Assessment of Orbital Computed Tomography (CT) Imaging Biomarkers in Patients with Thyroid Eye Disease

To understand potential orbital biomarkers generated from computed tomography (CT) imaging in patients with thyroid eye disease. This is a retrospective cohort study. From a database of an ongoing thyroid eye disease research study at our institution, we identified 85 subjects who had both clinical examination and laboratory records supporting the diagnosis of thyroid eye disease and concurrent imaging prior to any medical or surgical intervention. Patients were excluded if imaging quality or type was not amenable to segmentation. The images of 170 orbits were analyzed with the developed automated segmentation tool. The main outcome measure was to cross 25 CT structural metrics for each eye with nine clinical markers using a Kendall rank correlation test to identify significant relationships. The Kendall rank correlation test between automatically calculated CT metrics and clinical data demonstrated numerous correlations. Extraocular rectus muscle metrics, such as the average diameter of the superior, medial, and lateral rectus muscles, showed a strong correlation (p < 0.05) with loss of visual acuity and presence of ocular motility defects. Hertel measurements demonstrated a strong correlation (p < 0.05) with volumetric measurements of the optic nerve and other orbital metrics such as the crowding index and proptosis. Optic neuropathy was strongly correlated (p < 0.05) with an increase in the maximum diameter of the superior muscle. This novel method of automated imaging metrics may provide objective, rapid clinical information. This data may be useful for appreciation of severity of thyroid eye disease and recognition of risk factors of visual impairment from dysthyroid optic neuropathy from CT imaging.

[1]  S C Werner,et al.  Classification of the eye changes of Graves' disease. , 1969, American journal of ophthalmology.

[2]  P. Toft,et al.  Orbital Volumetry in Graves' Orbitopathy: Muscle and Fat Involvement in relation to Dysthyroid Optic Neuropathy , 2014, ISRN ophthalmology.

[3]  B. Hershey,et al.  High-resolution CT of lesions of the optic nerve. , 1983, AJR. American journal of roentgenology.

[4]  Michele Marinò,et al.  Clinical features of dysthyroid optic neuropathy: a European Group on Graves’ Orbitopathy (EUGOGO) survey , 2006, British Journal of Ophthalmology.

[5]  S. Kelly,et al.  Cigarette smoking and thyroid eye disease: a systematic review , 2007, Eye.

[6]  J. Lazarus,et al.  Epidemiology of Graves' orbitopathy (GO) and relationship with thyroid disease. , 2012, Best practice & research. Clinical endocrinology & metabolism.

[7]  E Bradley Strong,et al.  Reply Re: "Computer-aided analysis of orbital volume: a novel technique". , 2014, Ophthalmic plastic and reconstructive surgery.

[8]  I B HALES,et al.  Ocular changes in Graves' disease. A long-term follow-up study. , 1960, The Quarterly journal of medicine.

[9]  Michael Brady,et al.  MRF-Based Deformable Registration and Ventilation Estimation of Lung CT , 2013, IEEE Transactions on Medical Imaging.

[10]  J. Falko,et al.  Ocular changes in Graves' disease. , 1983, The Ohio State medical journal.

[11]  Holly Bridge,et al.  Is orbital volume associated with eyeball and visual cortex volume in humans? , 2013, Annals of human biology.

[12]  M. Mukaka,et al.  Statistics corner: A guide to appropriate use of correlation coefficient in medical research. , 2012, Malawi medical journal : the journal of Medical Association of Malawi.

[13]  Peter W Potgieser,et al.  Re: "Computer-aided analysis of orbital volume: a novel technique". , 2014, Ophthalmic plastic and reconstructive surgery.

[14]  L Koornneef,et al.  Clinical criteria for the assessment of disease activity in Graves' ophthalmopathy: a novel approach. , 1989, The British journal of ophthalmology.

[15]  Z. Karányi,et al.  Using morphologic parameters of extraocular muscles for diagnosis and follow-up of Graves' ophthalmopathy: diameters, areas, or volumes? , 2002, AJR. American journal of roentgenology.

[16]  D. Graeb,et al.  Graves orbitopathy: correlation of CT and clinical findings. , 1990, Radiology.

[17]  L. Cocchiarella,et al.  Guides to the evaluation of permanent impairment , 2000 .

[18]  Suzana Matayoshi,et al.  Predicting dysthyroid optic neuropathy using computed tomography volumetric analyses of orbital structures , 2012, Clinics.

