Circuit breaker operational health assessment via condition monitoring data

This paper presents a practical approach to evaluation of the operational health and reliability of circuit breakers in substations. Motivated by the recent failure surveys conducted by CIGRE working groups, circuit breaker condition data, obtained by monitoring critical parameters such as operational timings, tank gas pressure and temperature, mechanism traveling time and speed, etc., is used to evaluate the proposed health index. The proposed measure would help identify the transmission lines available for switching actions from the circuit breaker reliability view point. The proposed health index also provides a valuable input for substation maintenance personnel. The applicability of the proposed methodology is explored and validated using the actual circuit breaker condition data collected in the field.

[1]  M. Runde,et al.  Vibration Analysis for Diagnostic Testing of Circuit Breakers , 1996, IEEE Power Engineering Review.

[2]  Anton Janssen,et al.  International Surveys on Circuit-Breaker Reliability Data for Substation and System Studies , 2014, IEEE Transactions on Power Delivery.

[3]  Mladen Kezunovic,et al.  Reliable Implementation of Robust Adaptive Topology Control , 2014, 2014 47th Hawaii International Conference on System Sciences.

[4]  Yingzhong Gu,et al.  Fast Sensitivity Analysis Approach to Assessing Congestion Induced Wind Curtailment , 2015, IEEE Transactions on Power Systems.

[5]  J.R. McDonald,et al.  Providing Decision Support for the Condition-Based Maintenance of Circuit Breakers Through Data Mining of Trip Coil Current Signatures , 2007, IEEE Transactions on Power Delivery.

[6]  Mahmud Fotuhi-Firuzabad,et al.  Critical Component Identification in Reliability Centered Asset Management of Power Distribution Systems Via Fuzzy AHP , 2012, IEEE Systems Journal.

[7]  Mladen Kezunovic,et al.  Cost/benefit analysis for circuit breaker maintenance planning and scheduling , 2013, 2013 North American Power Symposium (NAPS).

[8]  R.P. O'Neill,et al.  Optimal Transmission Switching With Contingency Analysis , 2010, IEEE Transactions on Power Systems.

[9]  M. Runde,et al.  Continuous monitoring of circuit breakers using vibration analysis , 2005, IEEE Transactions on Power Delivery.

[10]  R. Billinton,et al.  A Comprehensive Scheme for Reliability Centered Maintenance in Power Distribution Systems—Part I: Methodology , 2013, IEEE Transactions on Power Delivery.

[11]  M. Runde Failure Frequencies for High-Voltage Circuit Breakers, Disconnectors, Earthing Switches, Instrument Transformers, and Gas-Insulated Switchgear , 2013, IEEE Transactions on Power Delivery.

[12]  Hiroshi Murase,et al.  Development of partial discharge monitoring technique using a neural network in a gas insulated substation , 1996, Proceedings of 1996 Transmission and Distribution Conference and Exposition.

[13]  Yingzhong Gu,et al.  Early Detection and Optimal Corrective Measures of Power System Insecurity in Enhanced Look-Ahead Dispatch , 2013, IEEE Transactions on Power Systems.

[14]  Mladen Kezunovic,et al.  Locating sub-cycle faults in distribution network applying half-cycle DFT method , 2014, 2014 IEEE PES T&D Conference and Exposition.

[15]  K. Frohlich,et al.  Model-aided diagnosis-a new method for online condition assessment of high voltage circuit breakers , 2000 .

[16]  M. Kezunovic,et al.  Automated Circuit Breaker Monitoring , 2007, 2007 IEEE Power Engineering Society General Meeting.

[17]  A. Mercier,et al.  A New Measurement Method of the Dynamic Contact Resistance of HV Circuit Breakers , 2006, 2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition.

[18]  Mladen Kezunovic,et al.  Assessing circuit breaker life cycle using condition-based data , 2013, 2013 IEEE Power & Energy Society General Meeting.

[19]  X. Xu,et al.  Improving circuit breaker maintenance management tasks by applying mobile agent software technology , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[20]  Mladen Kezunovic,et al.  THE USE OF BIG DATA FOR OUTAGE MANAGEMENT IN DISTRIBUTION SYSTEMS , 2014 .

[21]  Takaaki Sakakibara,et al.  Application of gas pressure sensor for fault location system in gas insulated substation , 1995 .

[22]  Jian-Da Wu,et al.  An expert system for fault diagnosis in internal combustion engines using wavelet packet transform and neural network , 2009, Expert Syst. Appl..

[23]  M. Kezunovic,et al.  Automated monitoring and analysis of circuit breaker operation , 2005, IEEE Transactions on Power Delivery.

[24]  Brian Lithgow,et al.  New Fault Diagnosis of Circuit Breakers , 2002, IEEE Power Engineering Review.

[25]  Zoran Stanisic Method for static and dynamic resistance measurements of HV circuit breaker , 2011, 2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies.

[26]  Hiroshi Murase,et al.  On-site measurement for the development of on-line partial discharge monitoring system in GIS , 1994 .

[27]  R. Billinton,et al.  A Comprehensive Scheme for Reliability-Centered Maintenance in Power Distribution Systems—Part II: Numerical Analysis , 2013, IEEE Transactions on Power Delivery.