Reviewing effectiveness of ankle assessment techniques for use in robot-assisted therapy.

This article provides a comprehensive review of studies that investigated ankle assessment techniques to better understand those that can be used in the real-time monitoring of rehabilitation progress for implementation in conjunction with robot-assisted therapy. Seventy-six publications published between January 1980 and August 2013 were selected based on eight databases. They were divided into two main categories (16 qualitative and 60 quantitative studies): 13 goniometer studies, 18 dynamometer studies, and 29 studies about innovative techniques. A total of 465 subjects participated in the 29 quantitative studies of innovative measurement techniques that may potentially be integrated in a real-time monitoring device, of which 19 studies included less than 10 participants. Results show that qualitative ankle assessment methods are not suitable for real-time monitoring in robot-assisted therapy, though they are reliable for certain patients, while the quantitative methods show great potential. The majority of quantitative techniques are reliable in measuring ankle kinematics and kinetics but are usually available only for use in the sagittal plane. Limited studies determine kinematics and kinetics in all three planes (sagittal, transverse, and frontal) where motions of the ankle joint and the subtalar joint actually occur.

[1]  S. Tatsunami,et al.  Development and reliability of a standard rating system for outcome measurement of foot and ankle disorders II: interclinician and intraclinician reliability and validity of the newly established standard rating scales and Japanese Orthopaedic Association rating scale , 2005, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[2]  Peter H. Veltink,et al.  Ambulatory Assessment of Ankle and Foot Dynamics , 2007, IEEE Transactions on Biomedical Engineering.

[3]  Ian David Loram,et al.  Direct measurement of human ankle stiffness during quiet standing: the intrinsic mechanical stiffness is insufficient for stability , 2002, The Journal of physiology.

[4]  Zhiming Ji,et al.  Computational method to evaluate ankle postural stiffness with ground reaction forces. , 2004, Journal of rehabilitation research and development.

[5]  Li-Qun Zhang,et al.  Intelligent stretching of ankle joints with contracture/spasticity , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[6]  K. Landorf,et al.  A weightbearing technique for the measurement of ankle joint dorsiflexion with the knee extended is reliable. , 2009, Journal of science and medicine in sport.

[7]  T. Grindstaff,et al.  Reliability of three measures of ankle dorsiflexion range of motion. , 2012, International journal of sports physical therapy.

[8]  Qiyu Peng,et al.  Measurement of ankle spasticity in children with cerebral palsy using a manual spasticity evaluator , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  Self-assessed disability and functional performance in individuals with and without ankle instability: a case control study. , 2009, The Journal of orthopaedic and sports physical therapy.

[10]  M. Ochi,et al.  Evaluation of anterior talofibular ligament injury with stress radiography, ultrasonography and MR imaging , 2009, Skeletal Radiology.

[11]  G. Whitelaw,et al.  Functional bracing and rehabilitation of ankle fractures. , 1985, Clinical orthopaedics and related research.

[12]  Sheng Quan Xie,et al.  An iterative fuzzy controller for pneumatic muscle driven rehabilitation robot , 2011, Expert Syst. Appl..

[13]  Mingming Zhang,et al.  Effectiveness of robot-assisted therapy on ankle rehabilitation – a systematic review , 2013, Journal of NeuroEngineering and Rehabilitation.

[14]  A. Roy,et al.  Measurement of Human Ankle Stiffness Using the Anklebot , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[15]  M. Gorassini,et al.  Assessment of a portable device for the quantitative measurement of ankle joint stiffness in spastic individuals , 2012, Clinical Neurophysiology.

[16]  U. Sekir,et al.  Reliability of a Functional Test Battery Evaluating Functionality, Proprioception and Strength of the Ankle Joint , 2007, Turkish Journal of Medical Sciences.

[17]  R Adams,et al.  Measurement of passive ankle dorsiflexion: Procedure and reliability. , 1991, The Australian journal of physiotherapy.

[18]  D. Giansanti,et al.  Measurement device for ankle joint kinematic and dynamic characterisation , 2003, Medical and Biological Engineering and Computing.

[19]  K. Grafton,et al.  The intra and inter-rater reliability of a modified weight-bearing lunge measure of ankle dorsiflexion. , 2013, Manual therapy.

[20]  Comparing the reliability of a trigonometric technique to goniometry and inclinometry in measuring ankle dorsiflexion. , 2012, Gait & posture.

[21]  Jungwon Yoon,et al.  Reconfigurable ankle rehabilitation robot for various exercises , 2006 .

[22]  Robert E. Kearney,et al.  Quantitative, objective measurement of ankle dynamic stiffness: intrasubject reliability and intersubject variability , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  B. Petrisor,et al.  Measuring foot and ankle injury outcomes: common scales and checklists. , 2011, Injury.

