Harmonic domain modelling of direct connected generator and HVDC convertor units.

This thesis describes a new method of analysing the harmonic content of direct connected generator-HVdc convertor units. Existing analysis techniques are reviewed, and their strengths and weaknesses are discussed. A set of simultaneous equations that fully describes the harmonic interaction among the generators, convertors and the dc system is derived. The simultaneous equations are solved using Newton's method. By exploiting the sparse nature of the Jacobian matrix of partial derivatives, the solution is obtained quickly. The solution of a test system is verified by means of dynamic simulations. The developed unified solution is a significant improvement on existing harmonic analysis. A harmonic model of the salient-pole generator is developed and validated against time domain simulations and harmonic measurement results obtained from the Benmore convertor station when being operated as a group connected unit. The relationship between the generator terminal voltages and currents in the presence of saliency can be represented by analytical expressions in sequence components, derived from normal machine parameters. The effect of generator saturation on the harmonic content is not significant. The effect of rotor angle on the commutation process in the presence of saliency is significant in direct connected units. By choosing the generator terminal voltage as the firing angle reference, existing firing control for conventional HV dc schemes can be used for direct connected units with practically no modification. Provided that the nominal firing angles are kept within the restriction limits, imposed by the overlap angle, generator terminal power factor, equivalent continuous negative-sequence harmonic loading and the number of generators, practically no extra capacity for harmonic current loading is required in direct connected units. The generator harmonic ratings can be taken at the nominal speed and rated power output. Conventional tuned dc filters are ineffective in adjustable speed operation. Finally, detailed three-phase harmonic information of the Benmore convertor station when being operated in the group connected mode is collected and discussed. The test results are used for validating the developed models, and they also provide valuable evidence of the feasibility of direct connected units.

[1]  G. Asplund,et al.  Active DC filter for HVDC system-a test installation in the Konti-Skan DC link at Lindome converter station , 1993 .

[2]  Alan R. Wood,et al.  HVDC converter transformer core saturation instability: a frequency domain analysis , 1996 .

[3]  S. Crary Two-Reaction Theory of Synchronous Machines , 1937, Transactions of the American Institute of Electrical Engineers.

[4]  Robert D. Laramore,et al.  An Introduction to Electrical Machines and Transformers , 1981 .

[5]  William H. Press,et al.  Numerical Recipes in Fortran 77 , 1992 .

[6]  Neville R. Watson,et al.  Steady state model of the AC/DC convertor in the harmonic domain , 1995 .

[7]  M. Villablanca,et al.  Harmonic elimination by DC ripple reinjection in generator-convertor units operating at variable speeds , 1993 .

[8]  J. Arrillaga,et al.  Newton-type algorithms for the harmonic phasor analysis of nonlinear power circuits in periodical steady state with special reference to magnetic nonlinearities , 1988 .

[9]  M. V. C. Lisboa,et al.  THREE-PHASE THREE-LIMB TRANSFORMER MODELS IN THE HARMONIC DOMAIN , 1996 .

[10]  Narain G. Hingorani,et al.  High-voltage DC transmission: a power electronics workhorse , 1996 .

[11]  Neville R. Watson,et al.  Comparison of steady-state and dynamic models for the calculation of AC/DC system harmonics , 1987 .

[12]  R. Yacamini,et al.  Harmonics in multiple convertor systems: a generalised approach , 1980 .

[13]  A. M. Gole,et al.  Digital Simulation of DC Links and AC Machines , 1983, IEEE Transactions on Power Apparatus and Systems.

[14]  C. H. Lee Saturation Harmonics of Polyphase Induction Machines , 1961, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[15]  J. G. Mayordomo,et al.  Harmonic power flow for unbalanced systems , 1993 .

[16]  E. V. Larsen,et al.  Low-order harmonic interactions on AC/DC systems , 1989 .

[17]  C. A. Nickle,et al.  Synchronous machines I — An extension of Blondel's two-reaction theory , 1926, Journal of the A.I.E.E..

[18]  R. M. Mathur,et al.  Evaluation of Unit Connected, Variable Speed, Hydropower Station for HVDC Power Transmission , 1989, IEEE Power Engineering Review.

[19]  Neville R. Watson,et al.  Newton solution for the steady-state interaction of AC/DC systems , 1996 .

[20]  R. G. Harley,et al.  Comparative study of saturation methods in synchronous machine models , 1980 .

[21]  R. Yacamini,et al.  Comprehensive calculation of convertor harmonics with system impedances and control representation , 1986 .

[22]  Jose R. Marti,et al.  A synchronous machine model for three-phase harmonic analysis and EMTP initialization , 1991 .

[23]  Z. Zlatev Computational Methods for General Sparse Matrices , 1991 .

[24]  H. H. Hwang Unbalanced Operations of Three-Phase Machines with Damper Circuits , 1969 .

[25]  Alan R. Wood,et al.  HVDC convertor waveform distortion: a frequency-domain analysis , 1995 .

[26]  S. Sankar,et al.  Dynamic simulation of ac/dc systems with reference to convertor control and unit connection , 1991 .

[27]  Jos Arrillaga,et al.  Analysis of the harmonic distortion resulting from the interaction between synchronous machines and HVDC convertors , 1988 .

[28]  J. Arrillaga,et al.  Analysis of transformer-generator interaction in the harmonic domain , 1994 .

[29]  Hermann W. Dommel,et al.  Digital Computer Solution of Electromagnetic Transients in Single-and Multiphase Networks , 1969 .

[30]  Wilsun Xu,et al.  A three-phase converter model for harmonic analysis of HVDC systems , 1994 .

[31]  R. D. Ball,et al.  Alternating-current machines. A review of progress , 1962 .

[32]  Erich Uhlmann,et al.  Power transmission by direct current , 1975 .

[33]  K. N. Mortensen,et al.  Feasibility Study of AC- and DC-side Active Filters for HVDC Converter Terminals , 1989, IEEE Power Engineering Review.

[34]  J. F. Eggleston Harmonic modelling of transmission systems containing synchronous machines and static convertors , 1985 .

[35]  José Roberto Camacho,et al.  Operating characteristics of unit and group connected generator-HVDC converter schemes , 1993 .

[36]  W. Enright,et al.  Harmonic measurements from a group connected generator HVDC converter scheme , 1995 .