Thermal comfort analysis of a low temperature waste energy recovery system: SIECHP

The use of a recovery device is justified in terms of energy savings and environmental concerns. But it is clear that the use of a recovery system also has to lead to controlling indoor environmental quality, nowadays a priority concern. In this article, experimental research has been carried out whose aim is to study the thermal comfort provided by a combined recovery equipment (SIECHP), consisting of a ceramic semi-indirect evaporative cooler (SIEC) and a heat pipe device (HP) to recover energy at low temperature in air-conditioning systems. To characterize this device empirically in terms of thermal comfort (TC), Fanger's predicted mean vote (PMV), draught rate, and vertical air temperature difference were used in this study as the TC criteria.

[1]  Y. Jannot,et al.  Un procédé économique pour l'amélioration du confort thermique en zone tropicale séche: la ventilation forcée par de l'air extérieur éventuellement humidifiéAmelioration of thermal comfort in dry tropical climate by use of an economic process: direct evaporative cooling , 1994 .

[2]  Saffa Riffat,et al.  Mathematical model of indirect evaporative cooler using porous ceramic and heat pipe , 2004 .

[3]  J. Watt,et al.  Evaporative Air Conditioning Handbook , 1986 .

[4]  Krishan Kant,et al.  Space conditioning using evaporative cooling for summers in Delhi , 2001 .

[5]  S. C. Kaushik,et al.  Evaluation of liquid dessicant based evaporative cooling cycles for typical hot and humid climates , 1994 .

[6]  Ghazi Al-Otaibi,et al.  The potential of the evaporative cooling techniques in the Gulf Region of the Kingdom of Saudi Arabia , 1993 .

[7]  P. Fanger,et al.  Extension of the PMV model to non-air-conditioned buildings in warm climates , 2002 .

[8]  S. Chirarattananon,et al.  Application of radiant cooling as a passive cooling option in hot humid climate , 2007 .

[9]  H. Arkin,et al.  Feasibility of direct-indirect evaporative cooling for residences, based on studies with a desert cooler , 1994 .

[10]  Krishan Kant,et al.  Thermal comfort in a room with exposed roof using evaporative cooling in Delhi , 2003 .

[11]  V. Kishore,et al.  Design and operating characteristics of evaporative cooling systems , 1987 .

[12]  Ali A. Badran,et al.  Performance of cool towers under various climates in Jordan , 2003 .

[13]  Kwang-Chul Noh,et al.  Thermal comfort and indoor air quality in the lecture room with 4-way cassette air-conditioner and mixing ventilation system , 2007 .

[14]  Zahra Ghiabaklou,et al.  Thermal comfort prediction for a new passive cooling system , 2003 .

[15]  José M. Corberán,et al.  ‘ART’ A Computer Code To Assist The Design Of Refrigeration and A/C Equipment , 2002 .

[16]  P. Fanger,et al.  Air turbulence and sensation of draught , 1988 .

[17]  S. C. Kaushik,et al.  Evaluation of solid-desiccant-based evaporative cooling cycles for typical hot and humid climates , 1995 .

[18]  Ahmed Hamza H. Ali,et al.  Passive cooling of water at night in uninsulated open tank in hot arid areas , 2007 .

[19]  Mehdi N. Bahadori,et al.  Viability of wind towers in achieving summer comfort in the hot arid regions of the middle east , 1994 .

[20]  Drew W. Johnson,et al.  Analysis of heat and mass transfer phenomena in hollow fiber membranes used for evaporative cooling , 2003 .

[21]  M. Kaviany Principles of heat transfer in porous media , 1991 .

[22]  J. R. Camargo,et al.  Experimental performance of a direct evaporative cooler operating during summer in a Brazilian city , 2005 .

[23]  Saffa Riffat,et al.  Performance of porous ceramic evaporators for building cooling application , 2003 .

[24]  Javier F. Urchueguía,et al.  SIMULATION OF AN AIR-TO-WATER REVERSIBLE HEAT PUMP , 2000 .

[25]  S. Chirarattananon,et al.  An experimental investigation of application of radiant cooling in hot humid climate , 2006 .

[26]  N. Nahar,et al.  Studies on solar passive cooling techniques for arid areas , 1999 .