Clinical application of multi-contrast 7-T MR imaging in multiple sclerosis: increased lesion detection compared to 3 T confined to grey matter

AbstractObjectivesSeven-Tesla MRI demonstrated new pathological features of multiple sclerosis (MS) using T2*-weighted sequences. However, a clinical MRI protocol at 7 T has never been investigated. We evaluated the clinical value of 7-T MRI by investigating the sensitivity of lesion detection compared with 3 T.MethodsThirty-eight MS patients and eight healthy controls underwent multi-contrast MRI using 3D T1-weighted (3D-T1w), 2D dual-echo T2-weighted (2D-T2w) and 3D fluid-attenuated inversion recovery (3D-FLAIR) at 3 and 7 T. Images were analysed for focal lesions, which were counted and categorised according to anatomical location. The study was approved by the institutional review board.ResultsLesion-wise analysis showed increased lesion counts in cortical grey matter (GM) at 7 T of 91, 75 and 238 % for 3D-T1w, 2D-T2w and FLAIR sequences, respectively. Patient-wise analysis confirmed this for 2D-T2w and FLAIR (P < 0.023 and P < 0.001). Seven-Tesla white matter (WM) lesion detection was not increased; 3D-FLAIR even detected significantly more WM lesions at 3 T.ConclusionsUsing a clinical multi-contrast MRI protocol, increased lesion detection was observed in cortical GM but not in WM. Given the clinical relevance of GM abnormalities, this may have consequences for clinical outcome measures, prognostic classification and future diagnostic criteria incorporating GM abnormalities.Key Points• Standard multi-contrast 7-T magnetic resonance imaging in multiple sclerosis is feasible. • Seven-Tesla MRI detects more cortical grey matter lesions than 3 T. • Seven-Tesla MRI fares no better than 3 T in detecting white matter lesions. • Grey matter abnormalities have high diagnostic and prognostic relevance in MS.

[1]  Jullie W Pan,et al.  DEMONSTRATING THE PERIVASCULAR DISTRIBUTION OF MS LESIONS IN VIVO WITH 7-TESLA MRI , 2008, Neurology.

[2]  Nikos Evangelou,et al.  A Comparison of 3T and 7T in the Detection of Small Parenchymal Veins Within MS Lesions , 2009, Investigative radiology.

[3]  M. Schlamann,et al.  First Clinical Study on Ultra-High-Field MR Imaging in Patients with Multiple Sclerosis: Comparison of 1.5T and 7T , 2009, American Journal of Neuroradiology.

[4]  T. Benner,et al.  Focal cortical lesion detection in multiple sclerosis: 3 tesla DIR versus 7 tesla FLASH‐T2* , 2012, Journal of magnetic resonance imaging : JMRI.

[5]  David Pitt,et al.  Imaging cortical lesions in multiple sclerosis with ultra-high-field magnetic resonance imaging. , 2010, Archives of neurology.

[6]  Jeffrey A. Cohen,et al.  Diagnostic criteria for multiple sclerosis: 2010 Revisions to the McDonald criteria , 2011, Annals of neurology.

[7]  Rohit Bakshi,et al.  MRI in multiple sclerosis: current status and future prospects , 2008, The Lancet Neurology.

[8]  Mike P. Wattjes,et al.  Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR , 2011, European Radiology.

[9]  J. Kurtzke Rating neurologic impairment in multiple sclerosis , 1983, Neurology.

[10]  A. Compston,et al.  Recommended diagnostic criteria for multiple sclerosis: Guidelines from the international panel on the diagnosis of multiple sclerosis , 2001, Annals of neurology.

[11]  C. Poser,et al.  Diagnostic criteria for multiple sclerosis , 2001, Clinical Neurology and Neurosurgery.

[12]  Pratik Mukherjee,et al.  High‐Resolution Phased‐Array MRI of the Human Brain at 7 Tesla: Initial Experience in Multiple Sclerosis Patients , 2010, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[13]  Caterina Mainero,et al.  In vivo imaging of cortical pathology in multiple sclerosis using ultra-high field MRI , 2009, Neurology.

[14]  F. Barkhof,et al.  Accumulation of cortical lesions in MS: relation with cognitive impairment , 2009, Multiple sclerosis.

[15]  Massimo Filippi,et al.  7. Mri Assessment of Iron Deposition in Multiple Sclerosis , 2022 .

