Direct Integration of Battery Energy Storage Systems in Distributed Power Generation

In this paper, a wind energy conversion system interfaced to the grid using a dual inverter is proposed. One of the two inverters in the dual inverter is connected to the rectified output of the wind generator while the other is directly connected to a battery energy storage system (BESS). This approach eliminates the need for an additional dc-dc converter and thus reduces power losses, cost, and complexity. The main issue with this scheme is uncorrelated dynamic changes in dc-link voltages that results in unevenly distributed space vectors. A detailed analysis on the effects of these variations is presented in this paper. Furthermore, a modified modulation technique is proposed to produce undistorted currents even in the presence of unevenly distributed and dynamically changing space vectors. An analysis on the battery charging/discharging process and maximum power point tracking of the wind turbine generator is also presented. Simulation and experimental results are presented to verify the efficacy of the proposed modulation technique and battery charging/discharging process.

[1]  Zhiping Qi,et al.  Research on Battery Supercapacitor Hybrid Storage and its application in MicroGrid , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[2]  Xinbo Ruan,et al.  Three-Level Bidirectional Converter for Fuel-Cell/Battery Hybrid Power System , 2010, IEEE Transactions on Industrial Electronics.

[3]  X.Y. Wang,et al.  Determination of Battery Storage Capacity in Energy Buffer for Wind Farm , 2008, IEEE Transactions on Energy Conversion.

[4]  U. K. Madawala,et al.  A new method of interfacing battery/supercapacitor energy storage systems for distributed energy sources , 2010, 2010 Conference Proceedings IPEC.

[5]  J.P. Barton,et al.  Energy storage and its use with intermittent renewable energy , 2004, IEEE Transactions on Energy Conversion.

[6]  D. Casadei,et al.  Multilevel Operation and Input Power Balancing for a Dual Two-Level Inverter with Insulated DC Sources , 2008, IEEE Transactions on Industry Applications.

[7]  G. Joos,et al.  Comparison of Energy Storage System Technologies and Configurations in a Wind Farm , 2007, 2007 IEEE Power Electronics Specialists Conference.

[8]  Mike Barnes,et al.  Power quality and stability improvement of a wind farm using STATCOM supported with hybrid battery energy storage , 2006 .

[9]  U. K. Madawala,et al.  Space vector modulated cascade multi-level inverter for PMSG wind generation systems , 2009, 2009 35th Annual Conference of IEEE Industrial Electronics.

[10]  Bhim Singh,et al.  Autonomous hybrid system using SCIG for hydro power generation and variable speed PMSG for wind power generation , 2009, 2009 International Conference on Power Electronics and Drive Systems (PEDS).

[11]  R. Uma,et al.  BESS Based Voltage and Frequency Controller for Stand Alone Wind Energy Conversion System Employing PMSG , 2009, 2009 IEEE Industry Applications Society Annual Meeting.

[12]  Gabriele Grandi,et al.  Dual inverter space vector modulation with power balancing capability , 2009, IEEE EUROCON 2009.

[13]  Subhashish Bhattacharya,et al.  Optimal Control of Battery Energy Storage for Wind Farm Dispatching , 2010, IEEE Transactions on Energy Conversion.

[14]  B. R. Alamri,et al.  Technical review of energy storage technologies when integrated with intermittent renewable energy , 2009, 2009 International Conference on Sustainable Power Generation and Supply.

[15]  A. Bouscayrol,et al.  Influence of control strategies on battery/supercapacitor hybrid Energy Storage Systems for traction applications , 2009, 2009 IEEE Vehicle Power and Propulsion Conference.

[16]  Domenico Casadei,et al.  A New Multilevel Conversion Structure for Grid-Connected PV Applications , 2009, IEEE Transactions on Industrial Electronics.

[17]  D. Casadei,et al.  Multilevel Operation of a Dual Two-Level Inverter with Power Balancing Capability , 2006, Conference Record of the 2006 IEEE Industry Applications Conference Forty-First IAS Annual Meeting.

[18]  G. Strbac,et al.  Value of Bulk Energy Storage for Managing Wind Power Fluctuations , 2007, IEEE Transactions on Energy Conversion.

[19]  M. Baran,et al.  Improved wind farm’s power availability by battery energy storage systems: modeling and control , 2008, 2008 34th Annual Conference of IEEE Industrial Electronics.

[20]  K.A. Corzine,et al.  Overdistention operation of cascaded multilevel inverters , 2006, IEEE Transactions on Industry Applications.

[21]  D. Boroyevich,et al.  A novel SVM algorithm for multilevel three-phase converters , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[22]  Wei Li,et al.  Real-Time Simulation of a Wind Turbine Generator Coupled With a Battery Supercapacitor Energy Storage System , 2010, IEEE Transactions on Industrial Electronics.

[23]  Nikos D. Hatziargyriou,et al.  Centralized Control for Optimizing Microgrids Operation , 2008 .

[24]  G. Guidi,et al.  An Optimized Converter for Battery-Supercapacitor Interface , 2007, 2007 IEEE Power Electronics Specialists Conference.

[25]  Keith Corzine,et al.  Over-distention operation of cascaded multilevel inverters , 2003, IEEE International Electric Machines and Drives Conference, 2003. IEMDC'03..

[26]  Kwanghee Nam,et al.  Dual-inverter control strategy for high-speed operation of EV induction motors , 2004, IEEE Transactions on Industrial Electronics.

[27]  Xuan Liu,et al.  Microgrids — an integration of renewable energy technologies , 2008, 2008 China International Conference on Electricity Distribution.

[28]  Liu Wei,et al.  A modified power flow calculation method for radial distribution system , 2008, 2008 China International Conference on Electricity Distribution.

[29]  S. Teleke,et al.  STATCOM with energy storage for smoothing intermittent wind farm power , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[30]  D. Casadei,et al.  Power balancing of a multilevel converter with two insulated supplies for three-phase six-wire loads , 2005, 2005 European Conference on Power Electronics and Applications.

[31]  U. K. Madawala,et al.  Connecting two wind turbine generators to the grid using only one three level NPC inverter , 2010, IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society.

[32]  Keith Corzine,et al.  Performance characteristics of a cascaded two-level converter , 1999 .

[33]  K. Gopakumar,et al.  A dual two-level inverter scheme with common mode voltage elimination for an induction motor drive , 2004, IEEE Transactions on Power Electronics.

[34]  K. Gopakumar,et al.  PWM signal generation for dual inverter fed open-end winding induction motor drive using only the instantaneous reference phase amplitudes , 2003, The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003..

[35]  Mukhtiar Singh,et al.  Control of PMSG based variable speed wind-battery hybrid system in an isolated network , 2009, 2009 IEEE Power & Energy Society General Meeting.

[36]  P.W. Lehn,et al.  Control Methodology to Mitigate the Grid Impact of Wind Turbines , 2007, IEEE Transactions on Energy Conversion.

[37]  J. Driesen,et al.  Distributed generation: challenges and possible solutions , 2006, 2006 IEEE Power Engineering Society General Meeting.