[19]  Jack Rootman,et al.  Quantitative computed tomographic predictors of compressive optic neuropathy in patients with thyroid orbitopathy: a volumetric analysis. , 2012, Ophthalmology.

[20]  Michael C Hurley,et al.  Clinical and soft-tissue computed tomographic predictors of dysthyroid optic neuropathy: refinement of the constellation of findings at presentation. , 2011, Archives of ophthalmology.

[21]  A E Rosenbaum,et al.  Apical optic nerve compression of dysthyroid optic neuropathy on computed tomography. , 1981, Archives of ophthalmology.

[22]  S M Drance,et al.  Dysthyroid optic neuropathy. The crowded orbital apex syndrome. , 1988, Ophthalmology.

[23]  M. Ariyurek,et al.  Normative measurements of orbital structures using CT. , 1998, AJR. American journal of roentgenology.

[24]  R M Burde,et al.  Optic nerve dysfunction in thyroid eye disease: CT. , 1988, Radiology.

[25]  M. Monteiro,et al.  Quantification of Orbital Apex Crowding for Screening of Dysthyroid Optic Neuropathy Using Multidetector CT , 2012, American Journal of Neuroradiology.

[26]  H. Abdi The Kendall Rank Correlation Coefficient , 2007 .

[27]  Timothy R. Olsen,et al.  The Extensible Neuroimaging Archive Toolkit: an informatics platform for managing, exploring, and sharing neuroimaging data. , 2007, Neuroinformatics.

[28]  J. Giaconi,et al.  CT Scan Evidence of Dysthyroid Optic Neuropathy , 2002, Ophthalmic plastic and reconstructive surgery.

[29]  E. Gebrim,et al.  Diagnostic Ability Of Barrett’s Index to Detect Dysthyroid Optic Neuropathy Using Multidetector Computed Tomography , 2008, Clinics.

[30]  Daniel Fabbri,et al.  Structural functional associations of the orbit in thyroid eye disease: Kalman filters to track extraocular rectal muscles , 2016, SPIE Medical Imaging.

[31]  J. Perry,et al.  Superior Ophthalmic Vein Enlargement and Increased Muscle Index in Dysthyroid Optic Neuropathy , 2013, Ophthalmic plastic and reconstructive surgery.

[32]  S. Feldon,et al.  Graves' ophthalmopathy: I. Simple CT estimates of extraocular muscle volume. , 1988, The British journal of ophthalmology.

[33]  S. Feldon,et al.  Graves' ophthalmopathy: II. Correlation of clinical signs with measures derived from computed tomography. , 1988, The British journal of ophthalmology.

[34]  Benjamin N. Conrad,et al.  Vanderbilt University Institute of Imaging Science Center for Computational Imaging XNAT: A multimodal data archive and processing environment , 2016, NeuroImage.

[35]  S. Feldon,et al.  Clinical significance of extraocular muscle volumes in Graves' ophthalmopathy: a quantitative computed tomography study. , 1982, Archives of ophthalmology.

[36]  L. M. Wellock Guides to the Evaluation of Permanent Impairment , 1972 .

[37]  G. Kahaly,et al.  Neuroimaging of Graves' orbitopathy. , 2012, Best practice & research. Clinical endocrinology & metabolism.

[38]  S. Feldon,et al.  Quantitative computed tomography of Graves' ophthalmopathy. Extraocular muscle and orbital fat in development of optic neuropathy. , 1985, Archives of ophthalmology.

[39]  Robert B. Wilkins,et al.  Dysthyroid Optic Neuropathy: The Crowded Orbital Apex Syndrome. By Janet M. Neigel, Jack Rootman, Rod I. Belkin, Robert A. Nugent, Stephen M. Drance, Craig W. Beattie, and John A. Spinelli. Ophthalmology 1988;95, 1515–21 , 1989 .

[40]  R L Dallow,et al.  Orbital computed tomographic characteristics of globe subluxation in thyroid orbitopathy. , 1998, Ophthalmology.

[41]  S. Fook-Chong,et al.  Graves Ophthalmopathy: The Bony Orbit in Optic Neuropathy, Its Apical Angular Capacity, and Impact on Prediction of Risk , 2009, American Journal of Neuroradiology.

[42]  Brian B. Avants,et al.  Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brain , 2008, Medical Image Anal..

[43]  Bennett A Landman,et al.  Non-local statistical label fusion for multi-atlas segmentation , 2013, Medical Image Anal..

[44]  G. Lennerstrand,et al.  MRI measurements of normal extraocular muscles and other orbital structures , 2000, Graefe's Archive for Clinical and Experimental Ophthalmology.