Electrochemical Analysis of Some Toxic Metals by Ion–Selective Electrodes
暂无分享,去创建一个
Shilpi Agarwal | M. Ganjali | H. Khani | Vinod K. Gupta | P. Norouzi | S. Agarwal | A. Nayak | M. R. Ganjali | P. Norouzi | H. Khani | Arunima Nayak | V. Gupta | Hadi Khani
[1] M. Ganjali,et al. Carcinoembryonic antigen admittance biosensor based on Au and ZnO nanoparticles using FFT admittance voltammetry. , 2011, Analytical chemistry.
[2] M. Shahlaei,et al. New Zn(II)-Selective Potentiometric Sensor Based on 3-Hydroxy-2-Naphthoic Hydrazide , 2009 .
[3] A. Mittal,et al. Removal and Recovery of the Hazardous Azo Dye Acid Orange 7 through Adsorption over Waste Materials: Bottom Ash and De-Oiled Soya , 2006 .
[4] M. Arvand,et al. New Fe(II) Ion-selective electrode based On N-Phenylaza-15-Crown-5 as neutral carrier in PVC matrix , 2009 .
[5] M. Aghaie,et al. Silver(I)-selective membrane potentiometric sensor based on two recently synthesized ionophores containing calix[4]arene , 2009 .
[6] M. Ganjali,et al. Novel Potentiometric Membrane Sensor for the Determination of Trace Amounts of Chromium(III) Ions , 2003, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[7] M. Naushad. A new ion-selective electrode based on aluminium tungstate for Fe(III) determination in rock sample, pharmaceutical sample and water sample , 2008 .
[8] Ashutosh Kumar Singh,et al. Polymeric membrane and coated graphite electrode based on newly synthesized tetraazamacrocyclic ligand for trace level determination of nickel ion in fruit juices and wine samples , 2009 .
[9] M. Ganjali,et al. Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) Sensor , 2007 .
[10] R. Goyal,et al. Nickel(II)-selective sensor based on dibenzo-18-crown-6 in PVC matrix. , 2007, Talanta.
[11] Y. Shim,et al. Chromium(III)-selective Electrode Using p-(4-Acetanilidazo)calix[4]arene as an Ionophore in PVC Matrix , 2008 .
[12] M. H. Mashhadizadeh,et al. Nickel(II) selective membrane potentiometric sensor using a recently synthesized mercapto compound as neutral carrier. , 2003, Talanta.
[13] M. Shamsipur,et al. Lead ion-selective membrane electrode based on 1,10-dibenzyl-1,10-diaza-18-crown-6 , 2000 .
[14] Ashutosh Kumar Singh,et al. A New PVC-Membrane Electrode Based on a Diazatetrathia (N2S4) Macrocyclic Ligand for Selective Determination of Silver Ion , 2003 .
[15] A. Mittal,et al. Adsorption of Safranin-T from wastewater using waste materials- activated carbon and activated rice husks. , 2006, Journal of colloid and interface science.
[16] Y. Shim,et al. A novel cobalt(II)-selective potentiometric sensor based on p-(4-n-butylphenylazo)calix[4]arene. , 2009, Talanta.
[17] R. Goyal,et al. A new Zn(II)-selective potentiometric sensor based on 4-tert-butylcalix[4]arene in PVC matrix. , 2006, Talanta.
[18] Ashutosh Kumar Singh,et al. Development of an electrochemical sensor based on Schiff base for Cu(II) determination at nano level in river water and edible materials , 2009 .
[19] Yong-Kook Choi,et al. Lead(II)-selective electrodes based on tetrakis(2-hydroxy-1-naphthyl)porphyrins: the effect of atropisomers , 2004 .
[20] Ashutosh Kumar Singh,et al. Comparative evaluation of Dy(III) selective poly(vinyl) chloride based membrane electrodes of macrocyclic tetraimine Schiff's bases. , 2009, Talanta.
[21] L. Singh,et al. PVC-BASED NEUTRAL CARRIER AND ORGANIC EXCHANGER MEMBRANES AS SENSORS FOR THE DETERMINATION OF BA2+ AND SR2+ , 1999 .
[22] Ajay K. Jain,et al. Macrocycle Based Membrane Sensors for the Determination of Cobalt(II) Ions , 1997 .
[23] Rainer Ludwig,et al. Electroanalytical studies on cadmium(II) selective potentiometric sensors based on t-butyl thiacalix[4]arene and thiacalix[4]arene in poly(vinyl chloride) , 2008 .
