Thermodynamic analysis of a low-pressure economizer based waste heat recovery system for a coal-fired power plant

An LPE (low-pressure economizer) based waste heat recovery system for a CFPP (coal-fired power plant) is investigated thermodynamically. With the installation of LPE in the flue before the FGD (flue gas desulfurizer), the heat contained in the exhaust flue gas can be recovered effectively and the water consumption can be reduced in the FGD resulted from the temperature dropped flue gas. The impacts on the related apparatuses after installing LPE in a CFPP are analyzed and the internal relationships among correlated parameters are presented. The efficiencies of LPE installed in a CFPP evaluated by the first law, the second law and the thermal equilibrium efficiencies are also compared and analyzed. A detailed case study based on a 350 MW CFPP unit is presented and the variations of the thermal performance after the installation of LPE are investigated. The results show that the second law and the thermal equilibrium efficiencies are increased which can be indicators to evaluate the performance of the LPE system while the first law efficiency is decreased after installing LPE. Results also show that the saving of SCE (standard coal equivalent) is 3.85 g/(kW·h) for this CFPP unit under full load after installing LPE.

[1]  Jiangfeng Wang,et al.  Parametric optimization and comparative study of organic Rankine cycle (ORC) for low grade waste heat recovery , 2009 .

[2]  George Papadakis,et al.  Low­grade heat conversion into power using organic Rankine cycles - A review of various applications , 2011 .

[3]  James Kennedy,et al.  Particle swarm optimization , 2002, Proceedings of ICNN'95 - International Conference on Neural Networks.

[4]  Henryk Łukowicz,et al.  Analysis of the use of waste heat obtained from coal-fired units in Organic Rankine Cycles and for brown coal drying , 2012 .

[5]  Ying Wu,et al.  Application of a low pressure economizer for waste heat recovery from the exhaust flue gas in a 600 MW power plant , 2012 .

[6]  S. K. Tyagi,et al.  nergy and exergy analyses of thermal power plants : A review , 2011 .

[7]  Shi Yue-tao ENERGY-SAVING EFFECT OF ADDITIONALLY INSTALLED LOW-PRESSURE ECONOMIZER IN THERMODYNAMIC SYSTEM OF THERMAL POWER PLANT , 2008 .

[8]  Jie Ji,et al.  Energetic and exergetic investigation of an organic Rankine cycle at different heat source temperatures , 2012 .

[9]  Y. Çengel,et al.  Thermodynamics : An Engineering Approach , 1989 .

[10]  K. Goni Boulama,et al.  Power generation from residual industrial heat , 2010 .

[11]  Haotian Wei Achieving Water-saving Purpose by Reducing Inlet-gas Temperatures in Wet Flue Gas Desulfurization Process , 2010 .

[12]  J. Van Roy,et al.  Parametric optimization and performance analysis of a waste heat recovery system using Organic Ranki , 2010 .

[13]  Chi-Chuan Wang,et al.  Effect of working fluids on organic Rankine cycle for waste heat recovery , 2004 .

[14]  Yang Nan Economic Analysis of Installing Low Pressure Economizer in Thermal Power Plant , 2006 .

[15]  Farid Chejne,et al.  A technical, economical and market review of organic Rankine cycles for the conversion of low-grade heat for power generation , 2012 .

[16]  Huang Xin-yuan Economic Analysis and Thermodynamic System Optimization of Front-located Air Preheater With Liquid Mediator , 2011 .

[17]  Chen Changhe Combination Utilization of Air Preheater with Low-Pressure Economizer in MSW Incineration Power Plants , 2006 .