Ventilatory thresholds assessment from heart rate variability during an incremental exhaustive running test.

The present study examined whether the ventilatory thresholds during an incremental exhaustive running test could be determined using heart rate variability (HRV) analysis. Beat-to-beat RR interval, V(.-)O (2), V(.-)CO (2) and V(.-) (E) of twelve professional soccer players were collected during an incremental test performed on a track until exhaustion. The "smoothed pseudo Wigner-Ville distribution" (SPWVD) time-frequency analysis method was applied to the RR time series to compute the usual HRV components vs. running speed stages. The ventilatory equivalent method was used to assess the ventilatory thresholds (VT1 and VT2) from respiratory components. In addition, ventilatory thresholds were assessed from the instantaneous components of respiratory sinus arrhythmia (RSA) by two different methods: 1) from the high frequency peak of HRV ( FHF), and 2) from the product of the spectral power contained within the high frequency band (0.15 Hz to fmax) by FHF (HF x FHF) giving two thresholds: HFT1 and HFT2. Since the relationship between FHF and running speed was linear for all subjects, the VTs could not be determined from FHF. No significant differences were found between respective running speeds at VT1 vs. HFT1 (9.83 +/- 1.12 vs. 10.08 +/- 1.29 km x h (-1), n.s.) nor between the respective running speeds at VT2 vs. HFT2 (12.55 +/- 1.31 vs. 12.58 +/- 1.33 km x h (-1), n.s.). Linear regression analysis showed a strong correlation between VT1 vs. HFT1 (R (2) = 0.94, p < 0.001) and VT2 vs. HFT2 (R (2) = 0.96, p < 0.001). The Bland-Altman plot analysis reveals that the assessment from RSA gives an accurate estimation of the VTs, with HF x FHF providing a reliable index for the ventilatory thresholds detection. This study has shown that VTs could be assessed during an incremental running test performed on a track using a simple beat-to-beat heart rate monitor, which is less expensive and complex than the classical respiratory measurement devices.

[1]  R. Gelfand,et al.  Breathing patterns during submaximal and maximal exercise in elite oarsmen. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.

[2]  J. Duffin,et al.  Changes in ventilation in response to ramp changes in treadmill exercise load , 2004, European Journal of Applied Physiology and Occupational Physiology.

[3]  R. Hughson,et al.  Autonomic nervous system responses to exercise in relation to ventilatory threshold. , 1992, Chest.

[4]  K. R. Williams Biomechanics of Running , 1985, Exercise and sport sciences reviews.

[5]  S. Gaskill,et al.  Validity and reliability of combining three methods to determine ventilatory threshold. , 2001, Medicine and science in sports and exercise.

[6]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[7]  S. Iscoe,et al.  Synchronization of respiratory frequency by somatic afferent stimulation. , 1976, Journal of applied physiology.

[8]  R. Hughson,et al.  Autonomic control of heart rate during exercise studied by heart rate variability spectral analysis. , 1991, Journal of applied physiology.

[9]  Y. Papelier,et al.  Effects of Exercise Load and Breathing Frequency on Heart Rate and Blood Pressure Variability During Dynamic Exercise , 1999, International journal of sports medicine.

[10]  B R Londeree,et al.  Effect of training on lactate/ventilatory thresholds: a meta-analysis. , 1997, Medicine and science in sports and exercise.

[11]  K. Wasserman,et al.  DETECTING THE THRESHOLD OF ANAEROBIC METABOLISM IN CARDIAC PATIENTS DURING EXERCISE. , 1964, The American journal of cardiology.

[12]  A Calciati,et al.  Determinants of respiratory sinus arrhythmia in the vagotomized rabbit. , 1995, The American journal of physiology.

[13]  L. Rowell Human Cardiovascular Control , 1993 .

[14]  G. Cavagna,et al.  Mechanical power and efficiency in running children , 2001, Pflügers Archiv.

[15]  J. Nw,et al.  Determination of Anaerobic Threshold by Ventilatory Frequency* , 1989, International journal of sports medicine.

[16]  J. Durnin,et al.  Body fat assessed from total body density and its estimation from skinfold thickness: measurements on 481 men and women aged from 16 to 72 Years , 1974, British Journal of Nutrition.

[17]  T. Streubel,et al.  Mechanosensitive cells in the atrium of frog heart , 1992, Experimental physiology.

[18]  B. Shultz,et al.  An evaluation of the predictive validity and reliability of ventilatory threshold. , 2004, Medicine and science in sports and exercise.

[19]  M. Bonsignore,et al.  Ventilation and entrainment of breathing during cycling and running in triathletes. , 1998, Medicine and science in sports and exercise.

[20]  O Meste,et al.  Assessment of ventilatory thresholds during graded and maximal exercise test using time varying analysis of respiratory sinus arrhythmia , 2005, British Journal of Sports Medicine.

[21]  W L Beaver,et al.  Anaerobic threshold and respiratory gas exchange during exercise. , 1973, Journal of applied physiology.

[22]  S. Loring,et al.  Determinants of breathing frequency during walking. , 1990, Respiration physiology.

[23]  L. Léger,et al.  A maximal multistage 20-m shuttle run test to predict $$\dot V$$ O2 max , 2004, European Journal of Applied Physiology and Occupational Physiology.

[24]  Pontus B. Persson,et al.  High-frequency oscillations of the heart rate during ramp load reflect the human anaerobic threshold , 2000, European Journal of Applied Physiology.

[25]  A. Caiazza,et al.  Is respiratory sinus arrhythmia a good index of cardiac vagal tone in exercise? , 1996, Journal of applied physiology.

[26]  J. Lacour,et al.  [Role of aerobic metabolism in prolonged intensive exercise]. , 1977, Journal of Physiology.

[27]  Claire Médigue,et al.  Instantaneous parameter estimation in cardiovascular time series by harmonic and time-frequency analysis , 2002, IEEE Transactions on Biomedical Engineering.

[28]  David T. Martin,et al.  Evaluation of the Lactate Pro blood lactate analyser , 2000, European Journal of Applied Physiology.

[29]  P. Bernasconi,et al.  Analysis of co‐ordination between breathing and exercise rhythms in man. , 1993, The Journal of physiology.

[30]  A. Varray,et al.  Respiratory gas exchange indices used to detect the blood lactate accumulation threshold during an incremental exercise test in young athletes , 2004, European Journal of Applied Physiology and Occupational Physiology.

[31]  Y. Papelier,et al.  Heart rate variability during cycloergometric exercise or judo wrestling eliciting the same heart rate level , 2004, European Journal of Applied Physiology.

[32]  T. Seppänen,et al.  Quantitative beat-to-beat analysis of heart rate dynamics during exercise. , 1996, The American journal of physiology.

[33]  U Reinhard,et al.  Determination of anaerobic threshold by the ventilation equivalent in normal individuals. , 1979, Respiration; international review of thoracic diseases.

[34]  A. Ruha,et al.  A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV , 1997, IEEE Transactions on Biomedical Engineering.

[35]  H. Huikuri,et al.  Changes in cardiac autonomic regulation after prolonged maximal exercise. , 2001, Clinical physiology.