Odour emissions from tunnel-ventilated broiler sheds: case study of nine Queensland farms

Odour emission rates were measured from nine tunnel-ventilated broiler farms in south-eastern Queensland, Australia. At one farm, odour emission rates were measured over two sequential batches approximately weekly, while at the remaining farms, odour emission rates were measured just before the first pickup (around Day 35 of the batch) when bird liveweight was greatest and peak odour emission rates were expected. Odour samples were analysed using dynamic olfactometry (to AS/NZS 4323.3:2001), and an artificial olfaction system was used to continuously monitor odour emission rates at one farm. Odour emission rates ranged from 330 to 2960 ou/s per 1000 birds and from 0.19 to 2.12 ou/s.kg, with a significant amount of variability observed throughout the batch and throughout each sampling day. While the wide range in odour emission rates was primarily due to changes in bird liveweight and ventilation requirements, other factors were also involved. The artificial olfaction system proved useful for quantifying the range and variability of odour emission rates, especially when olfactometry analysis was impractical.

[1]  D. H. O'Neill,et al.  A review of the control of odour nuisance from livestock buildings: Part 3, properties of the odorous substances which have been identified in livestock wastes or in the air around them , 1992 .

[2]  L. Zeller,et al.  Implementation of an electronic nose for continuous odour monitoring in a poultry shed , 2008 .

[3]  B. Grant,et al.  Emissions of volatile organic compounds originating from UK livestock agriculture , 2004 .

[4]  D. Duperouzel,et al.  Assessment of permeable covers for odour reduction in piggery effluent ponds. 1. Laboratory-scale trials. , 2006, Bioresource technology.

[5]  S. Schiffman,et al.  Quantification of odors and odorants from swine operations in North Carolina , 2001 .

[6]  Saqib Mukhtar,et al.  A Review of Literature Concerning Odors, Ammonia, and Dust from Broiler Production Facilities: 1. Odor Concentrations and Emissions , 2004 .

[7]  Saqib Mukhtar,et al.  A Review of Literature Concerning Odors, Ammonia, and Dust from Broiler Production Facilities: 2. Flock and House Management Factors , 2004 .

[8]  G. Ayoko,et al.  Comparison of odour emission rates measured from various sources using two sampling devices. , 2009, Bioresource technology.

[9]  V A Dodd,et al.  Odour and ammonia emissions from intensive pig units in Ireland. , 2006, Bioresource technology.

[10]  S. Hoff,et al.  Characterization of volatile organic compounds and odorants associated with swine barn particulate matter using solid-phase microextraction and gas chromatography-mass spectrometry-olfactometry. , 2006, Journal of chromatography. A.

[11]  Godwin A. Ayoko,et al.  Comparison of emission rate values for odour and odorous chemicals derived from two sampling devices , 2009 .

[12]  Theo Demmers,et al.  Commercial-scale Studies of the Effect of Broiler-protein Intake on Aerial Pollutant Emissions , 2002 .