Airflow and heat transfer in double skin facades

Abstract Airflow and heat transfer simulation was conducted for a DSF system equipped with a venetian blind, using computational fluid dynamics (CFD) with RNG turbulence model, for a three-level combination of slat tilt angle and blind position. The CFD prediction was validated using experimental data collected for a mechanically ventilated DSF equipped with venetian blinds. The predicted trends in glass and blind surface temperatures of the CFD model are compared well with the experimental measurements. The present study indicates that the presence of venetian blinds influences the surface heat transfer coefficients (SHTCs), the temperature and the air distribution in the DSF system. For the cases considered, the changes in the position of the blinds (outer, middle, and inner) have more effect on the distribution of temperature, velocity, and SHTCs compared to the changes in the slat angles ( θ  = 0°, 45°, 90°).

[1]  H. Manz Total solar energy transmittance of glass double façades with free convection , 2004 .

[2]  Carla Balocco,et al.  A non-dimensional analysis of a ventilated double façade energy performance , 2004 .

[3]  André De Herde,et al.  The most efficient position of shading devices in a double-skin facade , 2007 .

[4]  David Infield,et al.  Façades and summer performance of buildings , 2008 .

[5]  Nader Sadegh,et al.  Calibration of a lumped simulation model for double-skin façade systems , 2004 .

[6]  A. Schaelin,et al.  Airflow patterns and thermal behavior of mechanically ventilated glass double façades , 2004 .

[7]  F. Haghighat,et al.  Modeling ventilated double skin façade—A zonal approach , 2008 .

[8]  Jun Tanimoto,et al.  Simulation study on an air flow window system with an integrated roll screen , 1997 .

[9]  Martin Lutz,et al.  Double-Skin Facades: Integrated Planning , 2001 .

[10]  Hidayat Shahid,et al.  Energy performance assessment of a window with a horizontal Venetian blind , 2005 .

[11]  A.H.C. van Paassen,et al.  Symbiosis of the double skin facade with the HVAC system , 2005 .

[12]  A. Oliva,et al.  Numerical analysis of the thermal behaviour of glazed ventilated facades in Mediterranean climates. Part II: applications and analysis of results , 2003 .

[13]  André De Herde,et al.  Natural ventilation in a double-skin facade , 2004 .

[14]  Monika Woloszyn,et al.  Three-dimensional simulation with a CFD tool of the airflow phenomena in single floor double-skin facade equipped with a venetian blind , 2005 .