[24] A. Bharti,et al. A comparative study on PVC based sensors in determination of. , 2011, Analytical methods : advancing methods and applications.
[25] M. Shamsipur,et al. Novel Ag+ ion-selective electrodes based on two new mixed azathioether crowns containing a 1,10-phenanthroline sub-unit , 2002 .
[26] A. Amr,et al. New lead (II) selective membrane potentiometric sensors based on chiral 2,6-bis-pyridinecarboximide derivatives. , 2003, Talanta.
[27] M. Lai,et al. Mercury(II) and silver(I) ion-selective electrodes based on dithia crown ethers , 1986 .
[28] V. Gupta,et al. Novel PVC-based membrane sensors selective for vanadyl ions. , 1998, Talanta.
[29] I. Ion,et al. Polyvinyl chloride-based membranes of 3,7,11-tris (2-pyridylmethyl)-3,7,11,17-tetraazabicyclo [11.3.1] heptadeca-1(17),13,15-triene as a Pb(II)-selective sensor. , 2010 .
[30] M. Pal,et al. Comparative study on 2-amino-1,4-naphthoquinone derived ligands as indium (III) selective PVC-based sensors. , 2010, Talanta.
[31] S. Chandra,et al. A highly selective mercury electrode based on a diamine donor ligand. , 2005, Talanta.
[32] V. Gupta,et al. A polystyrene based heterogeneous solid membrane of cerium(IV) selenite as sensor for Hg(II) ions , 1995 .
[33] Ashutosh Kumar Singh,et al. Silver(I)-selective electrode based on [Bz2Oxo4(18)dieneS4] tetrathia macrocyclic carrier , 2006, Analytical and bioanalytical chemistry.
[34] R. Sharma,et al. Comparative studies on Tb (III)-selective PVC membrane sensors. , 2010, Talanta.
[35] Pankaj Kumar,et al. Cadmium(II)-selective sensors based on dibenzo-24-crown-8 in PVC matrix , 1999 .
[36] M. Ganjali,et al. Highly Selective and Sensitive Copper(II) Membrane Sensors Based on 6‐Methyl‐4‐(1‐phenylmethylidene)amino‐3‐thioxo‐1,2,4‐triazin‐5‐one as a New Neutral Ionophore , 2005 .
[37] A. Khan,et al. Analysis of mercury ions in effluents using potentiometric sensor based on nanocomposite cation exchanger Polyaniline–zirconium titanium phosphate , 2011 .
[38] C. Wardak,et al. Properties of the ion-selective electrode with a chelating pseudo-liquid membrane phase for zinc determination , 2000 .
[39] Synthesis of a new oxime and its application to the construction of a highly selective and sensitive Co(II) PVC-based membrane sensor. , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[40] V. Gupta,et al. Chelating ionophore based membrane sensors for copper(II) ions. , 2005, Talanta.
[41] A. Yari,et al. An electrochemical Ni(II)-selective sensor-based on a newly synthesized dioxime derivative as a neutral ionophore , 2006 .
[42] Ashutosh Kumar Singh,et al. Copper Incorporated [Me2(15)dieneN4] Macrocyclic Complex for Fabrication of PVC based Membrane Electrode for Copper , 2006 .
[43] D. Reinhoudt,et al. Silver selective electrodes based on thioether functionalized calix[4]arenes as ionophores , 1994 .
[44] V. Gupta,et al. Pb(II) Selective Potentiometric Sensor Based on 4‐tert‐Butylcalix[4]arene in PVC Matrix , 2002 .
[45] J. M. Bhatnagar,et al. Copper(II) selective electrochemical sensor based on Schiff Base complexes. , 2004, Talanta.
[46] A D Russell,et al. Antimicrobial activity and action of silver. , 1994, Progress in medicinal chemistry.
[47] M. Shamsipur,et al. Lead-selective poly(vinyl cholride) membrane electrode based on piroxicam as a neutral carrier , 2002 .
[48] M. Ghaedi,et al. Preparation of a new chromium(III) selective electrode based on 1-[(2-hydroxy ethyl) amino]-4-methyl-9H-thioxanthen-9-one as a neutral carrier. , 2010, Journal of hazardous materials.
