Different Blood Flow Models in Coronary Artery Diseases: Effects on hemodynamic parameters

Coronary arteries are medium-small caliber vessels, in which low shear rate values are encountered, where non-Newtonian blood effects cannot be neglected. This work aims to study a comparison between Newtonian and non-Newtonian blood behaviors in a cohort offorty-eight 3D patient-specific stenotic vessels (right (RCA), left (LAD) and circumflex (LCX) coronary artery) at different grades of stenosis. Numerical simulation was carried out by means of Computational Fluid Dynamics (CFD) Analysis to investigate the blood velocity and distribution of the shear stress indices at different times of the cardiac cycle. A statistical analysis was performed to have a prediction ofincrement or decrement ofthe various hemodynamic parameters. The results show that the non-Newtonian effects are mostly important in shear stress indices distributions.

[1]  Simulations of newtonian and non-newtonian flows in deformable tubes , 2013 .

[2]  Ciro Indolfi,et al.  Hemodynamically non-significant coronary artery stenosis: a predictive model , 2017 .

[3]  Christian Vergara,et al.  Computational Comparison Between Newtonian and Non-Newtonian Blood Rheologies in Stenotic Vessels , 2018 .

[4]  van de Fn Frans Vosse,et al.  The influence of the non-Newtonian properties of blood on the flow in large arteries: unsteady flow in a 90° curved tube , 1999 .

[5]  F. N. van de Vosse,et al.  The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation model. , 1999, Journal of biomechanics.

[6]  K. Rhee,et al.  Effects of surface geometry and non-newtonian viscosity on the flow field in arterial stenoses , 2009 .

[7]  D. Quemada,et al.  Rheology of concentrated disperse systems III. General features of the proposed non-newtonian model. Comparison with experimental data , 1978 .

[8]  Xi-yun Lu,et al.  Non-Newtonian effects of blood flow on hemodynamics in distal vascular graft anastomoses. , 2006, Journal of biomechanics.

[9]  Barbara M. Johnston,et al.  Non-Newtonian blood flow in human right coronary arteries: steady state simulations. , 2004, Journal of biomechanics.

[10]  Ciro Indolfi,et al.  Computational analysis of stenosis geometry effects on right coronary hemodynamics , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[11]  D. Saloner,et al.  Numerical analysis of flow through a severely stenotic carotid artery bifurcation. , 2002, Journal of biomechanical engineering.

[12]  Mehdi Jahangiri,et al.  Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis , 2015 .

[13]  M. J. Conley,et al.  The Prognostic Significance of 50% Coronary Stenosis in Medically Treated Patients with Coronary Artery Disease , 1980, Circulation.

[14]  M. Caruso,et al.  Computational analysis of aortic hemodynamics during total and partial extracorporeal membrane oxygenation and intra-aortic balloon pump support. , 2016, Acta of bioengineering and biomechanics.

[15]  H. Baieth Physical Parameters of Blood as a Non - Newtonian Fluid , 2008, International journal of biomedical science : IJBS.

[16]  Mark W. Siebert,et al.  Newtonian and Non-Newtonian Blood Flow over a Backward- Facing Step - A Case Study , 2009 .

[17]  J. Tarbell,et al.  Influence of non-Newtonian behavior of blood on flow in an elastic artery model. , 1996, Journal of biomechanical engineering.