Hydrodynamic simulation of cell docking in microfluidic channels with different dam structures.

The immobilization of biological cells in micro-devices requires high efficiency and easy control while maintaining cell viability. One approach for cell immobilization is to utilize constriction structures such as dams to trap cells in microfluidics. In this paper, we present a comprehensive hydrodynamic analysis of two different types of constriction structures for cell immobilization: dams either in perpendicular or in parallel to the main flow route. Various structural models and experimental conditions were compared for cell docking and alignment, and the pressure and velocity profiles of the flow in the micro-channels and the hydrodynamic force and shear stress on the docked cells were calculated based on fluid dynamic theory and numerical simulation. The effects of the dam structures and cell docking on the flow properties, the transportation efficiency, and the induced stress on the docked cells were analyzed. Improved hydraulic pressure profiles in the auxiliary inlets were discussed for the modulation of the flow characteristics and attenuation of hydrodynamic forces exerted on the cells. Furthermore, a new design combining the advantages of perpendicular and parallel dam structures was proposed for cell-based microfluidics.

[1]  H. Carlson,et al.  Sorting of White Blood Cells in a Lattice , 1997 .

[2]  G. Gradl,et al.  A 3-D microelectrode system for handling and caging single cells and particles , 1999 .

[3]  Paul C. H. Li,et al.  Transport, manipulation, and reaction of biological cells on-chip using electrokinetic effects. , 1997, Analytical chemistry.

[4]  Mengsu Yang,et al.  Cell docking and on-chip monitoring of cellular reactions with a controlled concentration gradient on a microfluidic device. , 2002, Analytical chemistry.

[5]  S G Shirley,et al.  Dielectrophoretic sorting of particles and cells in a microsystem. , 1998, Analytical chemistry.

[6]  B D DeBusschere,et al.  Portable cell-based biosensor system using integrated CMOS cell-cartridges. , 2001, Biosensors & bioelectronics.

[7]  H. Andersson,et al.  Microfluidic devices for cellomics: a review , 2003 .

[8]  J. Chalmers,et al.  Cell damage of microcarrier cultures as a function of local energy dissipation created by a rapid extensional flow. , 2000, Biotechnology and bioengineering.

[9]  Jeffrey J. Chalmers,et al.  Computer simulations of the rupture of a gas bubble at a gas—liquid interface and its implications in animal cell damage , 1994 .

[10]  L V McIntire,et al.  Fluid flow stimulates tissue plasminogen activator secretion by cultured human endothelial cells. , 1989, Science.

[11]  C. S. Chen,et al.  Geometric control of cell life and death. , 1997, Science.

[12]  D P Gaver,et al.  A theoretical model study of the influence of fluid stresses on a cell adhering to a microchannel wall. , 1998, Biophysical journal.

[13]  J. Chalmers,et al.  Fabrication and use of a transient contractional flow device to quantify the sensitivity of mammalian and insect cells to hydrodynamic forces , 2002, Biotechnology and bioengineering.

[14]  L V McIntire,et al.  Hydrodynamic shear stress and mass transport modulation of endothelial cell metabolism , 1991, Biotechnology and bioengineering.

[15]  S L Diamond,et al.  Fluid shear stress induction of the transcriptional activator c‐fos in human and bovine endothelial cells, HeLa, and Chinese hamster ovary cells , 2000, Biotechnology and bioengineering.

[16]  M S Croughan,et al.  Growth and death in overagitated microcarrier cell cultures , 1989, Biotechnology and bioengineering.

[17]  Luc J. Bousse Whole cell biosensors , 1996 .

[18]  S A Sundberg,et al.  High-throughput and ultra-high-throughput screening: solution- and cell-based approaches. , 2000, Current opinion in biotechnology.

[19]  George M. Whitesides,et al.  Laminar flows: Subcellular positioning of small molecules , 2001, Nature.