eBP: A Wearable System For Frequent and Comfortable Blood Pressure Monitoring From User's Ear

Frequent blood pressure (BP) assessment is key to the diagnosis and treatment of many severe diseases, such as heart failure, kidney failure, hypertension, and hemodialysis. Current "gold-standard'' BP measurement techniques require the complete blockage of blood flow, which causes discomfort and disruption to normal activity when the assessment is done repetitively and frequently. Unfortunately, patients with hypertension or hemodialysis often have to get their BP measured every 15 minutes for a duration of 4-5 hours or more. The discomfort of wearing a cumbersome and limited mobility device affects their normal activities. In this work, we propose a device called eBP to measure BP from inside the user's ear aiming to minimize the measurement's impact on users' normal activities while maximizing its comfort level. eBP has 3 key components: (1) a light-based pulse sensor attached on an inflatable pipe that goes inside the ear, (2) a digital air pump with a fine controller, and (3) a BP estimation algorithm. In contrast to existing devices, eBP introduces a novel technique that eliminates the need to block the blood flow inside the ear, which alleviates the user's discomfort. We prototyped eBP custom hardware and software and evaluated the system through a comparative study on 35 subjects. The study shows that eBP obtains the average error of 1.8 mmHg and -3.1 mmHg and a standard deviation error of 7.2 mmHg and 7.9 mmHg for systolic (high-pressure value) and diastolic (low-pressure value), respectively. These errors are around the acceptable margins regulated by the FDA's AAMI protocol, which allows mean errors of up to 5 mmHg and a standard deviation of up to 8 mmHg.

[1]  Brian Taylor,et al.  Applications of direct-to-consumer hearing devices for adults with hearing loss: a review , 2017, Clinical interventions in aging.

[2]  Daniel E Weiner,et al.  Blood Pressure Management in Hemodialysis Patients: What We Know And What Questions Remain , 2017, Seminars in dialysis.

[3]  Christian Holz,et al.  Glabella: Continuously Sensing Blood Pressure Behavior using an Unobtrusive Wearable Device , 2017, Proc. ACM Interact. Mob. Wearable Ubiquitous Technol..

[4]  R W Barnes,et al.  An index of healing in below-knee amputation: leg blood pressure by Doppler ultrasound. , 1976, Surgery.

[5]  Fernando Nobre,et al.  Ambulatory Blood Pressure Monitoring: Five Decades of More Light and Less Shadows , 2016, Arquivos brasileiros de cardiologia.

[6]  E. O’Brien,et al.  Ambulatory blood pressure monitoring in the management of hypertension , 2003, Heart.

[7]  Sohan Singh Hayreh,et al.  Systemic arterial blood pressure and the eye , 1996 .

[8]  Gwanggil Jeon,et al.  On Using Maximum a Posteriori Probability Based on a Bayesian Model for Oscillometric Blood Pressure Estimation , 2013, Sensors.

[9]  Y Epstein,et al.  Calculation of mean arterial pressure during exercise as a function of heart rate. , 1995, Applied human science : journal of physiological anthropology.

[10]  Qi Zhang,et al.  Validation of the noninvasive assessment of central blood pressure by the SphygmoCor and Omron devices against the invasive catheter measurement. , 2011, American journal of hypertension.

[11]  E. O’Brien,et al.  State of the market. A review of ambulatory blood pressure monitoring devices. , 1995, Hypertension.

[12]  ノーラン,ジェームズ・エイ,et al.  Method and apparatus for continuous non-invasive monitoring of blood pressure parameters , 1996 .

[13]  T. Pickering,et al.  Principles and techniques of blood pressure measurement. , 2002, Cardiology clinics.

[14]  Natalya Kizilova,et al.  Review of emerging methods and techniques for arterial pressure and flow waves acquisition and analyses , 2018 .

[15]  M. Todorović,et al.  Evaluation of dynamic performance in liquid-filled catheter systems for measuring invasive blood pressure , 1996, International journal of clinical monitoring and computing.

[16]  Bruce D. Johnson,et al.  Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials , 2015, Physiological reports.

[17]  Yuan-Ting Zhang,et al.  Multi-Wavelength Photoplethysmography Enabling Continuous Blood Pressure Measurement With Compact Wearable Electronics , 2019, IEEE Transactions on Biomedical Engineering.

[18]  Paul Wieneke,et al.  Evaluation of the performance of a wrist blood pressure measuring device with a position sensor compared to ambulatory 24-hour blood pressure measurements. , 2002, American journal of hypertension.

[19]  G. V. van Montfrans,et al.  Oscillometric blood pressure measurement: progress and problems , 2001, Blood pressure monitoring.

[20]  Jan A Staessen,et al.  White-coat hypertension: new insights from recent studies. , 2013, Hypertension.

[21]  N. Basso,et al.  Palpatory Method Used to Identify the Recurrent Laryngeal Nerve during Thyroidectomy , 2000, World Journal of Surgery.

