Flexible Three-Dimensional Electrochemical Glucose Sensor with Improved Sensitivity Realized in Hybrid Polymer Microelectromechanical Systems Technique

Background: Continuous glucose monitoring for patients with diabetes is of paramount importance to avoid severe health conditions resulting from hypoglycemia or hyperglycemia. Most available methods require an invasive setup and a health care professional. Handheld devices available on the market also require finger pricking for every measurement and do not provide continuous monitoring. Hence, continuous glucose monitoring from human tears using a glucose sensor embedded in a contact lens has been considered as a suitable option. However, the glucose concentration in human tears is very low in comparison with the blood glucose level (1/10–1/40 concentration). We propose a sensor that solves the sensitivity problem in a new way, is flexible, and is constructed onto the oxygen permeable contact lens material. Methods: To achieve such sensitivity while maintaining a small sensor footprint suitable for placement in a contact lens, we increased the active electrode area by using three-dimensional (3-D) electrode micropatterning. Fully flexible 3-D electrodes were realized utilizing ordered arrays of pillars with different shapes and heights. Results: We successfully fabricated square and cylindrical pillars with different height (50, 100, and 200 μm) and uniform metal coverage to realize sensor electrodes. The increased surface area produces high amperometric current that increases sensor sensitivity up to 300% using 200 μ tall square pillars. The sensitivity improvement closely follows the improvement in the surface area of the electrode. Conclusions: The proposed flexible glucose sensors with 3-D microstructure electrodes are more sensitive to lower glucose concentrations and generate higher current signal than conventional glucose sensors.

[1]  Bozena Kaminska,et al.  A sacrificial SU-8 mask for direct metallization on PDMS , 2009 .

[2]  S. J. Kim,et al.  Fabrication of Pillar Shaped Electrode Arrays for Artificial Retinal Implants , 2008, Sensors.

[3]  Bozena Kaminska,et al.  PDMS as a sacrificial substrate for SU-8-based biomedical and microfluidic applications , 2008 .

[4]  Robin Felder,et al.  Flexible Rolled Thick‐Film Miniaturized Flow‐Cell for Minimally Invasive Amperometric Sensing , 2008 .

[5]  Carlos Eduardo Ferrante do Amaral,et al.  Current development in non-invasive glucose monitoring. , 2008, Medical engineering & physics.

[6]  Justin T. Baca,et al.  Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus. , 2007, The ocular surface.

[7]  Justin T. Baca,et al.  Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers. , 2007, Clinical chemistry.

[8]  Akio Funakubo,et al.  A flexible and wearable biosensor for tear glucose measurement , 2007, Biomedical microdevices.

[9]  Matthew A Cooper,et al.  Direct quantification of analyte concentration by resonant acoustic profiling. , 2005, Clinical chemistry.

[10]  L. Colón,et al.  Evaluation of lacrimal fluid as an alternative for monitoring glucose in critically ill patients , 2005, Intensive Care Medicine.

[11]  Adil Denizli,et al.  Molecularly imprinted ligand-exchange recognition assay of glucose by quartz crystal microbalance. , 2005, Biosensors & bioelectronics.

[12]  Peter Herbrechtsmeier,et al.  Clinical trial of a noninvasive contact lens glucose sensor. , 2004, Diabetes technology & therapeutics.

[13]  S. Asher,et al.  Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid. , 2004, Clinical chemistry.

[14]  B. Fink Biochemistry of the Eye, 2nd Ed. , 2004 .

[15]  Kohji Mitsubayashi,et al.  Optical-transparent and flexible glucose sensor with ITO electrode. , 2003, Biosensors & bioelectronics.

[16]  S. Mirov,et al.  Using two discrete frequencies within the middle infrared to quantitatively determine glucose in serum. , 2002, Journal of biomedical optics.

[17]  Binghe Wang,et al.  A detailed examination of boronic acid–diol complexation , 2002 .

[18]  O. Rolinski,et al.  Molecular distribution sensing in a fluorescence resonance energy transfer based affinity assay for glucose. , 2001, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[19]  A. Pirie,et al.  The Biochemistry of the Eye , 1960, Nature.

[20]  C. D. Geddes,et al.  OPHTHALMIC GLUCOSE MONITORING USING DISPOSABLE CONTACT LENSES. , 2005, Reviews in fluorescence.