[49] M. Ganjali,et al. Determination of Cr3+ ions in biological and environmental samples by a chromium(III) membrane sensor based on 5-amino-1-phenyl-1H-pyrazole-4-carboxamide , 2009 .
[50] H. Mukai,et al. Copper(II)-selective membrane electrode based on hydrotris(3-isopropylpyrazolyl)methane in a poly(vinyl chloride) matrix , 2003 .
[51] V. Gupta,et al. Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophores. , 2007, Analytica chimica acta.
[52] Ashutosh Kumar Singh,et al. Ni(II) selective sensors based on Schiff bases membranes in poly(vinyl chloride). , 2008, Analytica chimica acta.
[53] E. Pretsch,et al. Potentiometric Cd2+-selective electrode with a detection limit in the low ppt range , 2001 .
[54] R. Razavi,et al. Cobalt(II)-selective membrane electrode using a recently synthesized mercapto compound , 2002 .
[55] Ashutosh Kumar Singh,et al. Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II). , 2007, Analytica chimica acta.
[56] M. Ganjali,et al. Highly selective and sensitive chromium(III) membrane sensors based on a new tridentate Schiff's base , 2006 .
[57] S. Alegret,et al. Lead(II) ion selective electrodes with PVC membranes based on two bis-thioureas as ionophores: 1,3-bis(N'-benzoylthioureido)benzene and 1,3-bis(N'-furoylthioureido)benzene. , 2010, Journal of hazardous materials.
[58] Shiva Agarwal,et al. A Porphyrin Based Potentiometric Sensor for Zn2+ Determination , 2003 .
[59] M. Rahimi‐Nasrabadi,et al. Highly selective and sensitive copper membrane electrode based on a new synthesized Schiff base. , 2007, Talanta.
[60] S. Ikram,et al. A polyvinylchloride-based cadmium ion-selective electrode using [Mo₂(OAc)₂(H₂-calix[4]arene)] as an electroactive material. , 2010, Water science and technology : a journal of the International Association on Water Pollution Research.
[61] Ali Akbar Saboury,et al. Highly Selective and Sensitive Membrane Sensors for Copper(II) Ion Based on a New Benzo‐Substituted Macrocyclic Diamide 6,7,8,9,10‐Hexahydro‐2H‐1,13,4,7,10‐benzodioxatriazacyclopentadecine‐3,11(4H,12H)‐dione , 2007 .
[62] H. Sharghi,et al. Novel PVC-membrane potentiometric sensors based on a recently synthesized sulfur-containing macrocyclic diamide for Cd2+ ion. Application to flow-injection potentiometry. , 2009, Journal of hazardous materials.
[63] A. Srivastava,et al. Coated wire lead(II) selective potentiometric sensor based on 4-tert-butylcalix[6]arene , 2004 .
[64] A. Kamel. A Novel Flow‐Through Planar Solid Contact Sensor for the Determination of Lead with Potentiometric Anionic Response , 2007 .
[65] M. Shamsipur,et al. Novel coated-graphite membrane sensor based on N,N′-dimethylcyanodiaza-18-crown-6 for the determination of ultra-trace amounts of lead , 2002 .
[66] A. Jain,et al. Anion recognition using newly synthesized hydrogen bonding diamide receptors: PVC based sensors for carbonate , 2006 .
[67] S. Srivastava,et al. PVC-Based 2,2,2-Cryptand Sensor for Zinc Ions. , 1996, Analytical chemistry.
[68] R. Goyal,et al. Aluminium (III)-selective PVC membrane sensor based on a Schiff base complex of N,N'-bis (salicylidene)-1,2-cyclohexanediamine , 2009 .
[69] Vinay Gupta,et al. A new membrane sensor for UO 22+ ions based on 2‐hydroxyacetophenoneoxime‐thiourea‐trioxane resin , 1997 .
[70] Vinod K. Gupta,et al. Comparative studies of neodymium (III)-selective PVC membrane sensors. , 2009, Analytica chimica acta.
[71] R. Mahajan,et al. Mercury(II) Ion-Selective Electrodes Based on p-tert-Butyl Calix[4]crowns with Imine Units , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[72] V. Jovanović,et al. A Copper(II) Ion-Selective Potentiometric Sensor Based on N,N′,N″,N′′′-Tetrakis(2-pyridylmethyl)-1,4,8,11-tetraazacyclotetradecane in PVC Matrix , 2010 .
