Handheld line-field confocal optical coherence tomography for dermatology

The use of non-invasive imaging techniques in dermatology has been reported to improve the diagnostic accuracy and the practice of biopsies, and at the same time to reduce the need for tissue excision. However, the current clinically-available imaging techniques do not yet entirely meet the need for early and accurate, non-invasive detection of all skin cancers. A handheld line-field confocal optical coherence tomography (LC-OCT) device has been designed for high-resolution non-invasive imaging of human skin, in vivo. LC-OCT delivers tomographic images in real-time (10 frames/s) with a quasi isotropic spatial resolution of ~ 1 μm, revealing a comprehensive morphological mapping of skin tissues at a cellular level, down to a depth of ~500 μm. The device has been applied to the in vivo imaging of various skin lesions. Surgical excisions of the lesions have then been performed followed by tissue processing to realize H&E-stained histopathological images. The spatial resolution, orientation, and imaging contrast mechanism of the LC-OCT images have allowed for a good level of similarity with the conventional histopathological images. LC-OCT was able to show most of the histopathological elements that allow for medical diagnosis. Using handheld LC-OCT as an adjunct tool in dermatology could help improve clinical diagnostic accuracy, allowing for the early detection of malignant skin tumors and a reduction in the number of surgical excisions of benign lesions.

[1]  Michael McCarthy US melanoma prevalence has doubled over past 30 years , 2015, BMJ : British Medical Journal.

[2]  Elizabeth Lazaridou,et al.  Epidemiological trends in skin cancer , 2017, Dermatology practical & conceptual.

[3]  C K Hitzenberger,et al.  Dynamic focus in optical coherence tomography for retinal imaging. , 2006, Journal of biomedical optics.

[4]  Arthur J. Davis,et al.  Simultaneous dual-band line-field confocal optical coherence tomography: application to skin imaging. , 2019, Biomedical optics express.

[5]  J. Welzel Optical coherence tomography in dermatology: a review , 2001, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[6]  Iris Riemann,et al.  High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution. , 2003, Journal of biomedical optics.

[7]  Arthur J. Davis,et al.  Line-field confocal time-domain optical coherence tomography with dynamic focusing. , 2018, Optics express.

[8]  R. Hofmann-Wellenhof,et al.  Impact of in vivo reflectance confocal microscopy on the number needed to treat melanoma in doubtful lesions , 2014 .

[9]  A. Coleman,et al.  Histological correlates of optical coherence tomography in non‐melanoma skin cancer , 2013, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[10]  C. Longo,et al.  In vivo confocal microscopy for diagnosis of melanoma and basal cell carcinoma using a two-step method: analysis of 710 consecutive clinically equivocal cases. , 2012, The Journal of investigative dermatology.

[11]  Georgios N Stamatas,et al.  Optical non-invasive approaches to diagnosis of skin diseases. , 2002, The journal of investigative dermatology. Symposium proceedings.

[12]  C. Longo,et al.  The impact of in vivo reflectance confocal microscopy on the diagnostic accuracy of lentigo maligna and equivocal pigmented and nonpigmented macules of the face. , 2010, The Journal of investigative dermatology.

[13]  C. Berking,et al.  The sensitivity and specificity of optical coherence tomography for the assisted diagnosis of nonpigmented basal cell carcinoma: an observational study , 2015, The British journal of dermatology.

[14]  S. Feldman,et al.  Incidence Estimate of Nonmelanoma Skin Cancer (Keratinocyte Carcinomas) in the U.S. Population, 2012. , 2015, JAMA dermatology.

[15]  H. Haenssle,et al.  Non‐invasive tools for the diagnosis of cutaneous melanoma , 2017, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[16]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[17]  Josep Malvehy,et al.  Skin lesion imaging with line-field confocal optical coherence tomography , 2019, BiOS.

[18]  W. Webb,et al.  Nonlinear magic: multiphoton microscopy in the biosciences , 2003, Nature Biotechnology.

[19]  E. Cinotti,et al.  In Vivo Reflectance Confocal Microscopy to Optimize the Spaghetti Technique for Defining Surgical Margins of Lentigo Maligna , 2014, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[20]  S. Florell,et al.  Digital Dermoscopic Monitoring of Atypical Nevi in Patients at Risk for Melanoma , 2007, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[21]  David A. Jackson,et al.  Three dimensional OCT images from retina and skin. , 2000, Optics express.

[22]  E. Tkaczyk,et al.  Innovations and Developments in Dermatologic Non-invasive Optical Imaging and Potential Clinical Applications , 2017, Acta dermato-venereologica.

[23]  J. Fujimoto,et al.  In vivo ultrahigh-resolution optical coherence tomography. , 1999, Optics letters.

[24]  H. Kittler,et al.  Diagnostic accuracy of dermoscopy. , 2002, The Lancet. Oncology.

[25]  Xingde Li,et al.  Continuous focus tracking for real-time optical coherence tomography. , 2005, Optics letters.

[26]  Joseph M. Schmitt,et al.  An optical coherence microscope with enhanced resolving power , 1997 .

[27]  Karsten König,et al.  Sensitivity and specificity of multiphoton laser tomography for in vivo and ex vivo diagnosis of malignant melanoma. , 2009, The Journal of investigative dermatology.

[28]  A. Jemal,et al.  Cancer statistics, 2019 , 2019, CA: a cancer journal for clinicians.

[29]  Amanda Levine,et al.  Optical Coherence Tomography in the Diagnosis of Skin Cancer. , 2017, Dermatologic clinics.

[30]  W. Drexler,et al.  Line-field parallel swept source MHz OCT for structural and functional retinal imaging. , 2015, Biomedical optics express.

[31]  V. del Marmol,et al.  Imaging of basal cell carcinoma by high‐definition optical coherence tomography: histomorphological correlation. A pilot study , 2012, The British journal of dermatology.

[32]  Steven F. Morris,et al.  The Diagnostic Accuracy of in vivo Confocal Scanning Laser Microscopy Compared to Dermoscopy of Benign and Malignant Melanocytic Lesions: A Prospective Study , 2007, Dermatology.

[33]  Jean-Luc Perrot,et al.  Line-field confocal optical coherence tomography for high-resolution noninvasive imaging of skin tumors , 2018, Journal of biomedical optics.

[34]  C. Longo,et al.  The impact of in vivo reflectance confocal microscopy for the diagnostic accuracy of melanoma and equivocal melanocytic lesions. , 2007, The Journal of investigative dermatology.

[35]  Jean-Luc Perrot,et al.  Line-field confocal optical coherence tomography , 2019, BiOS.

[36]  Rainer Hofmann-Wellenhof,et al.  Dermoscopy in the era of dermato-oncology: from bed to bench side and retour , 2016, Expert review of anticancer therapy.

[37]  S. Leon-Saval,et al.  Supercontinuum generation system for optical coherence tomography based on tapered photonic crystal fibre. , 2006, Optics express.

[38]  D. Rigel,et al.  Clinical Diagnosis of Skin Cancer: Enhancing Inspection and Early Recognition. , 2017, Dermatologic clinics.

[39]  A Rollins,et al.  In vivo video rate optical coherence tomography. , 1998, Optics express.