Age-of-the-air in rooms according to the environmental condition of temperature: A case study

Abstract The ventilation air in rooms is generally kept moving due to a constant difference in pressure. This gradient is generated through a general ventilation system (hybrid or mechanical), with minimum ventilation flow being established by the normative. However, there are cases in which, even if the established flows are fulfilled, certain indoor areas exhibit an excess or shortage of ventilation. The excess or deficit depends on the flow pattern that the air follows in the room, and its characterisation is possible using the indoor local and mean calculation of the age of the air. The flow pattern of air is conditioned by the energy transfer processes; therefore, analysis of air's behaviour under two extreme situations (summer and winter) was performed to compare the results with a previous isothermal model. For the development of this work, a double study (numerical and experimental) was conducted. The numerical calculations were developed using a CFD tool, which is notably useful for this type of research work.

[1]  H. Awbi Ventilation of buildings , 1873 .

[2]  R. D. Richtmyer,et al.  Difference methods for initial-value problems , 1959 .

[3]  Max H. Sherman Uncertainty in air flow calculations using tracer gas measurements , 1989 .

[4]  Mats Sjöberg,et al.  The use of moments for assessing air quality in ventilated rooms , 1983 .

[5]  Norhayati Mahyuddin,et al.  The spatial distribution of carbon dioxide in an environmental test chamber , 2010 .

[6]  Wei-Zhen Lu,et al.  Prediction of airflow and temperature field in a room with convective heat source , 1997 .

[7]  Jørn Toftum,et al.  New indoor environment chambers and field experiment offices for research on human comfort, health and productivity at moderate energy expenditure , 2004 .

[8]  M. Sandberg What is ventilation efficiency , 1981 .

[9]  M. Sherman Tracer-gas techniques for measuring ventilation in a single zone , 1990 .

[10]  Furio Cascetta,et al.  Assessment of velocity fields in the vicinity of rectangular exhaust hood openings , 2001 .

[11]  D. Wilcox Turbulence modeling for CFD , 1993 .

[12]  B. Olesen,et al.  Air distribution and ventilation effectiveness in an occupied room heated by warm air , 2012 .

[13]  C.-F. Gao,et al.  Evaluating the influence of openings configuration on natural ventilation performance of residential , 2011 .

[14]  Guohui Gan,et al.  Effective depth of fresh air distribution in rooms with single-sided natural ventilation , 2000 .

[15]  Hwataik Han,et al.  Tracer gas experiment for local mean ages of air from individual supply inlets in a space with multiple inlets , 2011 .

[16]  Lars Davidson,et al.  Calculation of age and local purging flow rate in rooms , 1987 .