[73] Ashutosh Kumar Singh,et al. A cobalt(II)-selective PVC membrane based on a Schiff base complex of N,N′-bis(salicylidene)-3,4-diaminotoluene , 2006 .
[74] G. Somer,et al. A novel iron(III) selective membrane electrode based on benzo-18-crown-6 crown ether and its applications , 2007 .
[75] M. Ganjali,et al. Fabrication of an iron(III) PVC-membrane sensor based on bis-benzilthiocarbohydrazide as a selective sensing material , 2009 .
[76] M. H. Mashhadizadeh,et al. Co2+-selective membrane electrode based on the Schiff Base NADS , 2003, Analytical and bioanalytical chemistry.
[77] F. Teixidor,et al. Silver-selective membrane electrodes using acyclic dithia benzene derivative neutral carriers. Comparison with related macrocyclic compounds , 1994 .
[78] V. Gupta,et al. Dicyclohexano-18-Crown-6 as Active Material in PVC Matrix Membrane for the Fabrication of Cadmium Selective Potentiometric Sensor (Proceedings of The 5Th East Asian Conference on Chemical Sensors: The 33RD Chemical Sensor Symposium) , 2001 .
[79] Suresh S. Jain,et al. Determination of lead using a poly(vinyl chloride)-based crown ether membrane , 1995 .
[80] M. J. Gismera,et al. Copper(II) Ion-Selective Electrodes Based on Dithiosalicylic and Thiosalicylic Acids , 2003 .
[81] A. Jain,et al. An iron(III) ion-selective sensor based on a mu-bis(tridentate) ligand. , 2007, Talanta.
[82] V. Gupta,et al. Anion recognition through novel C-thiophenecalix[4]resorcinarene: PVC based sensor for chromate ions. , 2005, Talanta.
[83] Ashutosh Kumar Singh,et al. Comparative study of Ag(I) selective poly(vinyl chloride) membrane sensors based on newly developed Schiff-base lariat ethers derived from 4,13-diaza-18-crown-6. , 2009, Analytica chimica acta.
[84] M. Ganjali,et al. Fabrication of an iron(III)-selective PVC membrane sensor based on a bis-bidentate Schiff base ionophore , 2008 .
[85] M. Hassouna,et al. N,N′-Bis(3-methyl-1-phenyl-4-benzylidine-5-pyrazolone)propylenediamine Schiff base as a neutral carrier for silver (I) ion-selective electrodes , 2010 .
[86] Heinrich Lang,et al. Copper(II)-selective potentiometric sensors based on porphyrins in PVC matrix , 2006 .
[87] K. G. Kumar,et al. A PVC plasticized sensor for Ni(II) ion based on a simple ethylenediamine derivative. , 2006, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[88] M. B. Saleh,et al. Novel mercury (II) ion-selective polymeric membrane sensor based on ethyl-2-benzoyl-2-phenylcarbamoyl acetate. , 2000, Talanta.
[89] A. Townshend. Metals and their Compounds in the Environment. Occurrence, Analysis and Biological Relevance , 1993 .
[90] S. Agarwal,et al. Chromium(III)-selective sensor based on tri-o-thymotide in PVC matrix , 2006 .
[91] R. Mahajan,et al. A mercury(II) ion-selective electrode based on neutral salicylaldehyde thiosemicarbazone. , 2003, Talanta.
[92] A. Abbaspour,et al. Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene. , 2001, Talanta.
[93] M. Gholivand,et al. Chromium(III) Ion Selective Electrode Based on Oxalic Acid Bis(Cyclohexylidene Hydrazide) , 2004 .
[94] M. Ganjali,et al. A novel iron (III)-PVC membrane potentiomeric sensor based on N-(2-hydroxyethyl)ethylenediamine-N,N',N"-triacetic acid , 2008 .
[95] Archana Singh,et al. Drug selective poly(vinyl chloride)-based sensor of desipramine hydrochloride , 2010 .
[96] Ashutosh Kumar Singh,et al. Comparative Studies of Tridentate Sulfur and Nitrogen‐Containing Ligands as Ionophores for Construction of Cadmium Ion‐Selective Membrane Sensors , 2007 .
[97] H. Sharghi,et al. Lead ion-selective membrane electrodes based on some recently synthesized 9,10-anthraquinone derivatives , 1998 .
[98] Suresh S. Jain,et al. A PVC‐based benzo‐15‐crown‐5 membrane sensor for cadmium , 1996 .
