A Fast Time-Domain Current Harmonic Extraction Algorithm for Power Quality Improvement Using Three-Phase Active Power Filter

Harmonic current estimation is the key aspect of Active Power Filter (APF) control algorithms to generate a reference current for harmonic compensation. This paper proposes a novel structure for harmonic current estimation scheme based on Trigonometric Orthogonal Principle (TOP) and Self Tuning Filter (STF). The key advantages of the proposed method are its simplicity, low computational burden and faster execution time in comparison to the conventional harmonic current estimation approaches. The TOP method provides a simple and fast approach to extract the reference current, while STF provides a simplified structure to generate the required synchronization signal that eliminates the need of a Phase Locked Loop (PLL) algorithm for synchronization. As a result, it exhibits less complexity in implementation and less consumption of microcontroller‘s resources; thus, the proposed method can be implemented using a low-cost microcontroller. It is shown in the paper that the proposed method provides 10 times gain in processing speed as compared to the conventional DQ method. The proposed approach is analyzed in detail, and its effectiveness and superior performance are verified using simulation and experimental results.

[1]  Swen Bosch,et al.  Predictive Current Control for an Active Power Filter With LCL-Filter , 2018, IEEE Transactions on Industrial Electronics.

[2]  Y. Li,et al.  Three-Phase Cascaded Delayed Signal Cancellation PLL for Fast Selective Harmonic Detection , 2013, IEEE Transactions on Industrial Electronics.

[3]  F. Blaabjerg,et al.  Detection is key - Harmonic detection methods for active power filter applications , 2007, IEEE Industry Applications Magazine.

[4]  Francisco A. S. Neves,et al.  Digital Filters for Fast Harmonic Sequence Component Separation of Unbalanced and Distorted Three-Phase Signals , 2012, IEEE Transactions on Industrial Electronics.

[5]  Fang Zhuo,et al.  A Single-phase Harmonics Extraction Algorithm Based on the Principle of Trigonometric Orthogonal Functions , 2017 .

[6]  Carlos Ariño,et al.  Optimization Algorithm for Selective Compensation in a Shunt Active Power Filter , 2015, IEEE Transactions on Industrial Electronics.

[7]  Salvador Pérez Litrán,et al.  Practical evaluation of unbalance and harmonic distortion in power conditioning , 2016 .

[8]  Fang Zhuo,et al.  An advanced harmonic extraction technique applied to a three-phase three-level active power filter , 2017, 2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017 - ECCE Asia).

[9]  Fang Zhuo,et al.  Design and implementation of a three-level active power filter for harmonic and reactive power compensation , 2018 .

[10]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[11]  V. Blasko,et al.  A Novel Method for Selective Harmonic Elimination in Power Electronic Equipment , 2007, IEEE Transactions on Power Electronics.

[12]  Marc Hiller,et al.  Grid-connected medium-voltage converters with parallel voltage-source active filters , 2019 .

[13]  Wajahat Ullah Khan Tareen,et al.  Three-Phase Transformerless Shunt Active Power Filter With Reduced Switch Count for Harmonic Compensation in Grid-Connected Applications , 2018, IEEE Transactions on Power Electronics.

[14]  Fang Zheng Peng,et al.  Reactive power and harmonic compensation based on the generalized instantaneous reactive power theory for three-phase power systems , 1996 .

[15]  H. Lin Intelligent Neural Network-Based Fast Power System Harmonic Detection , 2007, IEEE Transactions on Industrial Electronics.

[16]  Jinghong Guo,et al.  Power harmonic analysis based on Orthogonal Trigonometric Functions Family , 2010, CICED 2010 Proceedings.

[17]  Muhammad Kashif,et al.  Evaluation of Fundamental dq Synchronous Reference Frame Harmonic Detection Method for Single Phase Shunt Active Power Filter , 2014 .

[18]  M. Abdel-Salam,et al.  Active power filters for harmonic cancellation in conventional and advanced aircraft electric power systems , 2009 .

[19]  Xu Wang,et al.  Control Techniques for Active Power Filters , 2010, 2010 International Conference on Electrical and Control Engineering.

[20]  Weidong Xiao,et al.  Single phase NTD PLL for fast dynamic response and operational robustness under abnormal grid condition , 2020 .

[21]  J. Dixon,et al.  A three-phase active power filter operating with fixed switching frequency for reactive power and current harmonic compensation , 1992, Proceedings of the 1992 International Conference on Industrial Electronics, Control, Instrumentation, and Automation.

[22]  Alka Singh,et al.  Application of self tuning filter for power quality improvement in three-phase-three-wire distorted grid system , 2017, 2017 7th International Conference on Power Systems (ICPS).

[23]  Bidyadhar Subudhi,et al.  A New grid synchronisation scheme for a three-phase PV system using self-tuning filtering approach , 2017 .

[24]  Longfu Luo,et al.  Power Quality Management of PV Power Plant With Transformer Integrated Filtering Method , 2019, IEEE Transactions on Power Delivery.

[25]  S. R. Wagh,et al.  A Comparative Study on Compensating Current Generation Algorithms for Shunt Active Filter under Non-linear Load Conditions , 2013 .

[26]  Salah Saad,et al.  A comparative study of harmonic currents extraction by simulation and implementation , 2013 .

[27]  Patricio Salmerón,et al.  Instantaneous Reactive Power Theory Applied to Active Power Filter Compensation: Different Approaches, Assessment, and Experimental Results , 2008, IEEE Transactions on Industrial Electronics.

[28]  Haibing Hu,et al.  Fast and Flexible Selective Harmonic Extraction Methods Based on the Generalized Discrete Fourier Transform , 2018, IEEE Transactions on Power Electronics.

[29]  Longfu Luo,et al.  A Transformer Integrated Filtering System for Power Quality Improvement of Industrial DC Supply System , 2020, IEEE Transactions on Industrial Electronics.

[30]  Francisco A. S. Neves,et al.  A Space-Vector Discrete Fourier Transform for Unbalanced and Distorted Three-Phase Signals , 2010, IEEE Transactions on Industrial Electronics.

[31]  Hari Om Bansal,et al.  Hardware in the loop implementation of wavelet based strategy in shunt active power filter to mitigate power quality issues , 2019, Electric Power Systems Research.

[32]  Josep M. Guerrero,et al.  PLL With MAF-Based Prefiltering Stage: Small-Signal Modeling and Performance Enhancement , 2016, IEEE Transactions on Power Electronics.

[33]  Ahmet Teke,et al.  Artificial neural network-based discrete-fuzzy logic controlled active power filter , 2014 .

[34]  A. Khezzar,et al.  A novel strategy for shunt active filter control , 2015 .

[35]  Weidong Xiao,et al.  Fast identification of active and reactive current component for single phase grid interconnection , 2017, 2017 20th International Conference on Electrical Machines and Systems (ICEMS).