ISFET with built-in gold electrode and readout circuit with frequency-adjustable pulse output

In this paper, an ISFET with a built-in gold reference electrode and an integrated readout circuit with frequency-adjustable pulse output is presented. The CMOS chip is based on the TSMC 0.35mm process with post-process gold metallization. The sensing membrane is surrounded with two gold rings, which can be used as a reference electrode or an enzyme-immobilizing material for pH-value or biomolecule-concentration detection. The ISFET is one of the input differential transistor pair of an operational amplifier in its readout circuit, which mainly consists of a voltage-to-current converter and a current-controlled oscillator. The output pulse frequency is linearly proportional to the effective gate voltage of the ISFET, which is immersed in the analyzed solution with a stably biasing reference electrode. A current-offset structure is added into the oscillator to shift the transfer characteristic line of the output frequency versus the effective input voltage, which usually varies due to process variation. The transfer characteristics of the pulse frequency versus pH value are measured by an external Ag/AgCl reference electrode and an on-chip gold reference electrode, respectively. The built-in gold reference electrode brings about a larger sensitivity. The measured output transfer characteristics show the sensitivity of more than 2kHz/pH with linearity of 99% at least.

[1]  P Bergveld,et al.  Development of an ion-sensitive solid-state device for neurophysiological measurements. , 1970, IEEE transactions on bio-medical engineering.

[2]  O. Sidek,et al.  ISFET pH sensor characterization: towards biosensor microchip application , 2004, 2004 IEEE Region 10 Conference TENCON 2004..

[3]  Piet Bergveld,et al.  Thirty years of ISFETOLOGY ☆: What happened in the past 30 years and what may happen in the next 30 years , 2003 .

[4]  T. Pan,et al.  Study of high-k Er2O3 thin layers as ISFET sensitive insulator surface for pH detection , 2009 .

[5]  M. Esashi,et al.  Application of catheter-tip i.s.f.e.t. for continuousin vivo measurement , 1980, Medical and Biological Engineering and Computing.

[6]  A Multisensor Readout Circuit with a Multiplexed Pulse-signal Output , 2012 .

[7]  Y. Juang,et al.  CMOS Biomedical Sensor with In Situ Gold Reference Electrode for Urine Detection Application , 2012 .

[8]  Ying-Zong Juang,et al.  Multiple type biosensors fabricated using the CMOS BioMEMS platform , 2010 .

[9]  Sang Kyu Kim,et al.  Ion-Sensitive Field-Effect Transistor for Biological Sensing , 2009, Sensors.

[10]  J. V. Spiegel,et al.  The extended gate chemically sensitive field effect transistor as multi-species microprobe☆ , 1983 .

[11]  C. Toumazou,et al.  High gain ISFET based νMOS chemical inverter , 2012 .

[12]  Sinclair S. Yee,et al.  Miniature liquid junction reference electrode with micromachined silicon cavity , 1988 .

[13]  I-Yu Huang,et al.  Improvement of integrated Ag/AgCl thin-film electrodes by KCl-gel coating for ISFET applications , 2003 .