[99] M. H. Mashhadizadeh,et al. Asymmetrical Schiff Bases as Carriers in PVC Membrane Electrodes for Cadmium (II) Ions , 2005 .
[100] A. Srivastava,et al. Coated-wire iron(III) ion-selective electrode based on iron complex of 1,4,8,11-tetraazacyclotetradecane , 2005 .
[101] Polymeric Membrane Silver-ion Selective Electrodes Based on Schiff Base N,N'-Bis(pyridin-2-ylmethylene)benzene-1,2-diamine , 2010 .
[102] M. Ganjali,et al. Determination of Hg(II) ions in water samples by a novel Hg(II) sensor, based on calix[4]arene derivative , 2009 .
[103] L. Singh,et al. Copper(II)-selective electrodes based on macrocyclic compounds , 1995 .
[104] K. Gupta,et al. Effect of concentration of ion exchanger, plasticizer and molecular weight of cyanocopolymers on selectivity and sensitivity of Cu(II) ion selective electrodes , 2001 .
[105] K. Gupta,et al. Cadmium Ion‐Selective Electrode Based on Cyanocopolymer , 2000 .
[106] A. Kamel,et al. Response Characteristics of Copper‐Selective Polymer Membrane Electrodes Based on a Newly Synthesized Macrocyclic Calix[4]arene Derivative as a Neutral Carrier Ionophore , 2010 .
[107] A. Allafchian,et al. Highly Selective Potentiometric Membrane Sensor for Hg(II) Based on Bis(Benzoyl Acetone) Diethylene Triamine , 2008, IEEE Sensors Journal.
[108] M. B. Saleh. Iron(III) ionophores based on formylsalicylic acid derivatives as sensors for ion-selective electrodes , 2000 .
[109] L. Singh,et al. A new cerium(IV) vanadate‐based solid membrane electrode for bismuth(III) , 1997 .
[110] V. Gupta,et al. A New Zn2+-Selective Sensor Based on 5,10,15,20-Tetraphenyl-21H,23H-porphine in PVC Matrix , 2001 .
[111] M. Ganjali,et al. Cr(III) Ion-Selective Membrane Sensor Based on 1,3-Diamino-2-Hydroxypropane-N,N,N′,N′ Tetraacetic Acid , 2007 .
[112] Archana Singh,et al. A novel potentiometric membrane sensor for determination of Co2+ based on 5-amino-3-methylisothiazole , 2007 .
[113] L. Singh,et al. Neutral carrier and organic resin based membranes as sensors for uranyl ions , 1995 .
[114] Pankaj Kumar,et al. Determination of Uranyl Ions Using Poly(vinyl chloride) Based 4-tert-Butylcalix[6]arene Membrane Sensor , 1999 .
[115] M. Barzegar,et al. A PVC-based capric acid membrane potentiometric sensor for lead(II) ions , 2001 .
[116] M. Ganjali,et al. Construction of Nickel (II) PVC Membrane Electrochemical Sensor Based on 5-Methoxy-5,6-Diphenyl-4,5 Dihydro-3(2H)-Pyridazinethione as a Novel Ionophore , 2008 .
[117] Ayusman Sen,et al. Novel process of incorporating silver biocides into polymers , 2008 .
[118] C. Wardak. A highly selective lead-sensitive electrode with solid contact based on ionic liquid. , 2011, Journal of hazardous materials.
[119] R. Prasad,et al. Metallo-tetraazaporphyrin based anion sensors: regulation of sensor characteristics through central metal ion coordination , 2004 .
[120] M. H. Mashhadizadeh,et al. A novel ion selective membrane potentiometric sensor for direct determination of Fe(III) in the presence of Fe(II). , 2004, Talanta.
[121] R. Prasad,et al. Dibenzocyclamnickel(II) as Ionophore in PVC-Matrix for Ni2+-Selective Sensor , 2002 .
[122] Shiva Agarwal,et al. A zinc-selective electrode based on N,N′-bis(acetylacetone)ethylenediimine , 2006 .
[123] R. Goyal,et al. Comparative studies of ONNO-based ligands as ionophores for palladium ion-selective membrane sensors. , 2009, Talanta.
[124] V. Gupta,et al. PVC based 5,10,15,20-tetrakis (4-methoxyphenyl) porphyrinatocobalt(II) membrane potentiometric sensor for arsenite. , 2005, Talanta.
