Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic models.

Measurements and different analyses of dental casts are essential for precise diagnosis of an orthodontic case. At present, virtual computerized models, such as OrthoCAD, are available for clinicians, supplemented by dedicated software for performing needed measurements on them. The purpose of this study was to test the accuracy of measuring casts with the aid of calipers or OrthoCAD and compare these two techniques. Twenty setups using artificial teeth corresponding to various malocclusions were created. Impressions were taken of them, providing 20 plaster and 20 virtual orthodontic models. Measurements of mesiodistal tooth dimension as well as intercanine and intermolar width were made on both. Additionally, values of tooth size were calculated from the isolated artificial teeth removed from the setups and of arch width from the existing setups. The resulting values were compared by the use of nonparametric statistics, and methods' errors were also calculated. Results showed the methods being highly valid and reproducible for both tooth size and arch width. For the tested clinically applicable methods, measurement with digital calipers on plaster models showed the highest accuracy and reproducibility, closely followed by OrthoCAD. Digital calipers seem to be a more suitable instrument for scientific work. However, OrthoCAD's accuracy is clinically acceptable, and most likely, considering its present advantages and future possibilities, the examined or an equivalent 3D virtual models' procedure would become the standard for orthodontic clinical use.

[1]  M S Cooke,et al.  Space analysis: a comparison between sonic digitization (DigiGraph Workstation) and the digital caliper. , 1998, European journal of orthodontics.

[2]  T J Marcel,et al.  Three-dimensional on-screen virtual models. , 2001, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[3]  S Wynchank,et al.  A critical comparison of three methods for measuring dental models. , 1991, The Journal of the Dental Association of South Africa = Die Tydskrif van die Tandheelkundige Vereniging van Suid-Afrika.

[4]  H Rydén,et al.  Tooth position measurements on dental casts using holographic images. , 1982, American journal of orthodontics.

[5]  M N Lowey,et al.  The Development of a New Method of Cephalometric and Study Cast Mensuration with a Computer Controlled, Video Image Capture System. Part II: Study Cast Mensuration , 1993, British journal of orthodontics.

[6]  W. Stuart Hunter,et al.  Errors and Discrepancies in Measurement of Tooth Size , 1960, Journal of dental research.

[7]  W. Wiltshire,et al.  Manual and computer-aided space analysis: a comparative study. , 1997, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[8]  W. C. Shellhart,et al.  Reliability of the Bolton tooth-size analysis when applied to crowded dentitions. , 2009, The Angle orthodontist.

[9]  A Romeo,et al.  Holograms in orthodontics: a universal system for the production, development, and illumination of holograms for the storage and analysis of dental casts. , 1995, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[10]  A Jäger,et al.  Construction and testing of a computer-based intraoral laser scanner for determining tooth positions. , 2000, Medical engineering & physics.

[11]  T Kuroda,et al.  A 3D computer-aided design system applied to diagnosis and treatment planning in orthodontics and orthognathic surgery. , 1999, European journal of orthodontics.

[12]  Wayne A. Bolton,et al.  The clinical application of a tooth-size analysis , 1962 .

[13]  Mariano Alcañiz Raya,et al.  An advanced system for the simulation and planning of orthodontic treatment , 1998, Medical Image Anal..

[14]  T Kuroda,et al.  Three-dimensional dental cast analyzing system using laser scanning. , 1996, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[15]  J. Fischer,et al.  A comparison of 3 computerized Bolton tooth-size analyses with a commonly used method. , 2009, The Angle orthodontist.

[16]  M Champagne,et al.  Reliability of measurements from photocopies of study models. , 1992, Journal of clinical orthodontics : JCO.

[17]  T Sohmura,et al.  Development of the computerized dental cast form analyzing system--three dimensional diagnosis of dental arch form and the investigation of measuring condition. , 1997, Dental materials journal.

[18]  The Reader's Corner , 1951 .

[19]  L. Walford,et al.  Statistical Methods for Medical and Biological Students , 1940, The Indian Medical Gazette.

[20]  J Takahashi,et al.  Use of an ultrahigh-speed laser scanner for constructing three-dimensional shapes of dentition and occlusion. , 2000, The Journal of prosthetic dentistry.

[21]  W J Houston,et al.  The analysis of errors in orthodontic measurements. , 1983, American journal of orthodontics.

[22]  T. Mikami,et al.  Measurements of dental cast profile and three-dimensional tooth movement during orthodontic treatment , 1991, IEEE Transactions on Biomedical Engineering.

[23]  R. Binder,et al.  Clinical evaluation of tooth-size discrepancy. , 1998, Journal of clinical orthodontics : JCO.

[24]  T Mikami,et al.  Optical measurement of dental cast profile and application to analysis of three-dimensional tooth movement in orthodontics. , 1989, Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering.