The ICARUS Front-end Preamplifier Working at Liquid Argon Temperature

We describe characteristics and performance of the low-noise front-end preamplifier used in the ICARUS 50-litre liquid Argon Time Projection Chamber installed in the CERN West Area Neutrino Facility during the 1997-98 neutrino runs. The preamplifiers were designed to work immersed in ultra-pure liquid Argon at a temperature of 87 K. The successful operation of the ICARUS T600 detector at LNGS (1) and the recent growing interest in the potentiality of the LAr-TPC as multi-kton detector for neutrino physics and rare events search, have triggered additional R&D studies to further improve the detector performance with respect to the presently available technologies. In particular the use of low noise front-end electronics working immersed in liquid Argon is under discussion and test in several laboratories. In the present note, a description is given of the solution developed in the late nineties within the ICARUS collaboration, and successfully operated for several years in a 50-litre LAr-TPC. The pre-amplifier design and its performance are discussed in detail.

[1]  P. Tyagi Multilayer Edge Molecular Devices Based on Plasma Oxidation of Photolithographically Defined Bottom Metal Electrode , 2011, 1111.5087.

[2]  A. Dabrowska,et al.  Underground operation of the ICARUS T600 LAr-TPC: first results , 2011, 1106.0975.

[3]  D. Cavalli,et al.  Performance of a liquid argon time projection chamber exposed to the CERN West Area Neutrino Facility neutrino beam , 2006 .

[4]  S. Amerio,et al.  Design, construction and tests of the ICARUS T600 detector , 2004 .

[5]  M. Campanelli,et al.  First observation of 140-cm drift ionizing tracks in the ICARUS liquid-argon TPC , 2000 .

[6]  C. Cerri The front-end electronics of the NA48 liquid krypton calorimeter , 1998 .

[7]  P. Cennini,et al.  LOW-NOISE BICMOS FRONT-END AND FAST ANALOGUE MULTIPLEXER FOR IONIZATION CHAMBER , 1998 .

[8]  A. I. Kalinin,et al.  Performance of an electromagnetic liquid krypton calorimeter based on a ribbon electrode tower structure , 1996 .

[9]  Sandro Centro,et al.  A hybrid charge sensitive amplifier for high capacitance detectors , 1988 .

[10]  Antonio Francesco Longoni,et al.  Design of a charge sensitive preamplifier on high resistivity silicon , 1988 .

[11]  R. Kirschman,et al.  Cold electronics: An overview , 1984 .

[12]  E. Kendall,et al.  Design considerations for improving low-temperature noise performance of silicon JFET's , 1975 .

[13]  B. Lengeler,et al.  Semiconductor devices suitable for use in cryogenic environments , 1974 .

[14]  D. Cavalli,et al.  The ICARUS 50-l LAr TPC in the CERN neutrino beam , 1998 .

[15]  A. V. Der Ziel,et al.  Thermal Noise in Field-Effect Transistors , 1962, Proceedings of the IRE.