[125] S. Chung,et al. Silver(I)-selective membrane electrodes based on sulfur-containing podands. , 1997, Talanta.
[126] C. Wardak. Cobalt(II) ion-selective electrode with solid contact , 2008 .
[127] Anil K. Jain,et al. Ni(II)-selective ion sensors of salen type Schiff base chelates , 2005 .
[128] E. Foulkes. Biological Effects of Heavy Metals , 1989 .
[129] H. Fong,et al. Rechargeable Antibacterial and Antifungal Polymeric Silver Sulfadiazines , 2009 .
[130] A. Bharti,et al. A novel ion selective sensor for promethium determination. , 2010, Analytica chimica acta.
[131] W. Mahmoud,et al. Iron ion-selective electrodes for direct potentiometry and potentiotitrimetry in pharmaceuticals , 2001 .
[132] J. Jones,et al. The handbook of trace elements , 1997 .
[133] Ajay K. Jain,et al. Porphyrins as carrier in PVC based membrane potentiometric sensors for nickel(II) , 1997 .
[134] M. Shamsipur,et al. Novel fluorimetric bulk optode membrane based on 5,8-bis((5'-chloro-8'-hydroxy-7'-quinolinyl)methyl)-2,11-dithia-5,8-diaza-2,6-pyridinophane for selective detection of lead(II) ions. , 2010, Talanta.
[135] Vinod K. Gupta,et al. Removal of endosulfan and methoxychlor from water on carbon slurry. , 2008, Environmental science & technology.
[136] R. Goyal,et al. Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff's bases. , 2009, Analytica chimica acta.
[137] Xiwen He,et al. A lead ion-selective electrode based on a calixarene carboxyphenyl azo derivative , 2002 .
[138] P. Bühlmann,et al. Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors. , 1998, Chemical reviews.
[139] H. Sharghi,et al. Cobalt(II)-selective membrane electrode based on a recently synthesized benzo-substituted macrocyclic diamide. , 2001, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[140] A. Shockravi,et al. Fabrication of a novel iron(III)-PVC membrane sensor based on a new 1,1'-(iminobis(methan-1-yl-1-ylidene))dinaphthalen-2-ol synthetic ionophore for direct and indirect determination of free iron species in some biological and non-biological samples. , 2010, Journal of hazardous materials.
[141] Pankaj Kumar,et al. New nickel(II) selective potentiometric sensor based on 5,7,12,14-tetramethyldibenzotetraazaannulene in a poly(vinyl chloride) matrix , 2000 .
[142] Zhenning Yan,et al. Silver ion-selective electrodes based on bis(dialkyldithiocarbamates) as neutral ionophores , 2007 .
[143] Ashutosh Kumar Singh,et al. Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes. , 2007, Analytica chimica acta.
[144] Ashutosh Kumar Singh,et al. Tripodal chelating ligand-based sensor for selective determination of Zn(II) in biological and environmental samples , 2007, Analytical and bioanalytical chemistry.
[145] S. Mittal,et al. Potentiometric performance of 2-aminothiophenol based dipodal ionophore as a silver sensing material , 2007 .
[146] M. Salavati‐Niasari,et al. Copper Selective Electrode Based on 1,8-bis(2-Hydroxynap hthaldiminato)3,6-Dioxaoctane , 2006 .
[147] M. P. Mahajan,et al. 2,6-bis-methylsulfanyl-[1,3,5]thiadiazine-4-thione as a Ag+-selective ionophore. , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[148] Cobalt(II)-selective membrane sensor based on a [Me2(13)dieneN4] macrocyclic cobalt complex , 2006, Analytical and bioanalytical chemistry.
[149] I. Mohammadpoor‐Baltork,et al. Mercury selective membrane electrodes using 2-mercaptobenzimidazole, 2-mercaptobenzothiazole, and hexathiacyclooctadecane carriers , 2000 .
[150] K. Girish Kumar,et al. A PVC plasticized membrane sensor for nickel ions , 2006 .
[151] Xiwen He,et al. A mercury ion-selective electrode based on a calixarene derivative containing the thiazole azo group , 2003 .
[152] Suresh S. Jain,et al. Caesium PVC–crown (dibenzo-24-crown-8) based membrane sensor , 1995 .
[153] Pankaj Kumar,et al. PVC-based membranes of N,N' -dibenzyl -1,4,10,13 -tetraoxa -7,16 -diazacyclooctadecane as Pb(II)-selective sensor , 2006 .
