Uncertainty propagation in calibration of parallel kinematic machines

Abstract This paper outlines in detail a method for determining the uncertainty present in the kinematic parameters (joint locations, initial strut lengths, and spindle location and orientation) for parallel kinematic devices after calibration. The uncertainty estimation method using Monte Carlo simulations was applied to a sequential method for determining the kinematic parameters of fully assembled Hexel Tornado 2000 (a 6–3 Stewart platform) milling machine. Results for the uncertainty present in the kinematic parameters of a Hexel Tornado 2000 milling machine after calibration using a SMX 4,000 laser tracker are shown.

[1]  Tatsuo Arai,et al.  Accuracy analysis of a modified Stewart platform manipulator , 1995, Proceedings of 1995 IEEE International Conference on Robotics and Automation.

[2]  Hanqi Zhuang,et al.  Method for kinematic calibration of stewart platforms , 1993, J. Field Robotics.

[3]  Johannes A. Soons Measuring the Geometric Errors of a Hexapod Machine Tool | NIST , 1999 .

[4]  Hanqi Zhuang,et al.  Modeling Gimbal Axis Misalignments and Mirror Center Offset in a Single-Beam Laser Tracking Measurement System , 1995, Int. J. Robotics Res..

[5]  Hanqi Zhuang,et al.  Self-calibration and mirror center offset elimination of a multi-beam laser tracking system , 1992, Robotics Auton. Syst..

[6]  J. A. Soons,et al.  Error Analysis Of A Hexapod Machine Tool , 1970 .

[7]  Jian Wang,et al.  On the accuracy of a Stewart platform. II. Kinematic calibration and compensation , 1993, [1993] Proceedings IEEE International Conference on Robotics and Automation.

[8]  Lixin Liu,et al.  Self-calibration of a class of parallel manipulators , 1996, Proceedings of IEEE International Conference on Robotics and Automation.