A new smoothing procedure to reduce delivery segments for static MLC-based IMRT planning.

In the application of pixel-based intensity-modulated radiation therapy (IMRT) using the step-and-shoot delivery method, one major difficulty is the prolonged delivery time. In this study, we present an integrated IMRT planning system that involves a simple smoothing method to reduce the complexity of the beam profiles. The system consists of three main steps: (a) an inverse planning process based on a least-square dose-based cost function; (b) smoothing of the intensity maps; (c) reoptimization of the segment weights. Step (a) obtains the best plan with the lowest cost value using a simulated annealing optimization algorithm with discrete intensity levels. Step (b) takes the intensity maps obtained from (a) and reduces the complexity of the maps by smoothing the adjacent beamlet intensities. During this process each beamlet is assigned a structure index based on anatomical information. A smoothing update is applied to average adjacent beamlets with the same index. To control the quality of the plan, a predefined clinical protocol is used as an acceptance criterion. The smoothing updates that violate the criterion are rejected. After the smoothing process, the segment weights are reoptimized in step (c) to further improve the plan quality. Three clinical cases were studied using this system: a medulloblastoma, a prostate cancer, and an oropharyngeal carcinoma. While the final plans demonstrate a degradation of the original plan quality, they still meet the plan acceptance criterion. On the other hand, the segment numbers or delivery times are reduced by 40%, 20%, and 20% for the three cases, respectively.

[1]  R Mohan,et al.  Algorithms and functionality of an intensity modulated radiotherapy optimization system. , 2000, Medical physics.

[2]  C S Chui,et al.  Inverse planning algorithms for external beam radiation therapy. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[3]  J Yang,et al.  Smoothing intensity-modulated beam profiles to improve the efficiency of delivery. , 2001, Medical physics.

[4]  S. Webb,et al.  Inverse planning with constraints to generate smoothed intensity-modulated beams. , 1998, Physics in medicine and biology.

[5]  M. Alber,et al.  Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery. , 2001, Physics in medicine and biology.

[6]  S. Webb Optimisation of conformal radiotherapy dose distributions by simulated annealing. , 1989, Physics in medicine and biology.

[7]  D M Shepard,et al.  Direct aperture optimization: a turnkey solution for step-and-shoot IMRT. , 2002, Medical physics.

[8]  P. Xia,et al.  Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments. , 1998, Medical physics.

[9]  L Xing,et al.  Application of constrained least-squares techniques to IMRT treatment planning. , 2002, International journal of radiation oncology, biology, physics.

[10]  T Bortfeld,et al.  Optimized planning using physical objectives and constraints. , 1999, Seminars in radiation oncology.

[11]  Ying Xiao,et al.  The use of mixed-integer programming for inverse treatment planning with pre-defined field segments. , 2001, Physics in medicine and biology.