10,000-fold concentration increase of the biomarker cardiac troponin I in a reducing union microfluidic chip using cationic isotachophoresis.

This paper describes the preconcentration of the biomarker cardiac troponin I (cTnI) and a fluorescent protein (R-phycoerythrin) using cationic isotachophoresis (ITP) in a 3.9 cm long poly(methyl methacrylate) (PMMA) microfluidic chip. The microfluidic chip includes a channel with a 5× reduction in depth and a 10× reduction in width. Thus, the overall cross-sectional area decreases by 50× from inlet (anode) to outlet (cathode). The concentration is inversely proportional to the cross-sectional area so that as proteins migrate through the reductions, the concentrations increase proportionally. In addition, the proteins gain additional concentration by ITP. We observe that by performing ITP in a cross-sectional area reducing microfluidic chip we can attain concentration factors greater than 10,000. The starting concentration of cTnI was 2.3 μg mL⁻¹ and the final concentration after ITP concentration in the microfluidic chip was 25.52 ± 1.25 mg mL⁻¹. To the author's knowledge this is the first attempt at concentrating the cardiac biomarker cTnI by ITP. This experimental approach could be coupled to an immunoassay based technique and has the potential to lower limits of detection, increase sensitivity, and quantify different isolated cTnI phosphorylation states.

[1]  W. Kannel,et al.  Declining cardiovascular mortality. , 1984, Circulation.

[2]  B. Sobel,et al.  Thrombolysis, clot selectivity, and kinetics. , 1984, Circulation.

[3]  V. Dolnik,et al.  Large sample volume preseparation for trace analysis in isotachophoresis. , 1985, Journal of chromatography.

[4]  M. Abramowitz,et al.  Handbook of Mathematical Functions With Formulas, Graphs and Mathematical Tables (National Bureau of Standards Applied Mathematics Series No. 55) , 1965 .

[5]  D. A. Saville,et al.  The dynamics of electrophoresis , 1991 .

[6]  K. Šlais Model of isotachophoresis (displacement electrophoresis) in tapered capillaries , 1995, Electrophoresis.

[7]  H. Pratt,et al.  Electrophoretic mobilities of proteins and protein mixtures , 1995 .

[8]  R. Mentzer,et al.  Myofibrillar calcium sensitivity of isometric tension is increased in human dilated cardiomyopathies: role of altered beta-adrenergically mediated protein phosphorylation. , 1996, The Journal of clinical investigation.

[9]  C. Heeschen,et al.  Emergency room triage of patients with acute chest pain by means of rapid testing for cardiac troponin T or troponin I. , 1997, The New England journal of medicine.

[10]  I. Trayer,et al.  Phosphorylation-specific antibodies for human cardiac troponin-I. , 1998, European journal of biochemistry.

[11]  M. Bond,et al.  Protein kinase A (PKA)-dependent troponin-I phosphorylation and PKA regulatory subunits are decreased in human dilated cardiomyopathy. , 1999, Circulation.

[12]  Hugo A. Katus,et al.  Myocardial infarction redefined--a consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction. , 2000, European heart journal.

[13]  P. Burton,et al.  Effect of protein kinase A on calcium sensitivity of force and its sarcomere length dependence in human cardiomyocytes. , 2000, Cardiovascular research.

[14]  M. Welch,et al.  Heterogeneity in human cardiac troponin I standards. , 2000, Analytical biochemistry.

[15]  J. W. Schaeffer,et al.  ACC/AHA guidelines for the management of patients with unstable angina and non‐ST segment elevation myocardial infarction: Executive summary and recommendations , 2000, Circulation.

[16]  A. Jaffe,et al.  It's time for a change to a troponin standard. , 2000, Circulation.

[17]  Cheng S. Lee,et al.  On‐line coupling of capillary isoelectric focusing with transient isotachophoresis‐zone electrophoresis: A two‐dimensional separation system for proteomics , 2002, Electrophoresis.

[18]  Qifeng Xue,et al.  Sample pre-concentration by isotachophoresis in microfluidic devices. , 2002, Journal of chromatography. A.

[19]  Fred S Apple,et al.  Analytical performance of the i-STAT cardiac troponin I assay. , 2004, Clinica chimica acta; international journal of clinical chemistry.

[20]  A. Jaffe,et al.  Troponin: the biomarker of choice for the detection of cardiac injury , 2005, Canadian Medical Association Journal.

[21]  Prashanta Dutta,et al.  Isoelectric focusing in a poly(dimethylsiloxane) microfluidic chip. , 2005, Analytical chemistry.

[22]  L. Walker,et al.  A non-equilibrium isoelectric focusing method to determine states of phosphorylation of cardiac troponin I: identification of Ser-23 and Ser-24 as significant sites of phosphorylation by protein kinase C. , 2005, Journal of molecular and cellular cardiology.

[23]  Rajiv Bharadwaj,et al.  On-chip millionfold sample stacking using transient isotachophoresis. , 2006, Analytical chemistry.

