Exergy-based ecological optimisation for an endoreversible Brayton refrigeration cycle

The optimal exergy-based ecological performance of an endoreversible Brayton refrigeration cycle with the loss of heat-resistance is derived by taking into account an exergy-based ecological optimisation criterion as the objective function, which consists of maximising a function representing the best compromise between the exergy output rate and exergy loss rate (entropy generation rate and environment temperature product) of the refrigeration cycle. The expressions of the optimal cooling load, entropy generation rate and exergy-based ecological function of the cycle are derived by optimising the allocation of a fixed total heat exchanger inventory. The exergy-based ecologically optimum isentropic temperature ratio, coefficient of performance (COP), cooling load and entropy generation rate at maximum exergy-based ecological function point are also presented. Moreover, numerical examples are given to show that the effects of the temperature ratio of two reservoirs, the total heat exchanger inventory, and the temperature ratio between heat sink and surroundings on the optimal performance of the cycle.

[1]  Fengrui Sun,et al.  Cooling load density characteristics of an endoreversible variable‐temperature heat reservoir air refrigerator , 2002 .

[2]  A. Bejan Entropy generation minimization: The new thermodynamics of finite-size devices and finite-time processes , 1996 .

[3]  Fengrui Sun,et al.  Optimum Allocation of Heat Exchanger Inventory of Irreversible Air Refrigeration Cycles , 2002 .

[4]  Lingen Chen,et al.  A generalized model of a real refrigerator and its performance , 1997 .

[5]  Fengrui Sun,et al.  Ecological optimization for generalized irreversible Carnot refrigerators , 2005 .

[6]  Cha'o-Kuang Chen,et al.  Exergetic efficiency optimization for an irreversible Brayton refrigeration cycle , 2005 .

[7]  Fengrui Sun,et al.  Cooling-load density optimization for a regenerated air refrigerator , 2004 .

[8]  Fengrui Sun,et al.  Heat transfer effect on the specific cooling load of refrigerators , 1996 .

[9]  Fengrui Sun,et al.  Performance of heat-transfer irreversible regenerated Brayton refrigerators , 2001 .

[10]  Lingen Chen,et al.  Steady flow combined refrigeration cycle performance with heat leak , 1997 .

[11]  Lingen Chen,et al.  Finite Time Thermodynamic Optimization or Entropy Generation Minimization of Energy Systems , 1999 .

[12]  Fengrui Sun,et al.  Theoretical optimization of a regenerated air refrigerator , 2003 .

[13]  Yasin Ust,et al.  Performance Analysis of an Endoreversible Braysson Cycle Based on the Ecological Criterion , 2005 .