Radiochromic film dosimetry for clinical proton beams.

Depth doses and lateral profiles for proton beams with energies of 100-250 MeV were measured with a high-sensitivity GafChromic MD-55 film, which requires no post-irradiation development. The exposed MD-55 films were evaluated with the RIT 113 film dosimetry system. Depth doses measured with MD-55 film were compared with those obtained with a plane-parallel ionization chamber. The GafChromic film was found to be less sensitive at the distal edge for both modulated and unmodulated beams compared with an ionization chamber, however, the difference in penetration of the beam at the depth of 80-50% distal fall-off measured with this film and the ionization chamber is within 0.1-0.2 mm for studied beams. The lateral beam profiles measured with MD-55 film were in a good agreement with profiles obtained from Kodak XV-2 radiographic film, scanned with the Wellhofer densitometer. It is concluded that MD-55 film, with some limitations, is a useful detector for dosimetry measurements in a single proton beam and can be employed for verification dosimetry in multiple-beam radiation therapy.

[1]  M Goitein,et al.  Compensating for heterogeneities in proton radiation therapy. , 1984, Physics in medicine and biology.

[2]  Daniel W. Miller,et al.  Deduction of the air omega value in a therapeutic proton beam , 1995 .

[3]  E. McCullough,et al.  The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics. , 1994, Medical physics.

[4]  S. Shalaby,et al.  Irradiation of Polymers: Fundamentals and Technological Applications , 1996 .

[5]  Mohamad Al-Sheikhly,et al.  Radiochromic Solid-State Polymerization Reaction , 1996 .

[6]  M Moyers,et al.  Application of solid state detectors for dosimetry of therapeutic proton beams. , 1995, Medical physics.

[7]  S. C. Prasad,et al.  Clinical electron-beam dosimetry: report of AAPM Radiation Therapy Committee Task Group No. 25. , 1991, Medical physics.

[8]  R. Ramani,et al.  The use of radiochromic film in treatment verification of dynamic stereotactic radiosurgery. , 1994, Medical physics.

[9]  D. F. Lewis,et al.  Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beams , 1991 .

[10]  B. Coursey,et al.  Investigation of applicability of alanine and radiochromic detectors to dosimetry of proton clinical beams. , 1995, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[11]  S. Chiu‐Tsao,et al.  High-sensitivity GafChromic film dosimetry for 125I seed. , 1994, Medical physics.

[12]  Aapm A protocol for the determination of absorbed dose from high-energy photon and electron beams. , 1983, Medical physics.

[13]  B. A. Ludewigt,et al.  Instrumentation for Treatment of Cancer Using Proton and Light-Ion Beams , 1993 .

[14]  D. Miller,et al.  A review of proton beam radiation therapy. , 1995, Medical physics.

[15]  W. Mclaughlin,et al.  The response of plastic dosimeters to gamma rays and electrons at high absorbed dose rates , 1979 .