[22]  Y.T. Zhang,et al.  Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[23]  平原英昭 Blood pressure measuring apparatus and blood pressure measuring method , 2011 .

[24]  L. Geddes,et al.  Characterization of the oscillometric method for measuring indirect blood pressure , 2006, Annals of Biomedical Engineering.

[25]  Meir Nitzan,et al.  Automatic noninvasive measurement of systolic blood pressure using photoplethysmography , 2009, Biomedical engineering online.

[26]  Marcel C M Rutten,et al.  Toward noninvasive blood pressure assessment in arteries by using ultrasound. , 2011, Ultrasound in medicine & biology.

[27]  Yutaka Imai,et al.  European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement , 2003, Journal of hypertension.

[28]  Ryan J. Halter,et al.  Amulet: An Energy-Efficient, Multi-Application Wearable Platform , 2016, SenSys.

[29]  J. Hahn,et al.  Smartphone-based blood pressure monitoring via the oscillometric finger-pressing method , 2018, Science Translational Medicine.

[30]  Sridhar Madala,et al.  Noninvasive blood pressure measurement in mice using pulsed Doppler ultrasound. , 2003, Ultrasound in medicine & biology.

[31]  A. J. Dunning,et al.  Accuracy of auscultatory blood pressure measurement with a long cuff. , 1987, British medical journal.

[32]  G. Drzewiecki,et al.  Theory of the oscillometric maximum and the systolic and diastolic detection ratios , 2006, Annals of Biomedical Engineering.

[33]  Yan Li,et al.  Blood Pressure Measurement Anno 2016 , 2017, American journal of hypertension.

[34]  Farnoush Banaei Kashani,et al.  A Lightweight and Inexpensive In-ear Sensing System For Automatic Whole-night Sleep Stage Monitoring , 2016, SenSys.

[35]  Voicu Groza,et al.  Blood pressure estimation using maximum slope of oscillometric pulses , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[36]  Abi Berger,et al.  Oscillatory Blood Pressure Monitoring Devices , 2001, BMJ : British Medical Journal.

[37]  Steven W. Smith,et al.  The Scientist and Engineer's Guide to Digital Signal Processing , 1997 .

[38]  G. James,et al.  Measuring arterial blood pressure in humans: Auscultatory and automatic measurement techniques for human biological field studies , 2018, American journal of human biology : the official journal of the Human Biology Council.

[39]  Ramakrishna Mukkamala,et al.  Patient-Specific Oscillometric Blood Pressure Measurement , 2016, IEEE Transactions on Biomedical Engineering.

[40]  B. Gaszner,et al.  Invasive validation of a new oscillometric device (Arteriograph) for measuring augmentation index, central blood pressure and aortic pulse wave velocity , 2010, Journal of hypertension.

[41]  B. Morgenstern,et al.  Human blood pressure determination by sphygmomanometry. , 1993, Circulation.

[42]  Jens Eckstein,et al.  P441Use of a smartphone camera to estimate systolic blood pressure compared to standard oscillometric blood pressure measurement - a prospective trial , 2017 .

[43]  M. Dauzat,et al.  Validation of a fully automatic photoplethysmographic device for toe blood pressure measurement. , 2010, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[44]  Maram Maheedhar,et al.  Cuff-less PPG based continuous blood pressure monitoring - A smartphone based approach , 2016, EMBC.

[45]  D S Sumner,et al.  Toe blood pressure. A valuable adjunct to ankle pressure measurement for assessing peripheral arterial disease. , 1983, The Journal of cardiovascular surgery.

[46]  G. R. Ramesh Prasad,et al.  Ambulatory blood pressure monitoring in solid organ transplantation , 2012, Clinical transplantation.

[47]  A. Sapiński Standard algorithm of blood-pressure measurement by the oscillometric method , 2006, Medical and Biological Engineering and Computing.

[48]  John A. Albertini,et al.  Deafness and Hearing Loss , 2010 .

[49]  Mahboob Rahman,et al.  Blood pressure measurement: clinic, home, ambulatory, and beyond. , 2012, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[50]  Donald W McKay,et al.  Measuring blood pressure: A call to bare arms? , 2008, Canadian Medical Association Journal.

[51]  Hiroshi Kanai,et al.  One of the problems in the measurement of blood pressure by catheter-insertion: Wave reflection at the tip of the catheter , 1970, Medical and biological engineering.

[52]  D. Chestnut,et al.  Continuous Invasive Blood Pressure and Cardiac Output Monitoring during Cesarean Delivery: A Randomized, Double-Blind Comparison of Low-dose versus High-dose Spinal Anesthesia with Intravenous Phenylephrine or Placebo Infusion , 2010 .

[53]  A. Adji,et al.  Eye Clinic as a Potential Site to Measure Blood Pressure. , 2018, American journal of hypertension.

[54]  J. Stoker,et al.  The Department of Health and Human Services. , 1999, Home healthcare nurse.

