Analysis of geometrical distortion and statistical variance in length, area, and volume in a linearly scanned 3-D ultrasound image

A linearly scanned three-dimensional (3-D) ultrasound imaging system is considered. The transducer array is initially oriented along the x axis and aimed in the y direction. After being tilted by an angle /spl theta/ about the x axis, and then swiveled by an angle /spl phi/ about the y axis, it is translated in the z direction, in steps of size d, to acquire a series of parallel two-dimensional (2-D) images. From these, the 3-D image is reconstructed, using the nominal values of the parameters (/spl phi/, /spl theta/, d). Thus, any systematic or random errors in these, relative to their actual values (/spl phi//sub 0/, /spl theta//sub 0/, d/sub 0/), will respectively cause distortions or variances in length, area, and volume in the reconstructed 3-D image, relative to the 3-D object. Here, the authors analyze these effects. Compact linear approximations are derived for the relative distortions as functions of the parameter errors, and hence, for the relative variances as functions of the parameter variances. Also, exact matrix formulas for the relative distortions are derived for arbitrary values of (/spl phi/, /spl theta/, d) and (/spl phi//sub 0/, /spl theta//sub 0/, d/sub 0/). These were numerically compared to the linear approximations and to measurements from simulated 3-D images of a cubical object and real 3-D images of a wire phantom. In every case tested, the theory was confirmed within experimental error (0.5%).

[1]  S. Tong,et al.  Analysis of linear, area and volume distortion in 3D ultrasound imaging. , 1998, Ultrasound in medicine & biology.

[2]  J. Seward,et al.  Three- and four-dimensional cardiovascular ultrasound imaging: a new era for echocardiography. , 1993, Mayo Clinic proceedings.

[3]  D. Downey,et al.  Three-dimensional sonographic reconstruction: techniques and diagnostic applications. , 1993, AJR. American journal of roentgenology.

[4]  T R Nelson,et al.  Three-dimensional ultrasound in obstetrics and gynecology. , 2001, Radiologic clinics of North America.

[5]  E O Ofili,et al.  Three-dimensional and four-dimensional echocardiography. , 1994, Ultrasound in medicine & biology.

[6]  A Fenster,et al.  Three-dimensional colour Doppler imaging. , 1993, Ultrasound in medicine & biology.

[7]  T. Nelson,et al.  Three-dimensional ultrasound imaging. , 1998, Ultrasound in medicine & biology.

[8]  S. Tong,et al.  A three-dimensional ultrasound prostate imaging system. , 1996, Ultrasound in medicine & biology.

[9]  R W Prager,et al.  Rapid calibration for 3-D freehand ultrasound. , 1998, Ultrasound in medicine & biology.

[10]  Davor Jurkovic,et al.  Three-dimensional ultrasound in obstetrics and gynecology , 1997 .

[11]  T. Nelson,et al.  Three‐dimensional ultrasound , 1999, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[12]  A. Fenster,et al.  3-D ultrasound imaging: a review , 1996 .