Random Segmentation Based Principal Component Analysis to Remove Residual MR Gradient Artifact in the Simultaneous EEG/fMRI: A Preliminary Study

In the electroencephalography (EEG) data simultaneously acquired with the functional magnetic resonance imaging (fMRI) data, the removal of the residual magnetic resonance (MR) gradient artifacts has been a challenging issue. To remove gradient artifacts generated from switching MR gradient field, average artifact subtraction (AAS) has been widely used. After applying the AAS method, however, residual MR gradient artifacts still remained in corrected EEG data. In this study, we proposed a novel method to remove the residual MR gradient artifacts (GAs) using random segmentation based principal component analysis (rsPCA). The performance of rsPCA was compared to that of the independent component analysis (ICA) method using data acquired from a motor imagery task. The results indicated that rsPCA could suppress further the residual MR gradient artifacts remained from the AAS step compared to the ICA method.

[1]  David Poeppel,et al.  How can EEG/MEG and fMRI/PET data be combined? , 2002, Human brain mapping.

[2]  Rami K. Niazy,et al.  Removal of FMRI environment artifacts from EEG data using optimal basis sets , 2005, NeuroImage.

[3]  L Bozzao,et al.  Real-time MR artifacts filtering during continuous EEG/fMRI acquisition. , 2003, Magnetic resonance imaging.

[4]  Jeff H. Duyn,et al.  Statistical feature extraction for artifact removal from concurrent fMRI-EEG recordings , 2012, NeuroImage.

[5]  Gian Luca Romani,et al.  Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis , 2007, NeuroImage.

[6]  S. Debener,et al.  Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[7]  Louis Lemieux,et al.  Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its Subtraction , 1998, NeuroImage.

[8]  J. C. de Munck,et al.  Artifact removal in co-registered EEG/fMRI by selective average subtraction , 2007, Clinical Neurophysiology.

[9]  Jong-Hwan Lee,et al.  Application of Independent Component Analysis for the Data Mining of Simultaneous Eeg–fMRI: Preliminary Experience on Sleep Onset , 2009, The International journal of neuroscience.

[10]  Michiro Negishi,et al.  Removal of time-varying gradient artifacts from EEG data acquired during continuous fMRI , 2004, Clinical Neurophysiology.

[11]  Robert Turner,et al.  A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI , 2000, NeuroImage.