The Effect of Prosthesis Design on Vibration of the Reconstructed Ossicular Chain: A Comparative Finite Element Analysis of Four Prostheses

Hypothesis It was hypothesized that the differences in the bioacoustic performance of ossicular replacement prosthesis designs, and insertion positions, could be quantified using finite element analysis. Background Many designs of prosthesis are available for middle ear surgery. The materials used, and the shape of the implants, differ widely. Advances in computer simulation technologies offer the possibility of replicating the in vivo behavior of the different prostheses. If this can be achieved, insight into the design attributes required for improved biofunctionality may be gained. Methods Micro-computed tomography and nuclear magnetic resonance imaging were used to obtain geometric information that was translated into a finite element model of the outer and middle ear. The forced frequency response across the hearing range of the normal middle ear was compared with the middle ear reconstructed with partial and total ossicular replacement prostheses. Results The amplitude of vibration of the footplate was more similar to that of the normal ear when a Kurz total ossicular replacement prosthesis was implanted than when a Xomed total ossicular replacement prosthesis was implanted. This may be attributed to the latter's titanium link. Partial ossicular replacement prostheses were stiffest and had lower umbo vibrations and higher stapedial footplate vibrations. In all cases but one, the vibration of the prostheses had resonances that caused the vibration of the stapes footplate to be noticeably different from normal. Conclusion The authors confirmed the hypothesis that finite element modeling can be used to predict the differences in the response of ossicular replacement prostheses. This study shows that computer simulation can potentially be used to test or optimize the vibroacoustic characteristics of middle ear implants.

[1]  M. Vlaming,et al.  Studies on the mechanics of the reconstructed human middle ear. , 1986, Clinical otolaryngology and allied sciences.

[2]  M. Walger,et al.  Standardized measurements of the sound transmission of middle ear implants using a mechanical middle ear model , 1999, European Archives of Oto-Rhino-Laryngology.

[3]  John J. Rosowski,et al.  Acoustic input impedance of the stapes and cochlea in human temporal bones , 1996, Hearing Research.

[4]  J. Ito,et al.  Suppression of tinnitus by cochlear implantation. , 1994, American journal of otolaryngology.

[5]  切替 一郎,et al.  The structure and function of the middle ear , 1960 .

[6]  I. Tuncer,et al.  Inverted follicular keratosis. , 1993, American journal of otolaryngology.

[7]  Larry L. Hench,et al.  Clinical performance of skeletal prostheses , 1995 .

[8]  A Eiber,et al.  Dynamics of Middle Ear Prostheses – Simulations and Measurements , 1999, Audiology and Neurotology.

[9]  W R Funnell,et al.  Finite-element modeling of the normal and surgically repaired cat middle ear. , 1996, The Journal of the Acoustical Society of America.

[10]  G. Ball,et al.  Measurement of umbo vibration in human subjects--method and possible clinical applications. , 1993, The American journal of otology.

[11]  Patrick J. Prendergast,et al.  Vibro-Acoustic Modelling of the Outer and Middle Ear Using the Finite-Element Method , 1999, Audiology and Neurotology.

[12]  R. Goode,et al.  Experimental models of ossiculoplasty. , 1994, Otolaryngologic clinics of North America.

[13]  P J Prendergast,et al.  Middle-ear dynamics before and after ossicular replacement. , 2000, Journal of biomechanics.

[14]  M. Portmann,et al.  Problems in alloplastic middle ear reconstruction. , 1992, Acta oto-laryngologica.

[15]  H Wada,et al.  Analysis of dynamic behavior of human middle ear using a finite-element method. , 1992, The Journal of the Acoustical Society of America.

[16]  M. Vlaming,et al.  Studies on the mechanics of the normal human middle ear. , 1986, Clinical otolaryngology and allied sciences.

[17]  J. Verheul,et al.  FUNCTION AND MECHANICS OF NORMAL, DISEASED AND RECONSTRUCTED MIDDLE EARS , 2000 .

[18]  K Nakamura,et al.  New knowledge about the function of the human middle ear: development of an improved analog model. , 1994, The American journal of otology.

[19]  Frederic Martini,et al.  Fundamentals of Anatomy and Physiology , 1997 .

[20]  K. Lobel Ossicular Replacement Prostheses , 1996 .

[21]  G. J. McAvoy,et al.  The development of a vibro-acoustic model of the human ear , 1995 .

[22]  S. Puria Middle Ear Mechanics in Research and Otosurgery: Proceedings of the International Workshop on Middle Ear Mechanics and Otosurgery, Dresden, Germany, September 19–22, 1996, Karl-Bernd Hüttenbrink (Ed.). Bibliothek der HNO-Universitätsklinik, Dresden, Germany, 1997. ISBN 3-86005-193-8. , 1999 .