Cone-beam CT localization of internal target volumes for stereotactic body radiotherapy of lung lesions.

PURPOSE In this study, we investigate a technique of matching internal target volumes (ITVs) in four-dimensional (4D) simulation computed tomography (CT) to the composite target volume in free-breathing on-board cone-beam (CB) CT. The technique is illustrated by using both phantom and patient cases. METHODS AND MATERIALS A dynamic phantom with a target ball simulating respiratory motion with various amplitude and cycle times was used to verify localization accuracy. The dynamic phantom was scanned using simulation CT with a phase-based retrospective sorting technique. The ITV was then determined based on 10 sets of sorted images. The size and epicenter of the ITV identified from 4D simulation CT images and the composite target volume identified from on-board CBCT images were compared to assess localization accuracy. Similarly, for two clinical cases of patients with lung cancer, ITVs defined from 4D simulation CT images and CBCT images were compared. RESULTS For the phantom, localization accuracy between the ITV in 4D simulation CT and the composite target volume in CBCT was within 1 mm, and ITV was within 8.7%. For patient cases, ITVs on simulation CT and CBCT were within 8.0%. CONCLUSION This study shows that CBCT is a useful tool to localize ITV for targets affected by respiratory motion. Verification of the ITV from 4D simulation CT using on-board free-breathing CBCT is feasible for the target localization of lung tumors.

[1]  Suresh Senan,et al.  Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets. , 2005, International journal of radiation oncology, biology, physics.

[2]  James M Balter,et al.  Evaluation of the influence of breathing on the movement and modeling of lung tumors. , 2002, International journal of radiation oncology, biology, physics.

[3]  F. Yin,et al.  Image-guided procedures for intensity-modulated spinal radiosurgery. Technical note. , 2004, Journal of neurosurgery.

[4]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.

[5]  Uwe Oelfke,et al.  Linac-integrated 4D cone beam CT: first experimental results , 2006, Physics in medicine and biology.

[6]  John Wong,et al.  Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients. , 2004, International journal of radiation oncology, biology, physics.

[7]  F. Yin,et al.  Image-guided procedures for intensity-modulated spinal radiosurgery , 2004 .

[8]  Robert D Timmerman,et al.  A phase I trial of stereotactic body radiation therapy (SBRT) for liver metastases. , 2005, International journal of radiation oncology, biology, physics.

[9]  Masahiro Hiraoka,et al.  Treatment planning of stereotactic radiotherapy for solitary lung tumor. , 2005, International journal of radiation oncology, biology, physics.

[10]  S. Nill,et al.  Linac-integrated kV-cone beam CT: technical features and first applications. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[11]  W. O'Dell,et al.  Dose broadening due to target position variability during fractionated breath-held radiation therapy. , 2002, Medical physics.

[12]  Robert D Timmerman,et al.  Stereotactic body radiation therapy. , 2004, Current problems in cancer.

[13]  Robert D Timmerman,et al.  Extracranial radiosurgery (stereotactic body radiation therapy) for oligometastases. , 2006, Seminars in radiation oncology.

[14]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[15]  E. Kunieda,et al.  Small lung tumors: long-scan-time CT for planning of hypofractionated stereotactic radiation therapy--initial findings. , 2005, Radiology.

[16]  Radhe Mohan,et al.  Near simultaneous computed tomography image-guided stereotactic spinal radiotherapy: an emerging paradigm for achieving true stereotaxy. , 2003, International journal of radiation oncology, biology, physics.

[17]  Suresh Senan,et al.  Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer. , 2004, International journal of radiation oncology, biology, physics.

[18]  J. Debus,et al.  Correction of patient positioning errors based on in-line cone beam CTs: clinical implementation and first experiences , 2005, Radiation oncology.

[19]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[20]  Peter Munro,et al.  A quality assurance program for the on-board imager®. , 2006, Medical physics.

[21]  J. Beitler,et al.  Stereotactic body radiation therapy for nonmetastatic lung cancer: an analysis of 75 patients treated over 5 years. , 2006, International journal of radiation oncology, biology, physics.

[22]  Fang-Fang Yin,et al.  A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[23]  Suresh Senan,et al.  Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer. , 2005, International journal of radiation oncology, biology, physics.

[24]  M. Oldham,et al.  TH‐C‐ValB‐05: Rapid Low‐Dose 3D Image‐Guided Treatment Verification of Sites Prone to Respiratory Motion Using Breath‐Hold On‐Board Digital Tomosynthesis (DTS) , 2006 .

[25]  Robert D Timmerman,et al.  Extracranial stereotactic radiation delivery. , 2005, Seminars in radiation oncology.

[26]  Fang-Fang Yin,et al.  Physics and imaging for targeting of oligometastases. , 2006, Seminars in radiation oncology.

[27]  Robert D Timmerman,et al.  Stereotactic radiosurgery and stereotactic body radiation therapy: an overview of technical considerations and clinical applications. , 2006, Hematology/oncology clinics of North America.

[28]  Bruno Sorcini,et al.  Clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform). , 2006, Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique.

[29]  D. Song,et al.  Stereotactic body radiation therapy. Rationale, techniques, applications, and optimization. , 2004, Oncology.

[30]  E. Mendel,et al.  Phase I clinical evaluation of near-simultaneous computed tomographic image-guided stereotactic body radiotherapy for spinal metastases. , 2004, International journal of radiation oncology, biology, physics.

[31]  L Xing,et al.  Motion correction for improved target localization with on-board cone-beam computed tomography , 2006, Physics in medicine and biology.

[32]  T. Pan Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT. , 2005, Medical physics.