Development and performance verification of a TPC polarimeter for high energy x-rays

We present the first application of a time projection chamber polarimeter to measure high energy X-ray polarization above 10 keV. The polarimeter is designed based on the PRAXyS soft X-ray polarimeter. The sealed gas is changed to a gas mixture of 60% argon and 40% dimethyl ether at 1 atm to be sensitive to high energy X-rays. The polarimeter performance is verified with linearly polarized, monochromatic X-rays at a synchrotron radiation facility, KEK Photon Factory BL-14A. The measured modulation factors are 42.4 ± 0.6%, 50.4 ± 0.6%, and 55.0 ± 0.6% at 12, 14, and 16 keV, respectively, and the measured polarization angles are consistent with the expected values at all energies.

[1]  T. Tamagawa,et al.  A convolutional neural network approach for reconstructing polarization information of photoelectric X-ray polarimeters , 2019, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[2]  T. Tamagawa,et al.  An optimized photoelectron track reconstruction method for photoelectric X-ray polarimeters , 2018 .

[3]  Andrea Neviani,et al.  Design and results from the APV25, a deep sub-micron CMOS front-end chip for the CMS tracker , 2001 .

[4]  Martin C. Weisskopf,et al.  The Imaging X-ray Polarimetry Explorer (IXPE) , 2016, Astronomical Telescopes + Instrumentation.

[5]  Shigeru Okabe,et al.  Generalized semiempirical equations for the extrapolated range of electrons , 1972 .

[6]  J. F. Toledo,et al.  Development of the scalable readout system for micro-pattern gas detectors and other applications , 2013 .

[7]  T. Tamagawa,et al.  Development of the GEM-TPC X-ray Polarimeter with the Scalable Readout System , 2018 .

[8]  J. E. Hill,et al.  Performance of the PRAXyS X-Ray Polarimeter , 2016, 1610.06677.

[9]  K. Hayashida,et al.  How Linearly Polarized Is the X-Ray Beam from the X-Ray Generator? , 1997 .

[10]  S. Barthelmy,et al.  Design and Performance of the X-ray polarimeter X-Calibur , 2014, 1412.6457.

[11]  Keith Jahoda,et al.  X-ray polarimetry with a micropattern TPC , 2007 .

[12]  H. Tawara,et al.  Development of Thick-foil and Fine-pitch GEMs with a Laser Etching Technique , 2009, 0910.0406.

[13]  M. Kiss,et al.  The PoGO+ view on Crab off-pulse hard X-ray polarization , 2018, 1802.07775.

[14]  Takashi Okajima,et al.  The x-ray advanced concepts testbed (XACT) sounding rocket payload , 2012, Other Conferences.

[15]  Hirohisa Sakurai,et al.  Hard X-ray polarization measured with a Compton polarimeter at synchrotron radiation facility , 2004 .

[16]  K. Long,et al.  A precision measurement of the X-ray polarization of the Crab Nebula without pulsar contamination. , 1978 .

[17]  E. Costa,et al.  An efficient photoelectric X-ray polarimeter for the study of black holes and neutron stars , 2001, Nature.