Direct introduction of aqueous eluents for on–line coupled liquid chromatography–capillary gas chromatography

The on-line introduction of relatively large volumes of reversed-phase (aqueous) eluents into a capillary GC column without severe distortion of components eluting at temperatures close to the solvent boiling point is described. The technique, which utilizes an uncoated inlet (retention gap), is based on complete evaporation of the solvent prior to reaching the stationary phase and introduction of components with a dispersion equivalent to that given by a micro-LC system. Studies of the evaporation within the retention gap, accomplished by introduction of a nonvolatile dye and visual examination of the resulting band patterns, indicated minimum retention gap lengths necessary to prevent liquid solvent from reaching the capillary GC column when aqueous eluents are used. The determination of N-Serve' (2-chloro-6-[trichloro methyl]pyridine) in corn extract is described.

[1]  T. Noy,et al.  On-line combination of liquid chromatography and capillary gas chromatography : preconcentration and analysis of organic compounds in aqueous samples , 1988 .

[2]  K. Grob,et al.  Minimum column temperature required for concurrent solvent evaporation in coupled HPLC-GC , 1987 .

[3]  T. S. Stevens,et al.  Porous ceramic bed supports for fused silica packed capillary columns used in liquid chromatography , 1987 .

[4]  G. J. Jong,et al.  Liquid chromatographic trace enrichment with on‐line capillary gas chromatography for the determination of organic pollutants in aqueous samples , 1987 .

[5]  K. Grob,et al.  Uncoated capillary column inlets (retention gaps) in gas chromatography. , 1987, Journal of chromatography.

[6]  V. Pretorius,et al.  Stationary‐phase swelling and its consequences in capillary gas‐liquid chromatography , 1986 .

[7]  K. Grob,et al.  Concurrent solvent evaporation for on‐line coupled HPLC‐HRGC , 1986 .

[8]  D. Jensen,et al.  Determination of trace chlorinated benzenes in fuel oil by on-line multidimensional chromatography using packed-capillary liquid chromatography and capillary gas chromatography , 1985 .

[9]  B. Richter,et al.  On‐line multidimensional chromatography using packed capillary liquid chromatography and capillary gas chromatography , 1985 .

[10]  W. Jennings,et al.  Developments in the Analysis of Headspace Volatiles: On-Column Injections into Fused Silica Capillaries and Split Injections with a Low-Temperature Bonded PEG Stationary Phase , 1984 .

[11]  H. Neukom,et al.  Coupling of high-performance liquid chromatography with capillary gas chromatography , 1984 .

[12]  K. Grob Solvent effects in capillary gas chromatography , 1983 .

[13]  K. Grob,et al.  Broadening of peaks eluted before the solvent in capillary GC Part II: The role of phase soaking , 1983 .

[14]  V. Pretorius,et al.  Solute focusing, in GLC, using the solvent effect: A general description , 1983 .

[15]  V. Pretorius,et al.  Sample introduction in capillary gas-liquid chromatography , 1983 .

[16]  B. W. Wright,et al.  Characterization of glass, quartz, and fused silica capillary column surfaces from contact-angle measurements , 1981 .

[17]  J. Conder Thermodynamic measurement by gas chromatography at finite solute concentration , 1974 .