[24]  Reliability of Isometric and Isokinetic Evaluations of Ankle Dorsi/Plantar Strength Among Older Adults , 1994 .

[25]  G. Sammarco,et al.  Rehabilitation Of The Foot And Ankle , 1995 .

[26]  U. Sekir,et al.  Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability. , 2008, European journal of physical and rehabilitation medicine.

[27]  P.H. Veltink,et al.  Estimation of Ankle Moment using Ambulatory Measurement of Ground Reaction Force and Movement of Foot and Ankle , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[28]  L. Kuhns,et al.  Ultrasound Examination of Ankle Injuries in Children , 2001, Journal of pediatric orthopedics.

[29]  I. Hunter,et al.  Dynamics of human ankle stiffness: variation with mean ankle torque. , 1982, Journal of biomechanics.

[30]  T. Kaminski,et al.  The Reliability and Validity of Ankle Inversion and Eversion Torque Measurements From the Kin Com II Isokinetic Dynamometer , 1995 .

[31]  RobRoy L Martin,et al.  Validity of the Foot and Ankle Ability Measure in athletes with chronic ankle instability. , 2008, Journal of athletic training.

[32]  K. Bennell,et al.  Intra-rater and inter-rater reliability of a weight-bearing lunge measure of ankle dorsiflexion. , 1998, The Australian journal of physiotherapy.

[33]  Kai-Ming Chan,et al.  A mechanical jig for measuring ankle supination and pronation torque in vitro and in vivo. , 2012, Medical engineering & physics.

[34]  Leslie T. Cooper,et al.  Assessment of Ankle Injuries , 2009, The Journal of school nursing : the official publication of the National Association of School Nurses.

[35]  K Aminian,et al.  Ambulatory measurement of ankle kinetics for clinical applications. , 2011, Journal of biomechanics.

[36]  M. Nyska,et al.  A Dynamic Ultrasound Examination for the Diagnosis of Ankle Syndesmotic Injury in Professional Athletes , 2009, The American journal of sports medicine.

[37]  Edward P. Mulligan Evaluation and management of ankle syndesmosis injuries. , 2011, Physical therapy in sport : official journal of the Association of Chartered Physiotherapists in Sports Medicine.

[38]  P. Morasso,et al.  Direct measurement of ankle stiffness during quiet standing: implications for control modelling and clinical application. , 2005, Gait & posture.

[39]  W. Duquet,et al.  The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: A systematic review , 2007, BMC musculoskeletal disorders.

[40]  T B Mascaro,et al.  Rehabilitation of the foot and ankle. , 1994, The Orthopedic clinics of North America.

[41]  M. Järvinen,et al.  A Performance Test Protocol and Scoring Scale for the Evaluation of An kle Injuries , 1994, The American journal of sports medicine.

[42]  Yun Dong,et al.  Reliable assessment of lower limb motor representations with fMRI: Use of a novel MR compatible device for real-time monitoring of ankle, knee and hip torques , 2008, NeuroImage.

[43]  S Siegler,et al.  Technique for in vivo measurement of the three‐dimensional kinematics and laxity characteristics of the ankle joint complex , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[44]  Toshiki Kobayashi,et al.  Design of a manual device to measure ankle joint stiffness and range of motion , 2011, Prosthetics and orthotics international.

[45]  Yasushi Akazawa,et al.  Quantitative measurement of spastic ankle joint stiffness using a manual device: a preliminary study. , 2010, Journal of biomechanics.

[46]  J. Hertel,et al.  Reliability and Sensitivity of the Foot and Ankle Disability Index in Subjects With Chronic Ankle Instability. , 2005, Journal of athletic training.

[47]  E H Wagner,et al.  Isokinetic testing of ankle strength in older adults: assessment of inter-rater reliability and stability of strength over six months. , 1994, Archives of physical medicine and rehabilitation.

[48]  P. Kim,et al.  Interrater and intrarater reliability in the measurement of ankle joint dorsiflexion is independent of examiner experience and technique used. , 2011, Journal of the American Podiatric Medical Association.

[49]  Darin A Padua,et al.  Validity and reliability of a new in vivo ankle stiffness measurement device. , 2007, Journal of biomechanics.

[50]  Robert E. Kearney,et al.  A bilateral electro-hydraulic actuator system to measure dynamic ankle joint stiffness during upright human stance , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[51]  L. Ploutz-Snyder,et al.  RELIABILITY OF KNEE AND ANKLE STRENGTH MEASURES IN AN OLDER ADULT POPULATION , 2006, Journal of strength and conditioning research.

[52]  K. Barker,et al.  Inter-tester comparison between visual estimation and goniometric measurement of ankle dorsiflexion , 1998 .

[53]  M. Saleh,et al.  In defence of gait analysis. Observation and measurement in gait assessment. , 1985, The Journal of bone and joint surgery. British volume.

