Design and Evaluation of the AIRGAIT Exoskeleton: Leg Orthosis Control for Assistive Gait Rehabilitation

This paper introduces the body weight support gait training system known as the AIRGAIT exoskeleton and delves into the design and evaluation of its leg orthosis control algorithm. The implementation of the mono- and biarticular pneumatic muscle actuators (PMAs) as the actuation system was initiated to generate more power and precisely control the leg orthosis. This research proposes a simple paradigm for controlling the mono- and bi-articular actuator movements cocontractively by introducing a cocontraction model. Three tests were performed. The first test involved control of the orthosis with monoarticular actuators alone without a subject (WO/S); the second involved control of the orthosis with mono- and bi-articular actuators tested WO/S; and the third test involved control of the orthosis with mono- and bi-articular actuators tested with a subject (W/S). Full body weight support (BWS) was implemented in this study during the test W/S as the load supported by the orthosis was at its maximum capacity. This assessment will optimize the control system strategy so that the system operates to its full capacity. The results revealed that the proposed control strategy was able to co-contractively actuate the mono- and bi-articular actuators simultaneously and increase stiffness at both hip and knee joints.

[1]  Yoichi Hori,et al.  Experimental verification of infinity norm approach for force maximization of manipulators driven by bi-articular actuators , 2011, Proceedings of the 2011 American Control Conference.

[2]  Noboru Momose,et al.  Development of robot leg which provided with the bi-articular actuator for training techniques of rehabilitation , 2009, RO-MAN 2009 - The 18th IEEE International Symposium on Robot and Human Interactive Communication.

[3]  R. Riener,et al.  A Novel Method for Automatic Treadmill Speed Adaptation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[4]  KyoungKwan Ahn,et al.  Improvement of the control performance of pneumatic artificial muscle manipulators using an intelligent switching control method , 2004 .

[5]  Jiping He,et al.  Characterization of the Dynamic Properties of Pneumatic Muscle Actuators , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[6]  Masayoshi Tomizuka,et al.  A gait rehabilitation strategy inspired by an iterative learning algorithm , 2012 .

[7]  Manfred Morari,et al.  Automatic gait-pattern adaptation algorithms for rehabilitation with a 4-DOF robotic orthosis , 2004, IEEE Transactions on Robotics and Automation.

[8]  A. Taherifar,et al.  LOKOIRAN- A novel robot for rehabilitation of spinal cord injury and stroke patients , 2013, 2013 First RSI/ISM International Conference on Robotics and Mechatronics (ICRoM).

[9]  S. K. Banala,et al.  Novel Gait Adaptation and Neuromotor Training Results Using an Active Leg Exoskeleton , 2010, IEEE/ASME Transactions on Mechatronics.

[10]  Kyoung Kwan Ahn,et al.  Nonlinear PID control to improve the control performance of 2 axes pneumatic artificial muscle manipulator using neural network , 2006 .

[11]  Roger Weber,et al.  Tools for understanding and optimizing robotic gait training. , 2006, Journal of rehabilitation research and development.

[12]  Pierre Lopez,et al.  Modeling and control of McKibben artificial muscle robot actuators , 2000 .

[13]  Martin Buss,et al.  Compliant actuation of rehabilitation robots , 2008, IEEE Robotics & Automation Magazine.

[14]  Yoichi Hori,et al.  Infinity norm approach for precise force control of manipulators driven by bi-articular actuators , 2010, IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society.

[15]  S.K. Agrawal,et al.  Robot assisted gait training with active leg exoskeleton (ALEX) , 2009, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[16]  Shahid Hussain,et al.  Adaptive Impedance Control of a Robotic Orthosis for Gait Rehabilitation , 2013, IEEE Transactions on Cybernetics.

[17]  Kimitaka Nakazawa,et al.  Robotic gait trainer in water: Development of an underwater gait-training orthosis , 2008, Disability and rehabilitation.

[18]  S. Micera,et al.  Design and Evaluation of NEUROBike: A Neurorehabilitative Platform for Bedridden Post-Stroke Patients , 2012, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[19]  R. Müller,et al.  Modulation of leg muscle activity and gait kinematics by walking speed and bodyweight unloading. , 2006, Gait & posture.

[20]  Tomohiko Fujikawa,et al.  Control properties of a two-joint link mechanism equipped with mono- and bi-articular actuators , 2000, Proceedings 9th IEEE International Workshop on Robot and Human Interactive Communication. IEEE RO-MAN 2000 (Cat. No.00TH8499).

[21]  Shahid Hussain,et al.  Robust Nonlinear Control of an Intrinsically Compliant Robotic Gait Training Orthosis , 2013, IEEE Transactions on Systems, Man, and Cybernetics: Systems.

[22]  Paolo Bonato,et al.  Robotic Gait Rehabilitation Trainer , 2014, IEEE/ASME Transactions on Mechatronics.

[23]  R. Riener,et al.  Journal of Neuroengineering and Rehabilitation Open Access Biofeedback for Robotic Gait Rehabilitation , 2022 .

[24]  Tasuku Miyoshi,et al.  Development of gait training system powered by pneumatic actuator like human musculoskeletal system , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[25]  Mohd Azuwan Mat Dzahir,et al.  Development of body weight support gait training system using pneumatic mckibben actuators -Control of Lower Extremity Orthosis- , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[26]  H. van der Kooij,et al.  Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[27]  M. A. M. Dzahir,et al.  Antagonistic mono- and bi-articular pneumatic muscle actuator control for gait training system using contraction model , 2013, 2013 ISSNIP Biosignals and Biorobotics Conference: Biosignals and Robotics for Better and Safer Living (BRC).

[28]  Yoshiyuki Shibata,et al.  Development of body weight support gait training system using antagonistic bi-articular muscle model , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[29]  R. Riener,et al.  A Novel Mechatronic Body Weight Support System , 2006, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[30]  V. Dietz,et al.  Driven gait orthosis for improvement of locomotor training in paraplegic patients , 2001, Spinal Cord.

[31]  Yoichi Hori,et al.  Disturbance rejection improvement in non-redundant robot arms using bi-articular actuators , 2011, 2011 IEEE International Symposium on Industrial Electronics.