[16]  F. Barkhof,et al.  MRI criteria for MS in patients with clinically isolated syndromes , 2010, Neurology.

[17]  M. Calabrese,et al.  Magnetic resonance evidence of cortical onset of multiple sclerosis , 2009, Multiple sclerosis.

[18]  Robert Zivadinov,et al.  Signal abnormalities on 1.5 and 3 Tesla brain MRI in multiple sclerosis patients and healthy controls. A morphological and spatial quantitative comparison study , 2009, NeuroImage.

[19]  Frederik Barkhof,et al.  Intracortical lesions in multiple sclerosis: improved detection with 3D double inversion-recovery MR imaging. , 2005, Radiology.

[20]  Hellmut Merkle,et al.  Chronic multiple sclerosis lesions: characterization with high-field-strength MR imaging. , 2012, Radiology.

[21]  A. S. Hall,et al.  NUCLEAR MAGNETIC RESONANCE IMAGING OF THE BRAIN IN MULTIPLE SCLEROSIS , 1981, The Lancet.

[22]  Yulin Ge,et al.  Seven-Tesla magnetic resonance imaging: new vision of microvascular abnormalities in multiple sclerosis. , 2008, Archives of neurology.

[23]  S. Nelson,et al.  Quantitative in vivo magnetic resonance imaging of multiple sclerosis at 7 Tesla with sensitivity to iron , 2008, Annals of neurology.

[24]  Nikos Evangelou,et al.  3 Tesla and 7 Tesla MRI of multiple sclerosis cortical lesions , 2010, Journal of magnetic resonance imaging : JMRI.

[25]  Robert A. Gross,et al.  Consensus recommendations for MS cortical lesion scoring using double inversion recovery MRI , 2011 .

[26]  Massimo Filippi,et al.  Cortical lesions and atrophy associated with cognitive impairment in relapsing-remitting multiple sclerosis. , 2009, Archives of neurology.

[27]  F. Barkhof,et al.  Does high field MRI allow an earlier diagnosis of multiple sclerosis? , 2008, Journal of Neurology.

[28]  M. Filippi,et al.  Intracortical lesions , 2010, Neurology.

[29]  F. Barkhof,et al.  Improved in vivo detection of cortical lesions in multiple sclerosis using double inversion recovery MR imaging at 3 Tesla , 2010, European Radiology.

[30]  J A Frank,et al.  Standardized MR imaging protocol for multiple sclerosis: Consortium of MS Centers consensus guidelines. , 2006, AJNR. American journal of neuroradiology.

[31]  F. Barkhof,et al.  2010 revisions to mcDonald criteria for diagnosis of multiple sclerosis: Impact of 3‐tesla magnetic resonance imaging , 2011, Annals of neurology.

[32]  F. Barkhof,et al.  Inflammation high-field magnetic resonance imaging. , 2012, Neuroimaging clinics of North America.

[33]  W. L. Benedict,et al.  Multiple Sclerosis , 2007, Journal - Michigan State Medical Society.

[34]  F. Barkhof,et al.  High field MRI in the diagnosis of multiple sclerosis: high field–high yield? , 2009, Neuroradiology.

[35]  M. Filippi,et al.  A 3‐year magnetic resonance imaging study of cortical lesions in relapse‐onset multiple sclerosis , 2009, Annals of neurology.

[36]  M. Filippi,et al.  Cortical lesions in primary progressive multiple sclerosis , 2009, Neurology.

[37]  C. Polman,et al.  Infratentorial lesions predict long-term disability in patients with initial findings suggestive of multiple sclerosis. , 2004, Archives of neurology.

[38]  B. Scheithauer,et al.  Inflammatory cortical demyelination in early multiple sclerosis. , 2011, The New England journal of medicine.

[39]  Peter R Luijten,et al.  High‐resolution magnetization‐prepared 3D‐FLAIR imaging at 7.0 Tesla , 2010, Magnetic resonance in medicine.

[40]  S. Reingold,et al.  Diagnostic criteria for multiple sclerosis: 2005 revisions to the “McDonald Criteria” , 2005, Annals of neurology.

[41]  Mike P. Wattjes,et al.  Higher sensitivity in the detection of inflammatory brain lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis using high field MRI: an intraindividual comparison of 1.5 T with 3.0 T , 2006, European Radiology.