Formation of Hydroxyapatite Layer on Ti-6Al-4V ELI Alloy by Fine Particle Peening
暂无分享,去创建一个
Yuki Nakamura | Shoichi Kikuchi | Koichiro Nambu | Toshikazu Akahori | Yuki Nakamura | S. Kikuchi | T. Akahori | K. Nambu
[1] 潤 小茂鳥,et al. Ti-6Al-4V 合金の大気酸化挙動に及ぼす微粒子ピーニングの影響 , 2015 .
[2] L. Sexton,et al. Deposition of substituted apatites onto titanium surfaces using a novel blasting process , 2009 .
[3] K. Asaoka,et al. Blast coating method: new method of coating titanium surface with hydroxyapatite at room temperature. , 1997, Journal of biomedical materials research.
[4] Kaan Erkorkmaz,et al. Machining Porous Calcium Polyphosphate Implants for Tissue Engineering Applications , 2010, Int. J. Autom. Technol..
[5] Y. Kameyama,et al. Effect of fine particle peening using carbon-black/steel hybridized particles on tribological properties of stainless steel , 2014 .
[6] Hitoshi Ohmori,et al. Fabrication of micro-textured and plateau-processed functional surface by angled fine particle peening followed by precision grinding , 2015 .
[7] B. Previtali,et al. High tolerance plasma arc cutting of commercially pure titanium , 2005 .
[8] T. Kuriyagawa,et al. Characteristics of hydroxyapatite film formed on human enamel with the powder jet deposition technique. , 2011, Journal of biomedical materials research. Part B, Applied biomaterials.
[9] Takashi Nakamura,et al. Surface potential change in bioactive titanium metal during the process of apatite formation in simulated body fluid. , 2003, Journal of biomedical materials research. Part A.
[10] Y. Yokogawa,et al. Bond strength improvement of hydroxyapatite/titanium composite coating by partial nitriding during RF-thermal plasma spraying , 2003 .
[11] Yuki Nakamura,et al. Effect of shot peening using ultra-fine particles on fatigue properties of 5056 aluminum alloy under rotating bending , 2016 .
[12] T. Kuriyagawa,et al. Effect of hydroxyapatite film formed by powder jet deposition on dentin permeability. , 2012, European journal of oral sciences.
[13] J. Kärrholm,et al. Effects of hydroxyapatite coating of cups used in hip revision arthroplasty , 2012, Acta orthopaedica.
[14] H. Rack,et al. Titanium alloys in total joint replacement--a materials science perspective. , 1998, Biomaterials.
[15] B. Castanié,et al. Influence of Machining Process and Machining Induced Surface Roughness on Mechanical Properties of Continuous Fiber Composites , 2015 .
[16] Q. Luo,et al. High-precision determination of residual stress of polycrystalline coatings using optimised XRD-sin2ψ technique , 2010 .
[17] J. Komotori,et al. Effect of micro ploughing during fine particle peening process on the microstructure of metallic materials , 2009 .
[18] Y. Ueyama,et al. Initial tissue response to a titanium implant coated with apatite at room temperature using a blast coating method. , 2002, Biomaterials.
[19] Masayoshi Mizutani,et al. Improved Cytocompatibility of Nanosecond-Pulsed Laser-Treated Commercially Pure Ti Surfaces , 2014, Int. J. Autom. Technol..
[20] H. Akebono,et al. Surface modification of carbon steel by atmospheric-controlled IH-FPP treatment using mixed chromium and high-speed steel particles , 2016 .
[21] Brad L. Boyce,et al. Effect of load ratio and maximum stress intensity on the fatigue threshold in Ti–6Al–4V , 2001 .
[22] Robert B. Heimann,et al. Thermal spraying of biomaterials , 2006 .
[23] R. Ritchie,et al. Influence of microstructure on high-cycle fatigue of Ti-6Al-4V: Bimodal vs. lamellar structures , 2002 .
[24] Y. Mutoh,et al. Acoustic emission and fatigue damage induced in plasma-sprayed hydroxyapatite coating layers. , 2012, Journal of the mechanical behavior of biomedical materials.
[25] D. Eifler,et al. Analysis of fatigue properties and failure mechanisms of Ti6Al4V in the very high cycle fatigue regime using ultrasonic technology and 3D laser scanning vibrometry. , 2013, Ultrasonics.
[26] Tadashi Kokubo,et al. Spontaneous Formation of Bonelike Apatite Layer on Chemically Treated Titanium Metals , 1996 .
[27] Y. Mutoh,et al. Failure behavior of plasma-sprayed HAp coating on commercially pure titanium substrate in simulated body fluid (SBF) under bending load. , 2012, Journal of the mechanical behavior of biomedical materials.
[28] S. Kikuchi,et al. Analysis of pneumatic fine particle peening process by using a high-speed-camera , 2010 .
[29] P. A. Blenkinsop,et al. Internal fatigue origins in α-β titanium allols , 1976 .
[30] F. Eyma,et al. Study of trimming damages of CFRP structures in function of the machining processes and their impact on the mechanical behavior , 2014 .
[31] Yuki Nakamura,et al. Characterization of the hydroxyapatite layer formed by fine hydroxyapatite particle peening and its effect on the fatigue properties of commercially pure titanium under four-point bending , 2016 .
[32] E. van der Velde,et al. In vivo tensile testing of fluorapatite and hydroxylapatite plasma-sprayed coatings. , 1994, Journal of biomedical materials research.
[33] Y. Nakai,et al. Effect of harmonic structure design with bimodal grain size distribution on near-threshold fatigue crack propagation in Ti–6Al–4V alloy , 2016 .
[34] S. Kikuchi,et al. Increasing Surface Hardness of AISI 1045 Steel by AIH-FPP/Plasma Nitriding Treatment , 2013 .
[35] R. Reis,et al. Crystallinity and structural changes in HA plasma-sprayed coatings induced by cyclic loading in physiological media , 1996 .
[36] T. Morita,et al. Effects of Fine Particle Bombarding on Surface Characteristics and Fatigue Strength of Commercial Pure Titanium , 2012 .
[37] S. M. Wong. Residual stress measurements on chromium films by x-ray diffraction using the sin2ψ method , 1978 .
[38] S. Komarov,et al. Fabrication of hydroxyapatite coatings by the ball impact process , 2012 .
[39] T. Morita,et al. Effect of combination treatment on wear resistance and strength of Ti–6Al–4V alloy , 2014 .