Flow-velocity Microsensors Based on Semiconductor Fieldeffect Structures

Abstract : A time-of-flight-type flow-velocity sensor employing the in-situ electrochemically generation of ion-tracers is developed. The sensor consists of an ion generator and two downstream-placed pH-sensitive Ta 2 O 5 -gate ISFETs (ion-sensitive field-effect transistor) that detect generated H + - or OH - -ions. The results of the developed flow-velocity sensor under different modes of ion generation are presented and discussed. By applying this ISFET-array, the time of flight, and consequently, the flow velocity can be accurately evaluated using the shift of the response curve of the respective ISFETs in the array along the time scale. A good linearity between the measured flow velocity with the ISFET-array and the delivered flow rate of the pump is observed. In addition, a possibility of flow-velocity measurements by means of a LAPS (light-addressable potentiometric sensor) is firstly demonstrated. Keywords: Flow-velocity sensor, time of flight, ISFET, LAPS, pH, ion generation. Introduction

[1]  Walter Lang,et al.  Thermal flow sensor for liquids and gases based on combinations of two principles , 1999 .

[2]  Michael J. Schöning,et al.  Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS? , 2001 .

[3]  Takashi Kobayashi,et al.  The Prandtl micro flow sensor (PMFS): a novel silicon diaphragm capacitive sensor for flow velocity measurement , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[4]  Gerald Urban,et al.  Wide range semiconductor flow sensors , 2000 .

[5]  Takashi Kobayashi,et al.  The Prandtl micro flow sensor (PMFS) : a novel silicon diaphragm capacitive sensor for flow-velocity measurement , 1998 .

[6]  J. W. Schultze,et al.  Multi-parameter detection of (bio-)chemical and physical quantities using an identical transducer principle , 2003 .

[7]  Jan H. J. Fluitman,et al.  Multi-parameter detection in fluid flows , 1995 .

[8]  Hiroshi Iwasaki,et al.  Constant-Current-Mode LAPS (CLAPS) for the Detectionof Penicillin , 2001 .

[9]  Hans Lueth,et al.  Novel concept for flow-rate and flow-direction determination by means of pH-sensitive ISFETs , 2001, MOEMS-MEMS.

[10]  W. Sansen,et al.  Electrochemical time of flight flow sensor , 2002 .

[11]  Yu-Chong Tai,et al.  MEMS flow sensors for nano-fluidic applications , 2000, Proceedings IEEE Thirteenth Annual International Conference on Micro Electro Mechanical Systems (Cat. No.00CH36308).

[12]  Abdul Jabbar N. Khalifa,et al.  On the verification of a hydrogen bubble flow meter used for monitoring flow rates in thermosyphon solar water heaters , 1998 .

[13]  Michael J. Schöning,et al.  Chemical sensor as physical sensor: ISFET-based flow-velocity, flow-direction and diffusion-coefficient sensor , 2003 .

[14]  Jens Anders Branebjerg,et al.  Microfluidics-a review , 1993 .

[15]  Gijsbertus J.M. Krijnen,et al.  A micromachined pressure/flow-sensor , 1999 .

[16]  Nam-Trung Nguyen,et al.  Micromachined flow sensors—a review , 1997, Flow Measurement and Instrumentation.