Advanced System Monitoring with Phasor Measurements

Phasor Measurement Units (PMUs) are widely acknowledged as one of the most promising developments in the field of real-time monitoring of power systems. By aligning the time stamps of voltage and current phasor measurements that are consistent with Coordinated Universal Time (UTC), a coherent picture of the power system state can be achieved through either direct measurements or simple linear calculations. With the growing number of PMUs planned for installation in the near future, both utilities and research institutions are looking for the best solutions to the placement of units as well as to the applications that make the most of phasor measurements. This dissertation explores a method for optimal PMU placement as well as two applications of synchronized phasor measurements in state estimation. The pre-processing PMU placement method prepares the system data for placement optimization and reduces the size of the optimization problem. It is adaptive to most of the optimal placement methods and can save a large amount of computational effort. Depth of un-observability is one of the criteria to allow the most benefit out of a staged placement of the units. PMUs installed in the system provide synchronized phasor measurements that are highly beneficial to power system state estimations. Two related applications are proposed in the dissertation. First, a post-processing inclusion of phasor measurements in state estimators is introduced. This method avoids the revision of the existing estimators and is able to realize similar results as mixing phasor data with traditional SCADA with a linear afterwards step. The second application is a method to

[1]  M. M. Adibi,et al.  Integration of remote measurement calibration with state estimation-a feasibility study , 1992 .

[2]  A. Abur,et al.  Observability analysis and measurement placement for systems with PMUs , 2004, IEEE PES Power Systems Conference and Exposition, 2004..

[3]  A.G. Phadke,et al.  HISTORY AND APPLICATIONS OF PHASOR MEASUREMENTS , 2006, 2006 IEEE PES Power Systems Conference and Exposition.

[4]  Ali Abur,et al.  Optimal Placement of Phasor Measurement Units for State Estimation , 2005 .

[5]  S. Mokhtari,et al.  Implementation of phasor measurements in state estimator at Sevillana de Electricidad , 1995, Proceedings of Power Industry Computer Applications Conference.

[6]  J. Thorp,et al.  A New Measurement Technique for Tracking Voltage Phasors, Local System Frequency, and Rate of Change of Frequency , 1983, IEEE Transactions on Power Apparatus and Systems.

[7]  Fred C. Schweppe,et al.  Power System Static-State Estimation, Part I: Exact Model , 1970 .

[8]  Warren H. Cook,et al.  - Instrument Transformers , 1970, The Electric Power Engineering Handbook - Five Volume Set.

[9]  A. P. Sakis Meliopoulos,et al.  Advances in the SuperCalibrator Concept - Practical Implementations , 2007, 2007 40th Annual Hawaii International Conference on System Sciences (HICSS'07).

[10]  T.W. Cease,et al.  Real-time monitoring of the TVA power system , 1994, IEEE Computer Applications in Power.

[11]  A. P. Sakis Meliopoulos,et al.  GPS-Synchronized Data Acquisition: Technology Assessment and Research Issues , 2006, Proceedings of the 39th Annual Hawaii International Conference on System Sciences (HICSS'06).

[12]  Claude Lemaréchal,et al.  Lagrangian Relaxation , 2000, Computational Combinatorial Optimization.

[13]  A. Monticelli,et al.  Multiple Bad Data Detectability and Identifiability: A Geometric Approach , 1986, IEEE Transactions on Power Delivery.

[14]  Wang Peng,et al.  Comparison of several PMU placement algorithms for state estimation , 2004 .

[15]  James H. Harlow,et al.  Electric Power Transformer Engineering , 2003 .

[16]  Garng Huang,et al.  Transaction based power flow analysis for transmission utilization allocation , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[17]  A. G. Expósito,et al.  Power system state estimation : theory and implementation , 2004 .

[18]  A. Abur,et al.  Combined state estimation and measurement calibration , 2005, IEEE Transactions on Power Systems.

[19]  P. Komarnicki,et al.  PMU placement method based on decoupled newton power flow and sensitivity analysis , 2007, 2007 9th International Conference on Electrical Power Quality and Utilisation.

[20]  A.G. Phadke,et al.  Phasor measurement unit placement techniques for complete and incomplete observability , 2005, IEEE Transactions on Power Delivery.

[21]  D. Kirschen,et al.  Why Investments Do Not Prevent Blackouts , 2004 .

[22]  Fred C. Schweppe,et al.  Power System Static-State Estimation, Part III: Implementation , 1970 .

[23]  M. M. Adibi,et al.  Remote Measurement Calibration , 1986, IEEE Transactions on Power Systems.

[24]  A.G. Phadke,et al.  Synchronized phasor measurements in power systems , 1993, IEEE Computer Applications in Power.

[25]  M. M. Adibi,et al.  Minimization of uncertainties in analog measurements for use in state estimation , 1990 .

[26]  A. Abur,et al.  Effect of Phasor Measurements on the Choice of Reference Bus for State Estimation , 2007, 2007 IEEE Power Engineering Society General Meeting.

[27]  P. Myrda,et al.  Delivering accurate and timely data to all , 2007, IEEE Power and Energy Magazine.

[28]  William F. Tinney,et al.  State Estimation in Power Systems Part II: Implementation and Applications , 1970 .

[29]  A.G. Phadke,et al.  An Alternative for Including Phasor Measurements in State Estimators , 2006, IEEE Transactions on Power Systems.

[30]  John Peschon,et al.  State Estimation in Power Systems Part I: Theory and Feasibility , 1970 .

[31]  Fred W. Glover,et al.  Technical Note - Converting the 0-1 Polynomial Programming Problem to a 0-1 Linear Program , 1974, Oper. Res..

[32]  R. Adapa,et al.  Phasor measurement placement for voltage stability analysis of power systems , 1990, 29th IEEE Conference on Decision and Control.

[33]  Rastko Zivanovic,et al.  Implementation of PMU technology in state estimation: an overview , 1996, Proceedings of IEEE. AFRICON '96.

[34]  W. Hubbi Computational method for remote meter calibration in power systems , 1996 .

[35]  J.F. Dopazo,et al.  Implementation of the AEP real-time monitoring system , 1976, IEEE Transactions on Power Apparatus and Systems.

[36]  Fred C. Schweppe,et al.  Power System Static-State Estimation, Part II: Approximate Model , 1970 .

[37]  Arun G. Phadke,et al.  Synchronized phasor measurements-a historical overview , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[38]  S.A. Soman,et al.  Optimal Multistage Scheduling of PMU Placement: An ILP Approach , 2008, IEEE Transactions on Power Delivery.

[39]  T. Baldwin,et al.  Power system observability with minimal phasor measurement placement , 1993 .

[40]  J. Thorp,et al.  Real Time Voltage-Phasor Measurements for Static State Estimation , 1985, IEEE Power Engineering Review.

[41]  Fan Zhang,et al.  Transmission level instrument transformers and transient event recorders characterization for harmonic measurements , 1993 .