[54]  Paul S Sung,et al.  Reliability of the intelligent stretching device for ankle stiffness measurements in healthy individuals. , 2010, Foot.

[55]  G. Riley Magnetic resonance imaging in the evaluation of sports injuries of the foot and ankle: a pictorial essay. , 2007, Journal of the American Podiatric Medical Association.

[56]  Clinical assessment of ankle injury outcomes: case scenario using the foot and ankle ability measure. , 2011, Journal of sport rehabilitation.

[57]  B. Waterman,et al.  The epidemiology of ankle sprains in the United States. , 2010, The Journal of bone and joint surgery. American volume.

[58]  R E Kearney,et al.  System identification of human ankle dynamics: intersubject variability and intrasubject reliability. , 1990, Clinical biomechanics.

[59]  Dynamic Evaluation of the Contact Characteristics and Three-Dimensional Motion for the Ankle Joint with Lateral Ligament Injuries , 2001 .

[60]  P. Huijing,et al.  Reproducibility of hand-held ankle dynamometry to measure altered ankle moment-angle characteristics in children with spastic cerebral palsy. , 2010, Clinical biomechanics.

[61]  K. Kaufman,et al.  Two‐dimensional digital video ankle motion analysis for assessment of function in the rat sciatic nerve model , 2007, Journal of the peripheral nervous system : JPNS.

[62]  W. Hop,et al.  Correlation between radiological assessment of acute ankle fractures and syndesmotic injury on MRI , 2011, Skeletal Radiology.

[63]  K. Rome,et al.  Ankle joint dorsiflexion measurement studies. A review of the literature. , 1996, Journal of the American Podiatric Medical Association.

[64]  J. George,et al.  Reconstruction of the anterior talofibular ligament for the treatment of the unstable ankle. , 1979, The Journal of bone and joint surgery. British volume.

[65]  C. Testerman,et al.  Evaluation of Ankle Instability Using the Biodex Stability System , 1999, Foot & ankle international.

[66]  M L Hull,et al.  Design and demonstration of a new instrumented spatial linkage for use in a dynamic environment: application to measurement of ankle rotations during snowboarding. , 2007, Journal of biomechanical engineering.

[67]  Accident compensation corporation. , 1983, The New Zealand medical journal.

[68]  Hylton B. Menz,et al.  Foot and Ankle Strength Assessment Using Hand-Held Dynamometry: Reliability and Age-Related Differences , 2009, Gerontology.

[69]  Shahid Hussain,et al.  An Adaptive Wearable Parallel Robot for the Treatment of Ankle Injuries , 2014, IEEE/ASME Transactions on Mechatronics.

[70]  M M Porter,et al.  Reliability of isokinetic ankle dorsiflexor strength measurements in healthy young men and women. , 1999, Scandinavian journal of rehabilitation medicine.

[71]  An MR-compatible device for the in situ assessment of isometric contractile performance of mouse hind-limb ankle flexors , 2003, Pflügers Archiv.

[72]  Shane Q. Xie,et al.  Design, Modeling and Control of an Ankle Rehabilitation Robot , 2009 .

[73]  I. Hunter,et al.  Dynamics of human ankle stiffness: variation with displacement amplitude. , 1982, Journal of biomechanics.

[74]  A. Lundberg,et al.  Ankle and Subtalar Kinematics Measured with Intracortical Pins during the Stance Phase of Walking , 2004, Foot & ankle international.

[75]  John H Hollman,et al.  Measurement of ankle dorsiflexion: a comparison of active and passive techniques in multiple positions. , 2011, Journal of sport rehabilitation.

[76]  S. Ohn,et al.  Biomechanical Assessment with Electromyography of Post-Stroke Ankle Plantar Flexor Spasticity , 2005, Yonsei medical journal.

[77]  J. Karlsson,et al.  Evaluation of ankle joint function: the use of a scoring scale , 1991 .

[78]  J. Keating,et al.  Measurements of ankle dorsiflexion in stroke subjects obtained using standardised dorsiflexion force. , 2000, The Australian journal of physiotherapy.

[79]  L. Blankevoort,et al.  Clinical evaluation of a dynamic test for lateral ankle ligament laxity , 2009, Knee Surgery, Sports Traumatology, Arthroscopy.

[80]  Reliability of Measuring Voluntary Strength and Isometric Twitch Properties in the Ankle Muscles of Very Old Adults , 1998 .

[81]  G. Moskowitz,et al.  Passive and active components of the internal moment developed about the ankle joint during human ambulation. , 1984, Journal of biomechanics.

[82]  Development of a fulcrum methodology to replicate the lateral ankle sprain mechanism and measure dynamic inversion speed , 2012, Sports biomechanics.

