Frequency Disturbance Triggered D-Axis Current Injection Scheme for Islanding Detection

An islanding detection technique, based on monitoring of impedance based parameter at the terminal of distributed generators (DG) through the low frequency current injection is proposed in this paper. To reduce the power quality issues, current injection is initiated only during the grid disturbances. The disturbances are identified by comparing the frequency data of the DG bus with respect to reference substation bus. After the disturbance identification, a low frequency current is injected through the inverter d-axis current controller. An impedance based parameter is formulated to check the status of operation of microgrid. The islanding detection parameter is a function of Thevenins impedance seen at the inverter DG terminals. The main advantage of the proposed method is that, the power quality degradation associated with current injection methods is considerably minimized. Further, the considered islanding detection parameter is independent of the operating condition of inverter based DG. Various islanding and non-islanding cases are simulated to study the selectivity of the proposed technique. The simulation and control hardware in the loop test results show the effectiveness of the proposed technique in identifying islanding in less than 170ms.

[1]  Ilia Voloh,et al.  Islanding detection with Phasor Measurement Units , 2014, 2014 67th Annual Conference for Protective Relay Engineers.

[2]  Liuchen Chang,et al.  A Reference Impedance-Based Passive Islanding Detection Method for Inverter-Based Distributed Generation System , 2015, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[3]  Michael P. Andersen,et al.  Precision Micro-Synchrophasors for Distribution Systems: A Summary of Applications , 2017, IEEE Transactions on Smart Grid.

[4]  Suman Murugesan,et al.  Hybrid Analyzing Technique for Active Islanding Detection Based on d-Axis Current Injection , 2018, IEEE Systems Journal.

[5]  F. Blaabjerg,et al.  Control of Power Converters in AC Microgrids , 2012, IEEE Transactions on Power Electronics.

[6]  Y. Xue,et al.  Synchrophasor-Based Islanding Detection for Distributed Generation Systems Using Systematic Principal Component Analysis Approaches , 2015, IEEE Transactions on Power Delivery.

[7]  R. Iravani,et al.  Current injection for active islanding detection of electronically-interfaced distributed resources , 2006, IEEE Transactions on Power Delivery.

[8]  Dushan Boroyevich,et al.  A D-Q Frame Controller for a Full-Bridge Single Phase Inverter Used in Small Distributed Power Generation Systems , 2007, APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition.

[9]  Premalata Jena,et al.  Rate of change of superimposed negative sequence impedance based islanding detection technique for distributed generations , 2016 .

[10]  F. Blaabjerg,et al.  Online grid impedance measurement suitable for multiple PV inverters running in parallel , 2006, Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06..

[11]  Pankaj Gupta,et al.  Active ROCOF Relay for Islanding Detection , 2017, IEEE Transactions on Power Delivery.

[12]  H.H. Zeineldin,et al.  A $Q$– $f$ Droop Curve for Facilitating Islanding Detection of Inverter-Based Distributed Generation , 2009, IEEE Transactions on Power Electronics.

[13]  R. S. Bhatia,et al.  Average Absolute Frequency Deviation Value Based Active Islanding Detection Technique , 2015, IEEE Transactions on Smart Grid.

[14]  P. Garcia,et al.  Active Islanding Detection for Multiple Parallel-Connected Inverter-Based Distributed Generators Using High-Frequency Signal Injection , 2014, IEEE Transactions on Power Electronics.

[15]  Eduardo Galvan,et al.  New Low-Distortion $Q$–$f$ Droop Plus Correlation Anti-Islanding Detection Method for Power Converters in Distributed Generation Systems , 2015, IEEE Transactions on Industrial Electronics.

[16]  Liuchen Chang,et al.  Passive Islanding Detection Approach Based on Tracking the Frequency-Dependent Impedance Change , 2015, IEEE Transactions on Power Delivery.

[17]  S. R. Samantaray,et al.  Assessment of ROCPAD Relay for Islanding Detection in Distributed Generation , 2011, IEEE Transactions on Smart Grid.

[18]  Tianshu Bi,et al.  An Islanding Detection Method for Multi-DG Systems Based on High-Frequency Impedance Estimation , 2017, IEEE Transactions on Sustainable Energy.

[19]  Yong Liu,et al.  Wide-area measurement system development at the distribution level: An FNET/GridEye example , 2016, 2016 IEEE Power and Energy Society General Meeting (PESGM).

[20]  Roy Moxley,et al.  Interconnection control of distributed generation with time-synchronized phasors , 2011, 2011 IEEE/PES Power Systems Conference and Exposition.

[21]  Sami Repo,et al.  An Anti-Islanding Protection Method Based on Reactive Power Injection and ROCOF , 2017, IEEE Transactions on Power Delivery.

[22]  D. John Morrow,et al.  Loss-of-mains protection system by application of phasor measurement unit technology with experimentally assessed threshold settings , 2015 .

[23]  X. Liu,et al.  Principal Component Analysis of Wide-Area Phasor Measurements for Islanding Detection—A Geometric View , 2015, IEEE Transactions on Power Delivery.

[24]  Bin Wu,et al.  Improved Active Frequency Drift Anti-islanding Detection Method for Grid Connected Photovoltaic Systems , 2012, IEEE Transactions on Power Electronics.