Response of building systems with suspended floor slabs under dynamic excitations

Abstract Achieving a sustainable built environment that is less vulnerable to seismic hazard has been placed on the forefront of research pertaining to structure performance under earthquake loading. This resulted in a recent shift in the philosophy outlining structural performance during large magnitude earthquakes from preventing collapse to providing highly resilient structures that are easier to repair after a major event. The change in performance philosophy requires the development of new and innovative structural systems that are capable of performing as desired. Research and development of such structural systems has been gaining attention in recent years and have shown significant potential. This study extends previously conducted research on suspended structural systems and floor isolation systems by introducing the analytical solution of buildings with suspended floor slabs with replaceable energy dissipation elements are numerically analyzed under dynamic excitations. The proposed systems comprise of a steel frame with floor slabs suspended from the beams using steel cables. There are two models considered in this study, first in which the slabs are suspended using fixed hooks attached to the beams, thereby coupling the motion of the slab to its immediate neighbor bottom and top floor. In the second model, the slabs are suspended from the beams using rollers such that the motion of the slab is only coupled to the floor immediately below it. Controlled energy dissipation in the structure is realized through the use of steel links that are installed between the bottom face of the suspended slab and the floor beam underneath the slab. The orientation and quantity of the steel links as well as the slab to be suspended in a typical frame is determined such that an optimal performance of the system is achieved. Suspending selected floor slabs and tuning the links for energy dissipation can significantly reduce the damage to the main structural frame and nonstructural components of the system, in addition to reduction in floor response. Moreover, post-tensioned cables are installed adjacent to the links to provide self-centering capability to the slab and reduce its residual drift. The optimal performance of the two models is evaluated for various size frames and found to out-perform a conventional frame in case of large structures. The study concludes with a few important design implications regarding the proposed system.

[1]  H. Tajimi,et al.  Statistical Method of Determining the Maximum Response of Building Structure During an Earthquake , 1960 .

[2]  Satish Nagarajaiah,et al.  Structures with Semiactive Variable Stiffness Single/Multiple Tuned Mass Dampers , 2007 .

[3]  Ahsan Kareem,et al.  Performance of Multiple Mass Dampers Under Random Loading , 1995 .

[4]  S. E. Randall,et al.  Optimum Vibration Absorbers for Linear Damped Systems , 1981 .

[5]  G. B. Warburton,et al.  Optimum absorber parameters for simple systems , 1980 .

[6]  Gordon P. Warn,et al.  Seismic Performance and Sensitivity of Floor Isolation Systems in Steel Plate Shear Wall Structures , 2012 .

[7]  Masaru Abe,et al.  A Study on Pendulum Seismic Isolators for High-Rise Buildings , 2004 .

[8]  Yuzuru Yasui,et al.  SIMULTANEOUS HORIZONTAL AND VERTICAL VIBRATION TESTS OF THREE-DIMENSIONAL FLOOR ISOLATION SYSTEM , 1995 .

[9]  Hsiang-Chuan Tsai,et al.  Optimum tuned-mass dampers for minimizing steady-state response of support-excited and damped systems , 1993 .

[10]  Maria Q. Feng,et al.  Vibration Control of Tall Buildings Using Mega Subconfiguration , 1995 .

[11]  Lawrence A. Bergman,et al.  Optimal Distribution of Tuned Mass Dampers in Wind-Sensitive Structures , 1989 .

[12]  Michel Bruneau,et al.  Behavior of Bidirectional Spring Unit in Isolated Floor Systems , 2010 .

[13]  H. Yamaguchi,et al.  Fundamental characteristics of Multiple Tuned Mass Dampers for suppressing harmonically forced oscillations , 1993 .

[14]  Hussam Mahmoud,et al.  Hybrid Tuned Mass Damper and Isolation Floor Slab System Optimized for Vibration Control , 2015 .

[15]  Chi-Chang Lin,et al.  Protection of seismic structures using semi‐active friction TMD , 2009 .

[16]  J. W. Tedesco,et al.  Structural Dynamics: Theory and Applications , 1998 .

[17]  J. Ormondroyd Theory of the Dynamic Vibration Absorber , 1928 .

[18]  Chunxiang Li Performance of multiple tuned mass dampers for attenuating undesirable oscillations of structures under the ground acceleration , 2000 .

[19]  Michael C. Constantinou,et al.  Experimental Study of Ball-in-Cone Isolation System , 1997 .

[20]  Erik A. Johnson,et al.  "SMART" BASE ISOLATION SYSTEMS , 2000 .

[21]  Kiyoshi Kanai,et al.  Semi-empirical Formula for the Seismic Characteristics of the Ground , 1957 .

[22]  Matthew R. Eatherton,et al.  Large-scale cyclic and hybrid simulation testing and development of a controlled-rocking steel building system with replaceable fuses , 2010 .

[23]  Kyoung Sun Moon,et al.  Vertically distributed multiple tuned mass dampers in tall buildings: performance analysis and preliminary design , 2009 .

[24]  Masato Abe,et al.  Tuned mass dampers for structures with closely spaced natural frequencies , 1995 .

[25]  Akira Wada,et al.  Development of the core‐suspended isolation system , 2011 .