[83]  V. Mooney,et al.  Continuous passive motion with joint fractures and infections. , 1987, The Orthopedic clinics of North America.

[84]  R E Kearney,et al.  Quantitative assessment of ankle joint dynamics during recovery from injury. , 1990, Clinical biomechanics.

[85]  Hyung-Soon Park,et al.  Quantitative evaluations of ankle spasticity and stiffness in neurological disorders using manual spasticity evaluator. , 2011, Journal of rehabilitation research and development.

[86]  H. S. Davis,et al.  A Controlled Study , 1966 .

[87]  A. Çakcı,et al.  Reliability of isokinetic ankle inversion- and eversion-strength measurement in neutral foot position, using the Biodex dynamometer , 2004, Knee Surgery, Sports Traumatology, Arthroscopy.

[88]  K. Rome,et al.  A Reliability Study of the Universal Goniometer, Fluid Goniometer, and Electrogoniometer for the Measurement of Ankle Dorsiflexion , 1996, Foot & ankle international.

[89]  M. Bauer,et al.  Malleolar fractures: nonoperative versus operative treatment. A controlled study. , 1985, Clinical orthopaedics and related research.

[90]  S. Fonseca,et al.  Validity and reliability of clinical tests for assessing passive ankle stiffness. , 2011, Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil)).

[91]  Leon Bieber,et al.  Neurological rehabilitation. , 1992, Current opinion in neurology and neurosurgery.

[92]  N. Allington,et al.  Ankle Joint Range of Motion Measurements in Spastic Cerebral Palsy Children: Intraobserver and Interobserver Reliability and Reproducibility of Goniometry and Visual Estimation , 2002, Journal of pediatric orthopedics. Part B.

[93]  R. Vyas,et al.  Evaluation of the Validity of the Foot Function Index in Measuring Outcomes in Patients with Foot and Ankle Disorders , 2006, Foot & ankle international.

[94]  Alexis Schnitzler,et al.  Reliability of goniometric measurement of ankle dorsiflexion in hemiparetic patients , 2012 .

[95]  S. Hasson,et al.  Clinical assessment of ankle plantarflexor spasticity in adult patients after stroke: Inter-and intra-rater reliability of the Modified Tardieu Scale , 2013, Brain injury.

[96]  J. Darrah,et al.  Reliability of Passive Ankle Dorsiflexion Measurements in Children: Comparison of Universal and Biplane Goniometers , 1995 .

[97]  R. Burdett,et al.  Evidence of Validity for the Foot and Ankle Ability Measure (FAAM) , 2005, Foot & ankle international.

[98]  S. Tatsunami,et al.  Development and reliability of a standard rating system for outcome measurement of foot and ankle disorders I: development of standard rating system , 2005, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[99]  DE Wood,et al.  Biomechanical approaches applied to the lower and upper limb for the measurement of spasticity: A systematic review of the literature , 2005, Disability and rehabilitation.

[100]  M. Parnianpour,et al.  Reliability and validity of the Persian version of Foot and Ankle Ability Measure (FAAM) to measure functional limitations in patients with foot and ankle disorders. , 2010, Osteoarthritis and cartilage.

[101]  Hisashi Naito,et al.  Identification of Individual Muscle Length Parameters from Measurements of Passive Joint Moment Around the Ankle Joint , 2012 .

[102]  I. Campanini,et al.  What's the risk of using the Modified Ashworth Scale (MAS) to assess spasticity at the ankle? , 2011 .

[103]  H. Yack,et al.  A new device for assessing ankle dorsiflexion motion: reliability and validity. , 2011, The Journal of orthopaedic and sports physical therapy.

[104]  S. Lamb,et al.  Multi-item outcome measures for lateral ligament injury of the ankle: a structured review. , 2004, Journal of evaluation in clinical practice.

[105]  J. Lexell,et al.  Reproducibility of ankle dorsiflexor muscle strength measurements in individuals with post-polio syndrome , 2011 .

[106]  Volkan Patoglu,et al.  Design of a reconfigurable ankle rehabilitation robot and its use for the estimation of the ankle impedance , 2009, 2009 IEEE International Conference on Rehabilitation Robotics.

[107]  F. Krause,et al.  The use of weightbearing radiographs to assess the stability of supination-external rotation fractures of the ankle , 2010, Archives of Orthopaedic and Trauma Surgery.

[108]  P. Grenier,et al.  Ultrasono-anatomy of the ankle ligaments , 2005, Surgical and Radiologic Anatomy.

[109]  D. Downham,et al.  Ankle dorsiflexor muscle performance in healthy young men and women: reliability of eccentric peak torque and work measurements. , 2001, Journal of rehabilitation medicine.

[110]  P. Brukner,et al.  Sports ankle injuries - assessment and management. , 2010, Australian family physician.