[24]  H. Schneider,et al.  Performance evaluation and subsequent clinical experience with the Abbott Automated Architect STAT Troponin-I assay. , 2006, Clinical chemistry.

[25]  Massimo Leone,et al.  Integration between the Tele-Cardiology Unit and the central laboratory: methodological and clinical evaluation of point-of-care testing cardiac marker in the ambulance , 2006, Clinical chemistry and laboratory medicine.

[26]  T. Imasaka,et al.  Suppression of electroosmotic flow and its application to determination of electrophoretic mobilities in a poly(vinylpyrrolidone)-coated capillary. , 2006, Journal of chromatography. A.

[27]  F. Apple,et al.  Point-of-care i-STAT cardiac troponin I for assessment of patients with symptoms suggestive of acute coronary syndrome. , 2006, Clinical chemistry.

[28]  G. Armstrong,et al.  All troponins are not created equal , 2006, Internal medicine journal.

[29]  K. Rose,et al.  Metallic striped nanowires as multiplexed immunoassay platforms for pathogen detection. , 2006, Angewandte Chemie.

[30]  A. Singh,et al.  Integrated preconcentration SDS-PAGE of proteins in microchips using photopatterned cross-linked polyacrylamide gels. , 2006, Analytical chemistry.

[31]  Sarah B. Scruggs,et al.  Partial replacement of cardiac troponin I with a non-phosphorylatable mutant at serines 43/45 attenuates the contractile dysfunction associated with PKCepsilon phosphorylation. , 2006, Journal of molecular and cellular cardiology.

[32]  Fred S Apple,et al.  National Academy of Clinical Biochemistry and IFCC Committee for Standardization of Markers of Cardiac Damage Laboratory Medicine Practice Guidelines: Analytical issues for biochemical markers of acute coronary syndromes. , 2007, Circulation.

[33]  Juan G Santiago,et al.  Detection of 100 aM fluorophores using a high-sensitivity on-chip CE system and transient isotachophoresis. , 2007, Analytical chemistry.

[34]  S. Vowler,et al.  Prevalence, Characteristics and Outcomes of People Aged 65 Years and Over with an Incidental Rise in Cardiac Troponin I , 2007, Cardiology.

[35]  Noritada Kaji,et al.  Online preconcentration by transient isotachophoresis in linear polymer on a poly(methyl methacrylate) microchip for separation of human serum albumin immunoassay mixtures. , 2007, Analytical chemistry.

[36]  P. D. de Tombe,et al.  Frequency‐dependent myofilament Ca2+ desensitization in failing rat myocardium , 2007, The Journal of physiology.

[37]  Tomohisa Kawabata,et al.  “Electrokinetic Analyte Transport Assay” for α‐fetoprotein immunoassay integrates mixing, reaction and separation on‐chip , 2008, Electrophoresis.

[38]  V. Zabrouskov,et al.  Unraveling Molecular Complexity of Phosphorylated Human Cardiac Troponin I by Top Down Electron Capture Dissociation/Electron Transfer Dissociation Mass Spectrometry*S , 2008, Molecular & Cellular Proteomics.

[39]  A. Singer,et al.  Comparison of emergency department patient classification by point-of-care and central laboratory methods for cardiac troponin I. , 2008, American journal of clinical pathology.

[40]  Jasbir Singh,et al.  Discordance of cardiac troponin I assays on the point-of-care i-STAT and Architect assays from Abbott Diagnostics. , 2009, Clinica chimica acta; international journal of clinical chemistry.

[41]  J. Santiago,et al.  Effects of carbon dioxide on peak mode isotachophoresis: simultaneous preconcentration and separation. , 2009, Lab on a chip.

[42]  Clare E. Gallon Current techniques for the study of troponin I phosphorylation in human heart , 2009, Journal of Muscle Research and Cell Motility.

[43]  P. Boček,et al.  Recent progress in analytical capillary ITP , 2009, Electrophoresis.

[44]  Lei Zhang,et al.  Conjugation of biomolecules with magnetic protein microspheres for the assay of early biomarkers associated with acute myocardial infarction. , 2009, Analytical chemistry.

[45]  C. D. dos Remedios,et al.  The use of phosphate‐affinity SDS‐PAGE to measure the cardiac troponin I phosphorylation site distribution in human heart muscle , 2009, Proteomics. Clinical applications.

[46]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2009 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2009, Circulation.

[47]  W. Roberts,et al.  Performance characteristics of five cardiac Troponin I assays. , 2010, Clinica chimica acta; international journal of clinical chemistry.

[48]  Vincent T. Remcho,et al.  urface modification-assisted bonding of polymer-based microfluidic devices , 2009 .

[49]  F. Foret,et al.  Coupling of hydrodynamically closed large bore capillary isotachophoresis with electrospray mass spectrometry. , 2010, Journal of chromatography. A.