A Prospective, In Vitro, Randomized Study to Compare Two Media for Donor Corneal Storage

Purpose: To determine if Cornisol is as effective as Optisol-GS as an intermediate-term corneal storage medium. Methods: A prospective, in vitro, randomized, partially masked study using paired donor corneas. Optical grade tissues not suitable for surgery were used. After performing baseline slit lamp evaluation, one tissue of each pair was randomly stored in Cornisol and the mate in Optisol-GS. Specular microscopy images were taken at baseline and repeated on days 3, 7, 10, and 14. The endothelial cell loss, endothelial cell density (ECD), coefficient of variance, and percentage hexagonality were recorded. On the 14th day, endothelial vitality was assessed histologically with alizarin red-S and trypan blue dual staining. The histology images were analyzed with ImageJ software and correlated with baseline specular findings. Results: A total of 32 pairs of cornea were included. One pair was excluded because of turbidity in both media. The mean donor age, death to preservation time, and baseline slit lamp characteristics were comparable between the 2 groups. The endothelial cell loss over 14 days was 17.4% in the Cornisol group and 15.7% in the Optisol-GS group (P = 0.83). The ECD, coefficient of variance, and percentage hexagonality were comparable between the groups at all measurement periods. There was no significant difference in the ECD calculated from histology pictures using ImageJ program (2345 ± 239 in Cornisol vs. 2393 ± 341 in Optisol-GS group; P = 0.22) and showed positive correlation using Pearson coefficient with baseline specular findings. Conclusions: Cornisol is as effective as Optisol-GS in preserving the donor corneal tissues for 14 days.

[1]  B. Banerjee National Programme for Control of Blindness , 2017 .

[2]  F. Price,et al.  Loteprednol Etabonate 0.5% Gel Vs. Prednisolone Acetate 1% Solution After Descemet Membrane Endothelial Keratoplasty: Prospective Randomized Trial , 2015, Cornea.

[3]  S. Debanne,et al.  Randomized, Prospective, Single-Masked Clinical Trial of Endothelial Keratoplasty Performance With 2 Donor Cornea 4°C Storage Solutions and Associated Chambers , 2015, Cornea.

[4]  Christopher G. Stoeger,et al.  Imaging and Quantification of Endothelial Cell Loss in Eye Bank Prepared DMEK Grafts Using Trainable Segmentation Software , 2014, Current eye research.

[5]  F. Javadi,et al.  Comparing quantitative and qualitative indices of the donated corneas maintained in Optisol-GS with those kept in Eusol-C , 2014, Cell and Tissue Banking.

[6]  S. Ferrari,et al.  A quantitative method to evaluate the donor corneal tissue quality used in a comparative study between two hypothermic preservation media , 2014, Cell and Tissue Banking.

[7]  Minh Vo,et al.  Donor Endothelial Specular Image Quality in Optisol GS and Life4˚C , 2013 .

[8]  R. Beck,et al.  Specular Microscopy Ancillary Study Methods for Donor Endothelial Cell Density Determination of Cornea Donor Study Images , 2006, Current eye research.

[9]  D. Hodge,et al.  In Vitro Comparison of Chen Medium and Optisol-GS Medium for Human Corneal Storage , 2000, Cornea.

[10]  R. Laing,et al.  A randomized, prospective, double-masked clinical trial of Optisol vs DexSol corneal storage media. , 1992, Archives of ophthalmology.

[11]  R. Laing,et al.  Optisol corneal storage medium. , 1991, American journal of ophthalmology.

[12]  M. Taylor,et al.  Dual staining of corneal endothelium with trypan blue and alizarin red S: importance of pH for the dye-lake reaction. , 1981, The British journal of ophthalmology.

[13]  G. Peyman,et al.  A new technique for the vital staining of the corneal endothelium. , 1976, Investigative ophthalmology.