Power amplifier circuits for functional electrical stimulation systems

Introduction: Functional electrical stimulation (FES) is a technique that has been successfully employed in rehabilitation treatment to mitigate problems after spinal cord injury (SCI). One of the most relevant modules in a typical FES system is the power or output amplifier stage, which is responsible for the application of voltage or current pulses of proper intensity to the biological tissue, applied noninvasively via electrodes, placed on the skin surface or inside the muscular tissue, closer to the nervous fibers. The goals of this paper are to describe and discuss about the main power output designs usually employed in transcutaneous functional electrical stimulators as well as safety precautions taken to protect patients. Methods: A systematic review investigated the circuits of papers published in IEEE Xplore and ScienceDirect databases from 2000 to 2016. The query terms were “((FES or Functional electric stimulator) and (circuit or design))” with 274 papers retrieved from IEEE Xplore and 29 from ScienceDirect. After the application of exclusion criteria the amount of papers decreased to 9 and 2 from IEEE Xplore and ScienceDirect, respectively. One paper was inserted in the results as a technological contribution to the field. Therefore, 12 papers presented power stage circuits suitable to stimulate great muscles. Discussion: The retrieved results presented relevant circuits with different electronic strategies and circuit components. Some of them considered patient safety strategies or aimed to preserve muscle homeostasis such as biphasic current application, which prevents charge accumulation in stimulated tissues as well as circuits that dealt with electrical impedance variation to keep the electrode-tissue interface within an electrochemical safe regime. The investigation revealed a predominance of design strategies using operational amplifiers in power circuits, current outputs, and safety methods to reduce risks of electrical hazards and discomfort to the individual submitted to FES application.

[1]  Katsuhiko Ogata,et al.  Modern control engineering (3rd ed.) , 1996 .

[2]  Ting Wang,et al.  Development of a network FES system for stroke rehabilitation , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Jader A. De Lima,et al.  A low-cost neurostimulator with accurate pulsed-current control , 2002, IEEE Transactions on Biomedical Engineering.

[4]  A. Seireg,et al.  Electrical parameters for over-the-skin muscle stimulation. , 1981, Journal of biomechanics.

[5]  A. Masdar,et al.  Development of wireless-based low-cost current controlled stimulator for patients with spinal cord injuries , 2012, 2012 IEEE-EMBS Conference on Biomedical Engineering and Sciences.

[6]  A. Maleki,et al.  Developing a stimulator and an interface for FES-cycling rehabilitation system , 2011, 2011 18th Iranian Conference of Biomedical Engineering (ICBME).

[7]  K.W.E. Cheng,et al.  Development of a circuit for functional electrical stimulation , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  Qi Xu,et al.  A programmable multi-channel stimulator for array electrodes in transcutaneous electrical stimulation , 2011, The 2011 IEEE/ICME International Conference on Complex Medical Engineering.

[9]  Han-Chang Wu,et al.  A versatile multichannel direct-synthesized electrical stimulator for FES applications , 2002, IEEE Trans. Instrum. Meas..

[10]  Ya-Hsin Hsueh,et al.  Design of high voltage digital-to-analog converter for electrical stimulator , 2012, 2012 IEEE Asia Pacific Conference on Circuits and Systems.

[11]  Xiaoxiang Zheng,et al.  A self-adaptive foot-drop corrector using functional electrical stimulation (FES) modulated by tibialis anterior electromyography (EMG) dataset. , 2013, Medical engineering & physics.

[12]  Michael P. Willand,et al.  Design and testing of an instrumentation system to reduce stimulus pulse amplitude requirements during FES , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  John G. Webster,et al.  Electronic devices for rehabilitation , 1985 .

[14]  R. Stein,et al.  Electrical stimulation: can it increase muscle strength and reverse osteopenia in spinal cord injured individuals? , 2000, Archives of physical medicine and rehabilitation.

[15]  A. Prodic,et al.  A universal functional electrical stimulator based on merged flyback-SC circuit , 2012, 2012 15th International Power Electronics and Motion Control Conference (EPE/PEMC).

[16]  J. L. Pons,et al.  Enhancing functional electrical stimulation for emerging rehabilitation robotics in the framework of hyper project , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[17]  Medhat A. Moussa,et al.  BioMEMS implants for neural regeneration after a spinal cord injury , 2005, 2005 International Conference on MEMS,NANO and Smart Systems.

[18]  M.N. Souza,et al.  A Programmable System of Functional Electrical Stimulation (FES) , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[19]  Ulrich G. Hofmann,et al.  Dynamically adjusted, scalable electrical stimulator for exciteable tissue , 2015, 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER).

[20]  Daniel R. Merrill,et al.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols , 2005, Journal of Neuroscience Methods.

[21]  E. Cardiel,et al.  Electrical stimulator for surface nerve stimulation by using modulated pulses , 2011, 2011 Pan American Health Care Exchanges.