[154] A. Jain,et al. A SOLID MEMBRANE SENSOR FOR HG2+ IONS , 1996 .
[155] H. Sharghi,et al. Highly Selective Chromium(III) PVC-Membrane Electrodes Based on Some Recently Synthesized Schiff's Bases , 2005 .
[156] M. Surowiec,et al. Calix[4]arene-dithiacrown ethers: synthesis and potentiometric membrane sensing of Hg2+ , 2010 .
[157] H. Lang,et al. Ni(2+) selective sensors based on meso-tetrakis-{4-[tris-(4-allyl dimethylsilyl-phenyl)-silyl]-phenyl}porphyrin and (sal)(2)trien in poly(vinyl chloride) matrix. , 2007, Talanta.
[158] Sunita Kumar,et al. Iron (III) Selective Electrode Based on S-Methyl N-(Methylcarbamoyloxy) Thioacetimidate as a Sensing Material , 2011, International Journal of Electrochemical Science.
[159] V. Gupta,et al. Electroanalytical studies on cobalt(II) selective potentiometric sensor based on bridge modified calixarene in poly(vinyl chloride) , 2008 .
[160] M. Shamsipur,et al. Cadmium ion-selective electrode based on tetrathia-12-crown-4. , 2001, Talanta.
[161] Ashutosh Kumar Singh,et al. Zn(II)‐Selective Membrane Electrode Based on Tetraazamacrocycle [Bzo2Me2Ph2(16)hexaeneN4] , 2006 .
[162] L. Singh,et al. Molybdate sensor based on 5,10,15,20-tetraphenylporphyrinatocobalt complex in a PVC matrix , 1999 .
[163] Archana Singh,et al. Cobalt(II)-selective electrode based on a newly synthesized macrocyclic compound , 2006 .
[164] S. Hassan,et al. Mercury(II) ion-selective polymeric membrane sensors for analysis of mercury in hazardous wastes. , 2006, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[165] Ernö Pretsch,et al. Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics. , 1997, Chemical reviews.
[166] J. Bobacka,et al. New polyacrylate-based lead(II) ion-selective electrodes , 2009 .
[167] Soraia Meghdadi,et al. A Highly Selective Mercury(II) Ion-Selective Membrane Sensor , 2007 .
[168] Ewa Bulska,et al. Poly(n-butyl acrylate) based lead (II) selective electrodes. , 2009, Talanta.
[169] M. Ganjali,et al. Determination of zinc(II) ions in waste water samples by a novel zinc sensor based on a new synthesized Schiff's base , 2011 .
[170] Vinod K. Gupta,et al. Preparation of ethambutol-copper(II) complex and fabrication of PVC based membrane potentiometric sensor for copper. , 2003, Talanta.
[171] A. Abbaspour,et al. A highly selective and sensitive disposable carbon composite PVC-based membrane for determination of lead ion in environmental samples. , 2010, Journal of hazardous materials.
[172] Mohamed A. F. Elmosallamy,et al. Lead(II) Potentiometric Sensor Based on 1,4,8,11‐Tetrathiacyclotetradecane Neutral Carrier and Lipophilic Additives , 2008 .
[173] Zaide Zhou,et al. Mercury(II)-selective polymeric membrane electrode based on the 3-[4-(dimethylamino)phenyl]-5-mercapto-1,5-diphenylpentanone , 2007 .
[174] Ashutosh Kumar Singh,et al. A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of N,N'-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine. , 2006, Analytica chimica acta.
[175] M. Shamsipur,et al. A new PVC-based 1,10-dibenzyl-1,10-diaza-18-crown-6 selective electrode for detecting nickel(II)ion , 2000 .
[176] E. Kılıç,et al. Silver(I)‐Selective PVC Membrane Potentiometric Sensor Based on a Recently Synthesized Calix[4]arene , 2006 .
[177] R. Conyers,et al. Determination of silver in blood, urine, and tissues of volunteers and burn patients. , 1991, Clinical chemistry.
[178] M. Ganjali,et al. Determination of copper in black, red pepper and the waste water samples by a highly selective sensitive Cu(II) microelectrode based on a new hexadentates Schiff's base , 2006 .
[179] A. Mittal,et al. Adsorption of basic fuchsin using waste materials--bottom ash and deoiled soya--as adsorbents. , 2008, Journal of colloid and interface science.
