Improved k-t PCA Algorithm Using Artificial Sparsity in Dynamic MRI

The k-t principal component analysis (k-t PCA) is an effective approach for high spatiotemporal resolution dynamic magnetic resonance (MR) imaging. However, it suffers from larger residual aliasing artifacts and noise amplification when the reduction factor goes higher. To further enhance the performance of this technique, we propose a new method called sparse k-t PCA that combines the k-t PCA algorithm with an artificial sparsity constraint. It is a self-calibrated procedure that is based on the traditional k-t PCA method by further eliminating the reconstruction error derived from complex subtraction of the sampled k-t space from the original reconstructed k-t space. The proposed method is tested through both simulations and in vivo datasets with different reduction factors. Compared to the standard k-t PCA algorithm, the sparse k-t PCA can improve the normalized root-mean-square error performance and the accuracy of temporal resolution. It is thus useful for rapid dynamic MR imaging.

[1]  F H Epstein,et al.  Adaptive sensitivity encoding incorporating temporal filtering (TSENSE) † , 2001, Magnetic resonance in medicine.

[2]  Peter Boesiger,et al.  k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations , 2003, Magnetic resonance in medicine.

[3]  Feng Huang,et al.  Improved partial k-space reconstruction technique for dynamic myocardial perfusion MRI , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[4]  Feng Huang,et al.  k‐t GRAPPA: A k‐space implementation for dynamic MRI with high reduction factor , 2005, Magnetic resonance in medicine.

[5]  Peter Kellman,et al.  Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA) , 2005, Magnetic resonance in medicine.

[6]  S. Kanao,et al.  Cardiac functional analysis by free-breath real-time cine CMR with a spatiotemporal filtering method, TSENSE: comparison with breath-hold cine CMR. , 2006, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[7]  P. Kellman,et al.  Dynamic parallel MRI by generating sparse data : tracking temporal changes , 2006 .

[8]  Zhi-Pei Liang,et al.  Spatiotemporal Imaging with Partially Separable Functions , 2007, 2007 Joint Meeting of the 6th International Symposium on Noninvasive Functional Source Imaging of the Brain and Heart and the International Conference on Functional Biomedical Imaging.

[9]  A. Kronfeld,et al.  Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal filtering (TSENSE) , 2007, Journal of magnetic resonance imaging : JMRI.

[10]  P. Kellman,et al.  A Sparse TSENSE approach for improved dynamic parallel MRI , 2007 .

[11]  F. Huang,et al.  High‐pass GRAPPA: An image support reduction technique for improved partially parallel imaging , 2008, Magnetic resonance in medicine.

[12]  D. Sodickson,et al.  Comprehensive quantification of signal‐to‐noise ratio and g‐factor for image‐based and k‐space‐based parallel imaging reconstructions , 2008, Magnetic resonance in medicine.

[13]  P. Boesiger,et al.  Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE , 2008, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[14]  John M. Pauly,et al.  Improved Time Series Reconstruction for Dynamic Magnetic Resonance Imaging , 2009, IEEE Transactions on Medical Imaging.

[15]  Kay Nehrke,et al.  k‐t PCA: Temporally constrained k‐t BLAST reconstruction using principal component analysis , 2009, Magnetic resonance in medicine.

[16]  S. Vasanawala,et al.  kt SPIRiT for Ultra-Fast Cardiac Cine Imaging with Prospective or Retrospective Cardiac Gating , 2009 .

[17]  John J Sheehan,et al.  Highly accelerated contrast‐enhanced MR angiography: Improved reconstruction accuracy and reduced noise amplification with complex subtraction , 2010, Magnetic resonance in medicine.

[18]  E. Nagel,et al.  3D myocardial perfusion-CMR using a multi-transmit coil and k-t PCA reconstruction to detect flow limiting coronary stenosis , 2011, Journal of Cardiovascular Magnetic Resonance.

[19]  P. Boesiger,et al.  High resolution three‐dimensional cardiac perfusion imaging using compartment‐based k‐t principal component analysis , 2011, Magnetic resonance in medicine.

[20]  Sen Jia,et al.  On analysis of k-t BLAST for dynamic MRI , 2011, 2011 9th IEEE International Conference on Control and Automation (ICCA).

[21]  Daniel K Sodickson,et al.  Exploiting sparsity to accelerate noncontrast MR angiography in the context of parallel imaging , 2012, Magnetic resonance in medicine.

[22]  Sebastian Kozerke,et al.  MRI temporal acceleration techniques , 2012, Journal of magnetic resonance imaging : JMRI.

[23]  M. Reiser,et al.  High-resolution cine MRI with TGRAPPA for fast assessment of left ventricular function at 3 Tesla. , 2013, European journal of radiology.

[24]  M. Markl,et al.  K‐t GRAPPA accelerated phase contrast MRI: Improved assessment of blood flow and 3‐directional myocardial motion during breath‐hold , 2013, Journal of magnetic resonance imaging : JMRI.

[25]  D. Maintz,et al.  The use of k-t PCA accelerated dual-venc 3D flow MRI to assess hemodynamics before and after flow diverting stent implantation in cerebral aneurysm models , 2014, Journal of Cardiovascular Magnetic Resonance.

[26]  W. Segars,et al.  MRXCAT: Realistic numerical phantoms for cardiovascular magnetic resonance , 2014, Journal of Cardiovascular Magnetic Resonance.

[27]  Ling Xia,et al.  An improved non‐Cartesian partially parallel imaging by exploiting artificial sparsity , 2017, Magnetic resonance in medicine.