[55]  Kirk H. Shelley,et al.  Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[56]  Nitish V. Thakor,et al.  Describing the Nonstationarity Level of Neurological Signals Based on Quantifications of Time–Frequency Representation , 2007, IEEE Transactions on Biomedical Engineering.

[57]  Ronald R. Coifman,et al.  Entropy-based algorithms for best basis selection , 1992, IEEE Trans. Inf. Theory.

[58]  Sumner Ds,et al.  Toe blood pressure. A valuable adjunct to ankle pressure measurement for assessing peripheral arterial disease. , 1983 .

[59]  J. Hobbs,et al.  Ankle systolic pressure measurements in arterial disease affecting the lower extremities , 1969, The British journal of surgery.

[60]  M. Bhaskaran,et al.  Palpatory Method of Measuring Diastolic Blood Pressure , 2010, Journal of anaesthesiology, clinical pharmacology.

[61]  Eoin O'Brien,et al.  Demise of the mercury sphygmomanometer and the dawning of a new era in blood pressure measurement. , 2003, Blood pressure monitoring.

[62]  N. Kayalvizhi,et al.  Measurement of Pulse Transit Time (PTT) Using Photoplethysmography , 2017 .

[63]  D. Westenskow,et al.  Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure , 1997, Medical and Biological Engineering and Computing.

[64]  F E Block,et al.  Ankle blood pressure measurement, an acceptable alternative to arm measurements , 1996, International journal of clinical monitoring and computing.

[65]  理 祖父江,et al.  Blood pressure management in hemodialysis patients , 2013 .

[66]  Zhi-Hong Mao,et al.  Cuff-free blood pressure estimation using pulse transit time and heart rate , 2014, 2014 12th International Conference on Signal Processing (ICSP).

[67]  Shwetak N. Patel,et al.  Seismo: Blood Pressure Monitoring using Built-in Smartphone Accelerometer and Camera , 2018, CHI.

[68]  D. P. Mandic,et al.  The In-the-Ear Recording Concept: User-Centered and Wearable Brain Monitoring , 2012, IEEE Pulse.

[69]  Gianfranco Parati,et al.  Self blood pressure monitoring at home by wrist devices: a reliable approach? , 2002, Journal of hypertension.

[70]  Changyun Wen,et al.  Statistical analysis of blood pressure measurement errors by oscillometry during surgical operations , 2011, Blood pressure monitoring.

[71]  H. Whyte,et al.  Blood pressure monitoring in neonates: comparison of umbilical and peripheral artery catheter measurements. , 1984, The Journal of pediatrics.

[72]  Christian Ott,et al.  Comparison of Two Noninvasive Devices for Measurement of Central Systolic Blood Pressure With Invasive Measurement During Cardiac Catheterization , 2012, Journal of clinical hypertension.

[73]  Chulhong Min,et al.  eSense: Earable Platform for Human Sensing , 2018, MobiSys.

[74]  A. Manara,et al.  Organ donation and transplantation , 2019, Challenging Concepts in Critical Care.

[75]  Jiankun Liu,et al.  Model-based error analysis of the oscillometric fixed-ratio blood pressure measurement method , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[76]  D. Ubbink,et al.  Toe blood pressure measurements in patients suspected of leg ischaemia: a new laser Doppler device compared with photoplethysmography. , 2004, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[77]  G Parati,et al.  Blood pressure measuring devices: recommendations of the European Society of Hypertension , 2001, BMJ : British Medical Journal.

[78]  O Munck,et al.  Estimation of peripheral arteriosclerotic disease by ankle blood pressure measurements in a population study of 60-year-old men and women. , 1981, Journal of chronic diseases.

[79]  J. Mathis,et al.  Physical characteristics of balloon catheter systems used in temporary cerebral artery occlusion. , 1994, AJNR. American journal of neuroradiology.

[80]  Ramakrishna Mukkamala,et al.  Error Mechanisms of the Oscillometric Fixed-Ratio Blood Pressure Measurement Method , 2012, Annals of Biomedical Engineering.

[81]  C. Agyemang,et al.  Masked Hypertension: Evidence of the Need to Treat , 2010, Current hypertension reports.

[82]  T. Kurki,et al.  Noninvasive continuous blood pressure measurement from the finger: Optimal measurement conditions and factors affecting reliability , 2004, Journal of Clinical Monitoring.

[83]  T Kriesand,et al.  Home blood pressure monitoring. , 1996, American family physician.

[84]  I F Black,et al.  Application of Doppler ultrasound to blood pressure measurement in small infants. , 1972, The Journal of pediatrics.

[85]  John C.-I. Chuang,et al.  Classifying mental gestures with in-ear EEG , 2016, 2016 IEEE 13th International Conference on Wearable and Implantable Body Sensor Networks (BSN).

[86]  G. Fortino,et al.  PPG-based methods for non invasive and continuous blood pressure measurement: an overview and development issues in body sensor networks , 2010, 2010 IEEE International Workshop on Medical Measurements and Applications.