An optimized three-dimensional linear-electric-field time-of-flight analyzer.

In situ measurements of the dynamics and composition of space plasmas have greatly improved our understanding of the space environment. In particular, mass spectrometers that use a combination of electrostatic analyzers and time-of-flight systems can identify revealing dynamic and compositional characteristics of ions, and thus constrain their sources and the physical processes relevant for their transport. We demonstrate an optimized design of a linear-electric-field time-of-flight technology that can be used to obtain a high signal to noise: ions that follow an energy-isochronous oscillation within the instrument impact an emissive plate and cause secondary electrons to be sent toward the detector, triggering a high-resolution measurement. By focusing these secondary electrons to a central area on a position-sensitive anode, their signals are separated from ions and neutrals that do not experience energy-isochronous motion. Using their impact positions, the high mass resolution measurements are easily distinguished from other signals on the detector, leading to very favorable signal-to-noise ratios. This optimization provides an improvement to existing technologies without increasing the instrument size or complexity, and uses a novel time-of-flight circuit that combines timing and position information from many signals and ions.

[1]  G. Gloeckler,et al.  New high-resolution electrostatic ion mass analyzer using time of flight , 1990 .

[2]  J. Nordholt,et al.  Linear electric field mass analysis: a technique for three-dimensional high mass resolution space plasma composition measurements. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[3]  Joseph E. Borovsky,et al.  Measurement techniques in space plasmas : particles , 1998 .

[4]  R. Wiens,et al.  Deep Space 1 encounter with Comet 19P/Borrelly: Ion composition measurements by the PEPE mass spectrometer , 2003 .

[5]  M. Grande,et al.  Cassini Plasma Spectrometer Investigation , 2004 .

[6]  A. Scharmann,et al.  Ion induced electron emission from metal surfaces , 1981 .

[7]  J. Nordholt,et al.  New approach to 3-D, high sensitivity, high mass resolution space plasma composition measurements , 1990 .

[8]  B. Barraclough,et al.  Ultrathin foils used for low-energy neutral atom imaging of the terrestrial magnetosphere , 1993 .

[9]  M. L. Lampton,et al.  Stacked orthogonal serpentine delay lines with vias for two-dimensional microchannel plate readout , 2000 .

[10]  J. Ziegler,et al.  SRIM – The stopping and range of ions in matter (2010) , 2010 .

[11]  E. Möbius,et al.  High resolution isochronous mass spectrometer for space plasma applications , 1995 .

[12]  B. Barraclough,et al.  Shell effects observed in exit charge state distribution of 1–30 keV atomic projectiles transiting ultrathin carbon foils , 1993 .

[13]  T. Mukai,et al.  Development of an ion energy mass spectrometer for application on board three-axis stabilized spacecraft , 2005 .

[14]  E. Möbius,et al.  High mass resolution isochronous time-of-flight spectrograph for three-dimensional space plasma measurements , 1990 .

[15]  J. Nordholt,et al.  Plasma Experiment for Planetary Exploration (PEPE) , 2007 .

[16]  R. Baragiola Principles and mechanisms of ion induced electron emission , 1993 .

[17]  W. I. Axford,et al.  CELIAS - Charge, Element and Isotope Analysis System for SOHO , 1995 .