Correlation of Doppler US tumor signals with neovascular morphologic features.

Abnormal Doppler ultrasound signals were detected in 44 of 47 patients with primary malignant tumors of the liver, kidney, adrenal gland, or pancreas (94%). Two different signal types were noted: a high-velocity signal (n = 38) with Doppler shifts exceeding 3 kHz (at an insonating frequency of 3 MHz) and a very low-impedance signal (n = 9) demonstrating little systolic-diastolic variation. In three patients, both types were present. In 19 patients, histologic (n = 12) and/or angiographic (n = 16) correlation was available. Among 13 patients with angiographic studies and signals over 3 kHz, arteriovenous shunting was demonstrated in six. The ratio of the systolic to diastolic Doppler shift is a function of vascular impedance. This systolic/diastolic index was less than 3 in eight patients with histologic correlation. All eight had prominent vascular spaces, and the flow in such thin-walled, endothelium-lined spaces would account for the low-impedance signals. Of nine patients with systolic/diastolic indexes of 3 or less and angiographic correlation, three had marked and four had moderate tumor staining.