Asymmetrical phase-shifted full-bridge

In comparison to forward-converters bridge topologies make use of parasitic components for resonant transition without need of additional clamping circuitry. Thus, they are privileged in building high frequency high power converters, even if high efficiency is required. This paper introduces a new modulation scheme for H-bridges, which combines PWM and phase-modulation. An analysis of the ideal circuit is presented together with design guidelines. Some experimental data for a converter prototype are given for 300 V/5 V-750 W, 250 kHz,.

[1]  Pierre Mathys,et al.  PSPICE simulations and 3D-PCB transformers for ZVS full bridge converters , 1993 .

[2]  N. Mohan,et al.  Asymmetrical duty cycle permits zero switching loss in PWM circuits with no conduction loss penalty , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[3]  I. Jitaru High frequency, soft transitions converter , 1993, Proceedings Eighth Annual Applied Power Electronics Conference and Exposition,.

[4]  A. Fiedler,et al.  Investigation of asymmetrical phase-shifted full bridge [power convertors] , 1995, Proceedings of IECON '95 - 21st Annual Conference on IEEE Industrial Electronics.

[5]  J. Sebastian,et al.  Optimized synchronous rectification stage for low output voltage (3.3 V) DC/DC conversion , 1994, Proceedings of 1994 Power Electronics Specialist Conference - PESC'94.