Online Vce measurement method for wear-out monitoring of high power IGBT modules
暂无分享,去创建一个
Stig Munk-Nielsen | Paul Thogersen | Szymon Beczkowski | Bjorn Rannestad | Angel Ruiz de Vega | Pramod Ghimre | S. Munk‐Nielsen | P. Thogersen | S. Bęczkowski | B. Rannestad | Pramod Ghimre
[1] Dawei Xiang,et al. An Industry-Based Survey of Reliability in Power Electronic Converters , 2011, IEEE Transactions on Industry Applications.
[2] T. Plum,et al. On-line Junction Temperature Measurement of CoolMOS Devices , 2007, 2007 7th International Conference on Power Electronics and Drive Systems.
[3] Mounira Berkani,et al. Ageing and Failure Modes of IGBT Modules in High-Temperature Power Cycling , 2011, IEEE Transactions on Industrial Electronics.
[4] Stig Munk-Nielsen,et al. Lifetime investigation of high power IGBT modules , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.
[5] Stig Munk-Nielsen,et al. Innovative measuring system for wear-out indication of high power IGBT modules , 2011, 2011 IEEE Energy Conversion Congress and Exposition.
[6] Seung-Ki Sul,et al. On-line estimation of IGBT junction temperature using on-state voltage drop , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).
[7] Mauro Ciappa,et al. Selected failure mechanisms of modern power modules , 2002, Microelectron. Reliab..
[8] Kristian Bonderup Pedersen,et al. Bond wire lift-off in IGBT modules due to thermomechanical induced stress , 2012, 2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG).
[9] C.P.W. Geurts,et al. Proceedings of the 13th international conference on wind engineering (ICWE13), July 10-15, 2011, Amsterdam , 2011 .