중형급 하이드라진 추력기에 장착되는 비충돌형 인젝터의 수류시험 및 성능평가
暂无分享,去创建一个
A water-flow test for acceptance verification is carried out for a nonimpinging-type injector prior to the design-performance verification of hydrazine thruster under development. The injector used in the experiment is to be equipped on the hydrazine thruster producing 70 N of nominal thrust at an inlet pressure of 24.6 kgf/cm 2 . It is observed that there exist varying characteristics of atomization among the injector-nozzle orifices caused by a fabrication error which can be judged from a microscopic standpoint. On the other hand, all of the injector orifices are placed within the design criteria in an injection-angle performance.