: A Comparative Study of Photoacoustic and Direct Optical Absorption Methods , 2002, Applied spectroscopy.

[16]  Reinhard Niessner,et al.  Development of a Photoacoustic Trace Gas Sensor Based on Fiber-Optically Coupled NIR Laser Diodes , 1999 .