[180] Ashutosh Kumar Singh,et al. Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases. , 2009, Analytica chimica acta.
[181] M. K. Rofouei,et al. Mercury(II) selective membrane electrode based on 1,3-bis(2-methoxybenzene)triazene , 2009 .
[182] Terence E. Rice,et al. Signaling Recognition Events with Fluorescent Sensors and Switches. , 1997, Chemical reviews.
[183] M. Bagheri,et al. Hg2+‐Selective Membrane Potentiometric Sensor Based on a Recently Synthesized Mercapto Compound , 2003 .
[184] V. Gupta,et al. Advances in water treatment by adsorption technology , 2006, Nature Protocols.
[185] A. Jain,et al. A PVC Based Hematoporphyrin IX Membrane Potentiometric Sensor for Zinc(II) , 2002 .
[186] O. Sánchez,et al. Mercury(II) ion-selective electrode. Study of 1,3-diphenylthiourea as ionophore , 2000 .
[187] H. Sharghi,et al. Zinc-selective membrane potentiometric sensor based on a recently synthesized benzo-substituted macrocyclic diamide , 1999 .
[188] Soraia Meghdadi,et al. Sensitive cadmium potentiometric sensor based on 4-hydroxy salophen as a fast tool for water samples analysis , 2009 .
[189] Ashutosh Kumar Singh,et al. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples , 2008, Analytical and bioanalytical chemistry.
[190] Vinod K. Gupta,et al. Chloride selective potentiometric sensor based on a newly synthesized hydrogen bonding anion receptor , 2009 .
[191] R. Ludwig,et al. Anion recognition through modified calixarenes: a highly selective sensor for monohydrogen phosphate , 2005 .
[192] Ashutosh Kumar Singh,et al. Chromium(III)-selective electrode based on a macrocyclic compound , 1999 .
[193] S. Chandra,et al. PVC-based heterogeneous chelating inorganic exchanger membrane as sensors for the determination of zinc(II) ions , 2006 .
[194] S. Jeon,et al. Polymeric Lead(II)-selective Electrode Based on N,N'-Bis-thiophen-2-ylmethylene-pyridine-2,6-diamine as an Ion Carrier , 2007 .
[195] H. Khani,et al. Multi-walled carbon nanotubes-ionic liquid-carbon paste electrode as a super selectivity sensor: application to potentiometric monitoring of mercury ion(II). , 2010, Journal of hazardous materials.
[196] M. Shamsipur,et al. Cadmium(II)-selective membrane electrode based on a synthesized tetrol compound , 2000 .
[197] G. Shen,et al. 5,10,15-Tris(pentafluorophenyl)corrole as highly selective neutral carrier for a silver ion-sensitive electrode , 2006 .
[198] Mei-Rong Huang,et al. Lead(II) ion-selective electrode based on polyaminoanthraquinone particles with intrinsic conductivity. , 2009, Talanta.
[199] S. Mittal,et al. Potentiometric studies of N,N′-Bis(2-dimethylaminoethyl)-N,N′-dimethyl-9,10 anthracenedimethanamine as a chemical sensing material for Zn(II) ions , 2008 .
[200] E. Merian,et al. Metals and their compounds in the environment: Occurrence, analysis, and biological relevance , 1991 .
[201] M. H. Mashhadizadeh,et al. Nickel(II)-selective membrane potentiometric sensor using a recently synthesized Schiff base as neutral carrier , 2003 .
[202] A. Cukurovali,et al. A highly sensitive and selective fluorescent sensor for the determination of copper(II) based on a schiff base , 2009 .
[203] Mojtaba Shamsipur,et al. Lead-selective poly(vinyl chloride) electrodes based on some synthesized benzo-substituted macrocyclic diamides. , 2009, Journal of hazardous materials.
[204] A. Pombeiro,et al. Poly(vinyl) chloride membrane copper-selective electrode based on 1-phenyl-2-(2-hydroxyphenylhydrazo)butane-1,3-dione. , 2011, Journal of hazardous materials.
[205] A. Abbaspour,et al. Copper(II)-selective electrode based on dithioacetal , 2002 .
[206] M. K. Amini,et al. Pentacyclooctaaza as a neutral carrier in coated-wire ion-selective electrode for nickel(II) , 2002 .
[207] Ashutosh Kumar Singh,et al. Selective electrochemical sensor for copper (II) ion based on chelating ionophores. , 2006, Analytica chimica acta.